Please position the pump on solid ground. Avoid placing it on lose stones or sand. When positioning the pump,
please do make sure that the pump cannot tip over or sink into the ground with its intake openings (6). The
penetration of sand, mud or comparable matters is to be avoided.
To position, lift up or carry the pump, please use only the carrying handle. If required for lowering or raising the
pump, you may connect a suitable lowering rope to the carrying handle. In no case must the pressure hose, the
mains cable or the cable of the floating switch be used to position, to lift up or to carry the pump.
6. Electrical connection
The unit is equipped with a mains connection cable and a mains plug. It must only be replaced by qualified staff to
avoid any danger. Please do not use the mains connection cable to carry the pump, and do not use this cable to
pull off the plug from the socket, either. Protect the mains connection cable and mains plug from heat, oil or sharp
edges.
The values stated in the technical details have to correspond to the mains voltage. The person
responsible for the installation has to make sure that the electrical connection is earthed in
compliance with the applicable standards.
The electrical connection has to be equipped with a highly sensitive residual current circuit-
breaker (FI switch): ∆ = 30 mA (DIN VDE 0100-739).
Only use an extension cable with a cable section (3 x 1.0 mm²) and rubber sheath which at
least corresponds to that of the unit's own connection cable (see "Technical data", cable type)
and which is labeled with the relevant abbreviation according to the VDE (German Association
for Electrical, Electronic & Information Technologies). The mains plug and other connections
must be splash proof.
7. Putting into operation
Nobody must be in the water while the pump is running.
The pump must only be operated in the performance range indicated on the type plate.
Dry-running - i.e. operating the pump without discharging water - is to be avoided since the
absence of water may cause the pump to run hot. This may cause considerable damage on
the device.
Please make sure that the electrical plug connections are in the flood-proof area.
As long as the device is connected to the electrical mains, one must never reach with one’s
hands into the opening of the pump.
Please inspect the pump visually prior to each use. This applies in particular to the mains connection line and the
mains plug. Make sure that all screws are firmly tightened, and verify the perfect condition of all connections. A
damaged pump must not be used. In any case of damage, the pump has to be inspected by qualified service
staff.
Each time the pump is put into operation, please make sure that the pump is set up securely and firmly standing.
To put the unit into operation, please plug the mains plugs into a 230V AC socket. If the water level has reached
or exceeded the cut-in level, the pump will start to run immediately.
To stop the operation of the pump, please pull the mains plug off the socket.
The electrical pumps of the T.I.P. EXTREMA series are equipped with an integrated thermal motor protection
feature. In the case of overload, the motor will switch off independently and on again after cooling down. For
possible causes and their elimination, please refer to the “Maintenance and troubleshooting” section. Please note
that the pump can only be operated with liquids > 50°C for a short period of time (see Technical data).
8. Maintenance and troubleshooting
Prior to carrying out any maintenance work, the pump must be separated from the electrical
mains. If you fail to separate the unit from mains, there is a risk of an inadvertent start of the
pump.
11

Chat with your T.I.P. Extrema 300/10 IX manual using AI

Get instant AI answers from your T.I.P. Extrema 300/10 IX manual

Ask anything about the T.I.P. Extrema 300/10 IX. Answers come from this manual, with the pages they are based on.

Extrema 300/10 IX Maintenance Schedule

Before each use
Visual inspection

Inspect the pump visually before each use, especially the mains cable and plug. Ensure all screws are tight and connections are in perfect condition.

Show in the manual (page 12)
As needed
Clean hydraulic parts

Clean the hydraulic part from sediments by counter-flushing with clear water through the pressure port. Remove tenacious dirt by loosening screws on the pump foot.

Show in the manual (page 13)
When freezing temperatures occur
Drain and store pump

Remove the pump from the liquid and drain it completely to prevent damage from freezing. Store in a dry, frost-protected place.

Show in the manual (page 13)
M: QW-35-FL

Ask a Question

0/1000

Do you recommend Extrema 300/10 IX?

Yes No
0
User Pic

Peter Schneider

10 months ago

Is the delivery really fast, and does the pump arrive in good condition (packaging, contact), even if I have not used it yet?

0
User Pic

Manual.ly

10 months ago

Based on customer feedback, shipping is very fast and the pump arrives well handled. Reviewers reported everything was perfect on delivery and praised the contact/communication. In at least one case, the pump had not been put to use yet because of an ongoing situation, but the delivery and condition were still described as excellent. If you receive your order damaged or incomplete, please contact support right away so we can help with the next steps.

M: OA-GPT-5-NAN
M: OA-GPT-5-NAN

Frequently Asked Questions

A

It handles clear and dirty water containing solids up to 40 mm, suitable for pond, tank and pit drainage and emergency flood pumping. It is not suitable for saltwater, fecal waste, flammable, corrosive, explosive or other hazardous liquids.

Is this answer helpful?

A

Continuous operation is rated up to 50 °C. The pump can operate short-term with liquid temperatures up to 95 °C for a maximum of 4 minutes, after which thermal protection will shut the motor off to cool.

