Manual.ly Logo

T.I.P. Extrema 300/10 IX Manual

5.0 · 2 Ratings

PDF manual · 120 Pages

English

M: OA-GPT-5-NAN
page

/ 120

Loading...
14aeb0606fc31b12625c16ae30365a4a4c4b page a
1
Dear customer,
Congratulation for buying your new device from T.I.P.!
Like all our products, this one, too, was developed using the latest technological knowledge. The device was
manufactured and assembled on the basis of state-of-the-art pump technology using most reliable electrical or
electronic components which ensure a high level of quality and a long life of your new product.
Please read through these operating instructions carefully to make sure that you can fully benefit from all features.
Some explanatory illustrations can be found at the end of these operating instructions.
We hope you will enjoy your new device!
Table of contents
1. General safety information ............................................................................................................................. 1
2. Range of use .................................................................................................................................................. 2
3. Technical Data ............................................................................................................................................... 2
4. Scope of delivery ........................................................................................................................................... 2
5. Installation ...................................................................................................................................................... 3
6. Electrical connection ...................................................................................................................................... 4
7. Putting into operation ..................................................................................................................................... 4
8. Maintenance and troubleshooting .................................................................................................................. 4
9. Warranty ........................................................................................................................................................ 6
10. How to order spare parts ................................................................................................................................ 6
11. Service ........................................................................................................................................................... 6
Annex: Illustrations
1. General safety information
Please read through these operating instructions carefully and make yourself conversant with the control
elements and the proper use of this product. We shall not be liable in the case of damage caused as a result of
the nonobservance of instructions and provisions of the present operating instructions. Any damage caused as a
result of the nonobservance of the instructions and regulations contained in the present operating instructions
shall not be covered by the warranty terms. Please keep these operating instructions in a safe place and hand
them on together with the device should you ever dispose of it.
Persons not conversant with the contents of these operating instructions must not
use this device.
The pump must not be used by children.
The pump may be used by persons with reduced physical, sensory or mental
capabilities or lack of experience and / or knowledge if they have been supervised or
instructed in the safe use of the equipment and have understood the resulting
hazards. Children are not allowed to play with the device. Keep the appliance and its
cord out of reach of children.
The pump must not be used when people are in the water.
The pump must be supplied through a residual current device (RCD) having a rated
residual operating current not exceeding 30mA.
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
Notes and instructions with the following symbols require particular attention:
Any nonobservance of these instructions involves the danger of bodily harm to people and/or
damage to property.
Any nonobservance of this instruction bears the risk of an electrical shock which may cause
damage to persons or property.
Please inspect the device for damage occurred during transportation. In case of damage, the retailer has to be
informed immediately, at the latest within 8 days after the date of purchase.
8

Chat with your T.I.P. Extrema 300/10 IX manual using AI

Get instant AI answers from your T.I.P. Extrema 300/10 IX manual

Ask anything about the T.I.P. Extrema 300/10 IX. Answers come from this manual, with the pages they are based on.

Extrema 300/10 IX Maintenance Schedule

Before each use
Visual inspection

Inspect the pump visually before each use, especially the mains cable and plug. Ensure all screws are tight and connections are in perfect condition.

Show in the manual (page 12)
As needed
Clean hydraulic parts

Clean the hydraulic part from sediments by counter-flushing with clear water through the pressure port. Remove tenacious dirt by loosening screws on the pump foot.

Show in the manual (page 13)
When freezing temperatures occur
Drain and store pump

Remove the pump from the liquid and drain it completely to prevent damage from freezing. Store in a dry, frost-protected place.

Show in the manual (page 13)
M: QW-35-FL

Ask a Question

0/1000

Do you recommend Extrema 300/10 IX?

Yes No
0
User Pic

Peter Schneider

10 months ago

Is the delivery really fast, and does the pump arrive in good condition (packaging, contact), even if I have not used it yet?

0
User Pic

Manual.ly

10 months ago

Based on customer feedback, shipping is very fast and the pump arrives well handled. Reviewers reported everything was perfect on delivery and praised the contact/communication. In at least one case, the pump had not been put to use yet because of an ongoing situation, but the delivery and condition were still described as excellent. If you receive your order damaged or incomplete, please contact support right away so we can help with the next steps.

M: OA-GPT-5-NAN
M: OA-GPT-5-NAN

Frequently Asked Questions

A

It handles clear and dirty water containing solids up to 40 mm, suitable for pond, tank and pit drainage and emergency flood pumping. It is not suitable for saltwater, fecal waste, flammable, corrosive, explosive or other hazardous liquids.

Is this answer helpful?

A

Continuous operation is rated up to 50 °C. The pump can operate short-term with liquid temperatures up to 95 °C for a maximum of 4 minutes, after which thermal protection will shut the motor off to cool.

Is this answer helpful?

