5. Installation
5.1. General installation information
During the entire process of installation, the device must not be connected to the electrical
mains.
The pump and the entire connection system have to be protected from frost.
All connection lines have to be perfectly tight since leaking lines may affect the performance of the pump and
cause considerable damage. If required, please use a suitable sealant to make the installation airtight.
When tightening threaded connections, please do not apply excessive force which may cause damage.
When laying the connection pipes, you should make sure that the pump is not exposed to any form of weight,
vibration or tension. Moreover, the connection lines must not contain any kinks or an adverse slope.
Please observe the illustrations, too, which are contained as an attachment at the end of the present operating
instructions. The numeric and other details included in brackets below refer to these illustrations.
5.2. Installation of the pressure line
The pressure line conveys the liquids to be discharged from the pump to the point of withdrawal. To avoid
dynamic flow losses, one should use a pressure line having at least the same diameter as the pressure port (1) of
the pump.
The pressure line to be used for this type of application is an appropriate flexible hose - for instance, a specially
designed drainage hose.
5.3. Stationary installation
If the unit is used in a stationary installation, rigid pipes have proven to be the ideal choice for the pressure lines.
In this type of installation, we recommend that you incorporate a check valve (non-return valve) in the pressure
line immediately following the pump outlet so that no liquid will flow back after the pump cuts out. To facilitate
maintenance work, we also recommend the installation of a stop cock valve downstream of the pump and check
valve. This arrangement is beneficial in that closing the stop cock will prevent the pressure line from running dry
after the disassembly of the pump.
5.4. How to set the floating switch
Please make sure that the pump will cut out as soon as the water level decreases and the
floating switch has reached the cut-out level.
Also, it must be made sure that the floating switch can move freely.
In the manual operation mode the pump (with adjusted float switch) must be constantly
monitored to avoid dry running.
The pump is equipped with a floating switch (2) causing the unit to cut in or out automatically as a function of the
water level as soon as the water level has reached, or dropped below, the cut-out level, the pump will cut out.
When the water level reaches or raises above the cut-in level, the pump will resume operation. The cut-in and cut-
out levels can be adjusted by shortening or lengthening the freely movable cable (3) of the floating switch. The
length of the cable can be set at the cable duct (4) located at the carrying handle (5) of the pump. In this regard,
the relevant part is the freely movable part of the cable leading from the cable duct to the floating switch. If this
length increases, the cut-out level will decrease, and the cut-in level will augment. Vice versa, if its length
decreases, the cut-in level will decrease whereas the cut-out level will be raised. Shall the pump continue to suck
beyond the automatic cut-out-level the float switch hast to be operated manually, e.g. by holding it in upright
position. To do this, you must remove the cable of the floating switch from the cable guide (4) at the side. Then
adjust the floating switch to the intended holder (13) underneath the cable guide by sliding the switch vertically
into the holder from above so that the cable pointes downside. Just in this operation mode the min. suction level
given in the technical data chart can be achieved. However, the pump must be constantly monitored to avoid dry
running.
5.5. How to position the pump
When positioning the pump, please make sure that the max. submersion depth indicated in the technical data will
not be exceeded. Likewise, please make sure that the minimum self-priming level is not fallen short of. If
everything is properly set, the water level may decrease down to the minimum suction level once the pump is
operating.
10

Chat with your T.I.P. Extrema 300/10 IX manual using AI

Get instant AI answers from your T.I.P. Extrema 300/10 IX manual

Ask anything about the T.I.P. Extrema 300/10 IX. Answers come from this manual, with the pages they are based on.

Extrema 300/10 IX Maintenance Schedule

Before each use
Visual inspection

Inspect the pump visually before each use, especially the mains cable and plug. Ensure all screws are tight and connections are in perfect condition.

Show in the manual (page 12)
As needed
Clean hydraulic parts

Clean the hydraulic part from sediments by counter-flushing with clear water through the pressure port. Remove tenacious dirt by loosening screws on the pump foot.

Show in the manual (page 13)
When freezing temperatures occur
Drain and store pump

Remove the pump from the liquid and drain it completely to prevent damage from freezing. Store in a dry, frost-protected place.

Show in the manual (page 13)
M: QW-35-FL

Ask a Question

0/1000

Do you recommend Extrema 300/10 IX?

Yes No
0
User Pic

Peter Schneider

10 months ago

Is the delivery really fast, and does the pump arrive in good condition (packaging, contact), even if I have not used it yet?

0
User Pic

Manual.ly

10 months ago

Based on customer feedback, shipping is very fast and the pump arrives well handled. Reviewers reported everything was perfect on delivery and praised the contact/communication. In at least one case, the pump had not been put to use yet because of an ongoing situation, but the delivery and condition were still described as excellent. If you receive your order damaged or incomplete, please contact support right away so we can help with the next steps.

M: OA-GPT-5-NAN
M: OA-GPT-5-NAN

Frequently Asked Questions

A

It handles clear and dirty water containing solids up to 40 mm, suitable for pond, tank and pit drainage and emergency flood pumping. It is not suitable for saltwater, fecal waste, flammable, corrosive, explosive or other hazardous liquids.

Is this answer helpful?

