Extrema 300/10 IX Maintenance Schedule
Inspect the pump visually before each use, especially the mains cable and plug. Ensure all screws are tight and connections are in perfect condition.
Clean the hydraulic part from sediments by counter-flushing with clear water through the pressure port. Remove tenacious dirt by loosening screws on the pump foot.
Remove the pump from the liquid and drain it completely to prevent damage from freezing. Store in a dry, frost-protected place.
Ask a Question
Do you recommend Extrema 300/10 IX?
Yes NoFrequently Asked Questions
It handles clear and dirty water containing solids up to 40 mm, suitable for pond, tank and pit drainage and emergency flood pumping. It is not suitable for saltwater, fecal waste, flammable, corrosive, explosive or other hazardous liquids.
Is this answer helpful?
Continuous operation is rated up to 50 °C. The pump can operate short-term with liquid temperatures up to 95 °C for a maximum of 4 minutes, after which thermal protection will shut the motor off to cool.
Is this answer helpful?
The built-in float switch automatically starts and stops the pump at adjustable cut-in and cut-out levels by changing the free cable length in the cable guide. It can be locked for manual operation, but manual use requires constant supervision to prevent dry running.
Is this answer helpful?
Use a properly earthed 230 V AC supply with a residual current device (RCD) ≤30 mA. The pump has a 10 m H07RN-F cable; any cable or plug replacement must be performed by qualified personnel and extension cables must match the cable specification.
Is this answer helpful?
Under normal use the pump is largely maintenance-free. Periodically clear the intake and discharge of debris, counter-flush deposits through the discharge port, and remove the pump foot to clean stubborn dirt. Always disconnect power before maintenance and store the pump drained and frost-free.
Is this answer helpful?
Check for clogged intake or discharge lines, trapped air in the pump (start several times to purge), ensure minimum suction level is met and the float switch is set and free-moving, and inspect any check valve for blockage.
Is this answer helpful?
Private end-users have a two-year warranty against material and workmanship defects. It excludes normal wear parts (impeller, seals), damage from misuse, improper repairs, external events, and noncompliant installations. Proof of purchase is required for claims.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- High flow rate up to 19,500 L/h with 1,200 W motor for efficient drainage
- Adjustable float switch for automatic and manual operation (with supervision)
- IPX8 submersible rating and 10 m cable for flexible installations
- Short-term high-temperature handling up to 95 °C (max 4 minutes)
- Integrated thermal motor protection and clear troubleshooting guidance
Disadvantages
- Not suitable for saltwater, fecal matter, flammable or corrosive liquids
- Max solid size 40 mm; abrasive particles accelerate wear
- Short high-temperature allowance (4 minutes) limits prolonged hot-liquid use
- Requires RCD (≤30 mA) and proper earthing; needs qualified work for cable replacement
- Not intended for commercial/industrial use or potable water systems
Product Specification
Power
1200W
Flow rate
5,151.33 gal/h
Delivery height
34.45 ft
Submersion depth
22.97 ft
Pressure
15.23 psi
Hose connection
1 1/2"
Special features
without tank
Cable length
32.81 ft
Weight
22.49 lb
Product Description
T.I.P. Extrema 300/10 IX Electric dirty water submersible pump Manual
The T.I.P. Extrema 300/10 IX is a heavy-duty dirty-water submersible pump designed for reliable domestic drainage and temporary or fixed installations. Built with modern pump technology and robust electrical and mechanical components, this 1,200 W pump handles solids up to 40 mm and delivers up to 19,500 L/h, reaching a maximum head of 10.5 m. It’s intended for non-commercial use: emptying ponds, tanks, wastewater pits and emergency flood drainage. The unit is IPX8 rated for submersion, has a 10 m H07RN-F power cable, and a 1½" male pressure outlet (47.80 mm) for flexible or rigid discharge lines.
Key features and operation
The pump includes an adjustable float switch for automatic on/off control and can be set to manual operation by locking the float—though manual use requires supervision to avoid dry running. A short-term high-temperature capability allows operation up to 95 °C for a maximum of 4 minutes; normal continuous operation is limited to 50 °C. The pump has integrated thermal motor protection that trips under overload and restarts after cooling. Minimum self-priming and suction levels are specified to avoid loss of performance; maximum immersion depth is 7 m.
Installation emphasizes leak-free connections, frost protection, secure positioning on firm ground (not loose stones or sand), and protecting power connections from flooding. For stationary installs rigid piping with a non-return valve and shut-off valve is recommended to avoid backflow and simplify maintenance. Use an RCD (residual current device) with ≤30 mA trip current, and ensure correct earthing and supply voltage per the nameplate.
Maintenance is minimal when used properly: periodic cleaning or counter-flushing through the discharge port can remove deposits; the pump foot can be removed to clear stubborn debris. Avoid sand and abrasive solids where possible to reduce wear. In case of faults, the manual lists troubleshooting steps (no power, blocked impeller, air in pump body, float-switch issues, thermal trips, worn impeller) and advises contacting authorized service for repairs beyond basic clearing and checks. Store the pump frost-free and fully drained when not in use.
Warranty, spare parts and service details: private end-users receive a two-year warranty against material and workmanship defects (subject to terms and exclusions). Spare parts and ordering are available via the manufacturer’s website and customer service; service contact information and instructions for warranty claims are provided.
Notes
- Intended for domestic use only; not for potable public water networks, swimming pools, aquariums, saltwater, fecal waste or hazardous fluids.
- Use appropriate hoses/pipes sized at least to the pump outlet to avoid flow loss.
- Observe the specified maximum start frequency (30 starts/hour) and the thermal protection behavior with hot liquids.
- Keep the pump and cables away from children and ensure RCD protection.
Search for 67,706 Manuals online
Type-in Brand or Model
Peter Schneider
10 months ago
Is the delivery really fast, and does the pump arrive in good condition (packaging, contact), even if I have not used it yet?
Manual.ly
10 months ago
Based on customer feedback, shipping is very fast and the pump arrives well handled. Reviewers reported everything was perfect on delivery and praised the contact/communication. In at least one case, the pump had not been put to use yet because of an ongoing situation, but the delivery and condition were still described as excellent. If you receive your order damaged or incomplete, please contact support right away so we can help with the next steps.