Is this answer helpful?

A

The built-in float switch automatically starts and stops the pump at adjustable cut-in and cut-out levels by changing the free cable length in the cable guide. It can be locked for manual operation, but manual use requires constant supervision to prevent dry running.

Is this answer helpful?

A

Use a properly earthed 230 V AC supply with a residual current device (RCD) ≤30 mA. The pump has a 10 m H07RN-F cable; any cable or plug replacement must be performed by qualified personnel and extension cables must match the cable specification.

Is this answer helpful?

A

Under normal use the pump is largely maintenance-free. Periodically clear the intake and discharge of debris, counter-flush deposits through the discharge port, and remove the pump foot to clean stubborn dirt. Always disconnect power before maintenance and store the pump drained and frost-free.

Is this answer helpful?

A

Check for clogged intake or discharge lines, trapped air in the pump (start several times to purge), ensure minimum suction level is met and the float switch is set and free-moving, and inspect any check valve for blockage.

Is this answer helpful?

A

Private end-users have a two-year warranty against material and workmanship defects. It excludes normal wear parts (impeller, seals), damage from misuse, improper repairs, external events, and noncompliant installations. Proof of purchase is required for claims.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • High flow rate up to 19,500 L/h with 1,200 W motor for efficient drainage
  • Adjustable float switch for automatic and manual operation (with supervision)
  • IPX8 submersible rating and 10 m cable for flexible installations
  • Short-term high-temperature handling up to 95 °C (max 4 minutes)
  • Integrated thermal motor protection and clear troubleshooting guidance
VS

Disadvantages

  • Not suitable for saltwater, fecal matter, flammable or corrosive liquids
  • Max solid size 40 mm; abrasive particles accelerate wear
  • Short high-temperature allowance (4 minutes) limits prolonged hot-liquid use
  • Requires RCD (≤30 mA) and proper earthing; needs qualified work for cable replacement
  • Not intended for commercial/industrial use or potable water systems
M: OA-GPT-5-NAN

Product Specification

Power

1200W

Flow rate

5,151.33 gal/h

Delivery height

34.45 ft

Submersion depth

22.97 ft

Pressure

15.23 psi

Hose connection

1 1/2"

Special features

without tank

Cable length

32.81 ft

Weight

22.49 lb

M: OA-GPT-54-NAN

Product Description

T.I.P. Extrema 300/10 IX Electric dirty water submersible pump Manual

The T.I.P. Extrema 300/10 IX is a heavy-duty dirty-water submersible pump designed for reliable domestic drainage and temporary or fixed installations. Built with modern pump technology and robust electrical and mechanical components, this 1,200 W pump handles solids up to 40 mm and delivers up to 19,500 L/h, reaching a maximum head of 10.5 m. It’s intended for non-commercial use: emptying ponds, tanks, wastewater pits and emergency flood drainage. The unit is IPX8 rated for submersion, has a 10 m H07RN-F power cable, and a 1½" male pressure outlet (47.80 mm) for flexible or rigid discharge lines.

Key features and operation

The pump includes an adjustable float switch for automatic on/off control and can be set to manual operation by locking the float—though manual use requires supervision to avoid dry running. A short-term high-temperature capability allows operation up to 95 °C for a maximum of 4 minutes; normal continuous operation is limited to 50 °C. The pump has integrated thermal motor protection that trips under overload and restarts after cooling. Minimum self-priming and suction levels are specified to avoid loss of performance; maximum immersion depth is 7 m.

Installation emphasizes leak-free connections, frost protection, secure positioning on firm ground (not loose stones or sand), and protecting power connections from flooding. For stationary installs rigid piping with a non-return valve and shut-off valve is recommended to avoid backflow and simplify maintenance. Use an RCD (residual current device) with ≤30 mA trip current, and ensure correct earthing and supply voltage per the nameplate.

Maintenance is minimal when used properly: periodic cleaning or counter-flushing through the discharge port can remove deposits; the pump foot can be removed to clear stubborn debris. Avoid sand and abrasive solids where possible to reduce wear. In case of faults, the manual lists troubleshooting steps (no power, blocked impeller, air in pump body, float-switch issues, thermal trips, worn impeller) and advises contacting authorized service for repairs beyond basic clearing and checks. Store the pump frost-free and fully drained when not in use.

Warranty, spare parts and service details: private end-users receive a two-year warranty against material and workmanship defects (subject to terms and exclusions). Spare parts and ordering are available via the manufacturer’s website and customer service; service contact information and instructions for warranty claims are provided.

Notes

  • Intended for domestic use only; not for potable public water networks, swimming pools, aquariums, saltwater, fecal waste or hazardous fluids.
  • Use appropriate hoses/pipes sized at least to the pump outlet to avoid flow loss.
  • Observe the specified maximum start frequency (30 starts/hour) and the thermal protection behavior with hot liquids.
  • Keep the pump and cables away from children and ensure RCD protection.