A

The built-in float switch automatically starts and stops the pump at adjustable cut-in and cut-out levels by changing the free cable length in the cable guide. It can be locked for manual operation, but manual use requires constant supervision to prevent dry running.

Is this answer helpful?

A

Use a properly earthed 230 V AC supply with a residual current device (RCD) ≤30 mA. The pump has a 10 m H07RN-F cable; any cable or plug replacement must be performed by qualified personnel and extension cables must match the cable specification.

Is this answer helpful?

A

Under normal use the pump is largely maintenance-free. Periodically clear the intake and discharge of debris, counter-flush deposits through the discharge port, and remove the pump foot to clean stubborn dirt. Always disconnect power before maintenance and store the pump drained and frost-free.

Is this answer helpful?

A

Check for clogged intake or discharge lines, trapped air in the pump (start several times to purge), ensure minimum suction level is met and the float switch is set and free-moving, and inspect any check valve for blockage.

Is this answer helpful?

A

Private end-users have a two-year warranty against material and workmanship defects. It excludes normal wear parts (impeller, seals), damage from misuse, improper repairs, external events, and noncompliant installations. Proof of purchase is required for claims.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • High flow rate up to 19,500 L/h with 1,200 W motor for efficient drainage
  • Adjustable float switch for automatic and manual operation (with supervision)
  • IPX8 submersible rating and 10 m cable for flexible installations
  • Short-term high-temperature handling up to 95 °C (max 4 minutes)
  • Integrated thermal motor protection and clear troubleshooting guidance
VS

Disadvantages

  • Not suitable for saltwater, fecal matter, flammable or corrosive liquids
  • Max solid size 40 mm; abrasive particles accelerate wear
  • Short high-temperature allowance (4 minutes) limits prolonged hot-liquid use
  • Requires RCD (≤30 mA) and proper earthing; needs qualified work for cable replacement
  • Not intended for commercial/industrial use or potable water systems
M: OA-GPT-5-NAN

Product Specification

Power

1200W

Flow rate

5,151.33 gal/h

Delivery height

34.45 ft

Submersion depth

22.97 ft

Pressure

15.23 psi

Hose connection

1 1/2"

Special features

without tank

Cable length

32.81 ft

Weight

22.49 lb

M: OA-GPT-54-NAN

Product Description

T.I.P. Extrema 300/10 IX Electric dirty water submersible pump Manual

The T.I.P. Extrema 300/10 IX is a heavy-duty dirty-water submersible pump designed for reliable domestic drainage and temporary or fixed installations. Built with modern pump technology and robust electrical and mechanical components, this 1,200 W pump handles solids up to 40 mm and delivers up to 19,500 L/h, reaching a maximum head of 10.5 m. It’s intended for non-commercial use: emptying ponds, tanks, wastewater pits and emergency flood drainage. The unit is IPX8 rated for submersion, has a 10 m H07RN-F power cable, and a 1½" male pressure outlet (47.80 mm) for flexible or rigid discharge lines.

Key features and operation

The pump includes an adjustable float switch for automatic on/off control and can be set to manual operation by locking the float—though manual use requires supervision to avoid dry running. A short-term high-temperature capability allows operation up to 95 °C for a maximum of 4 minutes; normal continuous operation is limited to 50 °C. The pump has integrated thermal motor protection that trips under overload and restarts after cooling. Minimum self-priming and suction levels are specified to avoid loss of performance; maximum immersion depth is 7 m.

Installation emphasizes leak-free connections, frost protection, secure positioning on firm ground (not loose stones or sand), and protecting power connections from flooding. For stationary installs rigid piping with a non-return valve and shut-off valve is recommended to avoid backflow and simplify maintenance. Use an RCD (residual current device) with ≤30 mA trip current, and ensure correct earthing and supply voltage per the nameplate.

Maintenance is minimal when used properly: periodic cleaning or counter-flushing through the discharge port can remove deposits; the pump foot can be removed to clear stubborn debris. Avoid sand and abrasive solids where possible to reduce wear. In case of faults, the manual lists troubleshooting steps (no power, blocked impeller, air in pump body, float-switch issues, thermal trips, worn impeller) and advises contacting authorized service for repairs beyond basic clearing and checks. Store the pump frost-free and fully drained when not in use.

Warranty, spare parts and service details: private end-users receive a two-year warranty against material and workmanship defects (subject to terms and exclusions). Spare parts and ordering are available via the manufacturer’s website and customer service; service contact information and instructions for warranty claims are provided.

Notes

  • Intended for domestic use only; not for potable public water networks, swimming pools, aquariums, saltwater, fecal waste or hazardous fluids.
  • Use appropriate hoses/pipes sized at least to the pump outlet to avoid flow loss.
  • Observe the specified maximum start frequency (30 starts/hour) and the thermal protection behavior with hot liquids.
  • Keep the pump and cables away from children and ensure RCD protection.
M: OA-GPT-5-NAN

© Copyright 2026 Manual.ly