A

Continuous operation is rated up to 50 °C. The pump can operate short-term with liquid temperatures up to 95 °C for a maximum of 4 minutes, after which thermal protection will shut the motor off to cool.

Is this answer helpful?

A

The built-in float switch automatically starts and stops the pump at adjustable cut-in and cut-out levels by changing the free cable length in the cable guide. It can be locked for manual operation, but manual use requires constant supervision to prevent dry running.

Is this answer helpful?

A

Use a properly earthed 230 V AC supply with a residual current device (RCD) ≤30 mA. The pump has a 10 m H07RN-F cable; any cable or plug replacement must be performed by qualified personnel and extension cables must match the cable specification.

Is this answer helpful?

A

Under normal use the pump is largely maintenance-free. Periodically clear the intake and discharge of debris, counter-flush deposits through the discharge port, and remove the pump foot to clean stubborn dirt. Always disconnect power before maintenance and store the pump drained and frost-free.

Is this answer helpful?

A

Check for clogged intake or discharge lines, trapped air in the pump (start several times to purge), ensure minimum suction level is met and the float switch is set and free-moving, and inspect any check valve for blockage.

Is this answer helpful?

A

Private end-users have a two-year warranty against material and workmanship defects. It excludes normal wear parts (impeller, seals), damage from misuse, improper repairs, external events, and noncompliant installations. Proof of purchase is required for claims.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • High flow rate up to 19,500 L/h with 1,200 W motor for efficient drainage
  • Adjustable float switch for automatic and manual operation (with supervision)
  • IPX8 submersible rating and 10 m cable for flexible installations
  • Short-term high-temperature handling up to 95 °C (max 4 minutes)
  • Integrated thermal motor protection and clear troubleshooting guidance
VS

Disadvantages

  • Not suitable for saltwater, fecal matter, flammable or corrosive liquids
  • Max solid size 40 mm; abrasive particles accelerate wear
  • Short high-temperature allowance (4 minutes) limits prolonged hot-liquid use
  • Requires RCD (≤30 mA) and proper earthing; needs qualified work for cable replacement
  • Not intended for commercial/industrial use or potable water systems
M: OA-GPT-5-NAN

Product Specification

Power

1200W

Flow rate

5,151.33 gal/h

Delivery height

34.45 ft

Submersion depth

22.97 ft

Pressure

15.23 psi

Hose connection

1 1/2"

Special features

without tank

Cable length

32.81 ft

Weight

22.49 lb

M: OA-GPT-54-NAN

Product Description

T.I.P. Extrema 300/10 IX Electric dirty water submersible pump Manual

The T.I.P. Extrema 300/10 IX is a heavy-duty dirty-water submersible pump designed for reliable domestic drainage and temporary or fixed installations. Built with modern pump technology and robust electrical and mechanical components, this 1,200 W pump handles solids up to 40 mm and delivers up to 19,500 L/h, reaching a maximum head of 10.5 m. It’s intended for non-commercial use: emptying ponds, tanks, wastewater pits and emergency flood drainage. The unit is IPX8 rated for submersion, has a 10 m H07RN-F power cable, and a 1½" male pressure outlet (47.80 mm) for flexible or rigid discharge lines.

Key features and operation

The pump includes an adjustable float switch for automatic on/off control and can be set to manual operation by locking the float—though manual use requires supervision to avoid dry running. A short-term high-temperature capability allows operation up to 95 °C for a maximum of 4 minutes; normal continuous operation is limited to 50 °C. The pump has integrated thermal motor protection that trips under overload and restarts after cooling. Minimum self-priming and suction levels are specified to avoid loss of performance; maximum immersion depth is 7 m.

Installation emphasizes leak-free connections, frost protection, secure positioning on firm ground (not loose stones or sand), and protecting power connections from flooding. For stationary installs rigid piping with a non-return valve and shut-off valve is recommended to avoid backflow and simplify maintenance. Use an RCD (residual current device) with ≤30 mA trip current, and ensure correct earthing and supply voltage per the nameplate.

Maintenance is minimal when used properly: periodic cleaning or counter-flushing through the discharge port can remove deposits; the pump foot can be removed to clear stubborn debris. Avoid sand and abrasive solids where possible to reduce wear. In case of faults, the manual lists troubleshooting steps (no power, blocked impeller, air in pump body, float-switch issues, thermal trips, worn impeller) and advises contacting authorized service for repairs beyond basic clearing and checks. Store the pump frost-free and fully drained when not in use.

Warranty, spare parts and service details: private end-users receive a two-year warranty against material and workmanship defects (subject to terms and exclusions). Spare parts and ordering are available via the manufacturer’s website and customer service; service contact information and instructions for warranty claims are provided.

Notes

  • Intended for domestic use only; not for potable public water networks, swimming pools, aquariums, saltwater, fecal waste or hazardous fluids.
  • Use appropriate hoses/pipes sized at least to the pump outlet to avoid flow loss.
  • Observe the specified maximum start frequency (30 starts/hour) and the thermal protection behavior with hot liquids.
  • Keep the pump and cables away from children and ensure RCD protection.
M: OA-GPT-5-NAN

© Copyright 2026 Manual.ly