b4505f43ffaaa3be0a00c497728a53047337 page a
Translation of the Original Operating Instructions
1
Dear customer,
Congratulation for buying your new device from T.I.P.!
Like all our products, this one, too, was developed using the latest technological knowledge. The device was
manufactured and assembled on the basis of state-of-the-art pump technology using most reliable electrical or
electronic components which ensure a high level of quality and a long life of your new product.
Please read through these operating instructions carefully to make sure that you can fully benefit from all features.
Some explanatory illustrations can be found at the end of these operating instructions.
We hope you will enjoy your new device!
Table of contents
1. General safety information ............................................................................................................................. 1
2. Technical Data ............................................................................................................................................... 2
3. Range of use .................................................................................................................................................. 2
4. Scope of delivery ........................................................................................................................................... 3
5. Installation ...................................................................................................................................................... 3
6. Electrical connection ...................................................................................................................................... 4
7. Putting into operation ..................................................................................................................................... 4
8. Automation with special accessories ............................................................................................................. 5
9. Maintenance and troubleshooting .................................................................................................................. 5
10. Warranty ........................................................................................................................................................ 6
11. How to order spare parts ................................................................................................................................ 7
12. Service ........................................................................................................................................................... 7
Annex: Illustrations
1. General safety information
Please read through these operating instructions carefully and make yourself conversant with the control
elements and the proper use of this product. We shall not be liable in the case of damage caused as a result of
the non-observance of instructions and provisions of the present operating instructions. Any damage caused as a
result of the non-observance of the instructions and regulations contained in the present operating instructions
shall not be covered by the warranty terms. Please keep these operating instructions in a safe place and hand
them on together with the device should you ever dispose of it.
Persons not conversant with the contents of these operating instructions must not
use this device.
The pump must not be used by children.
The pump may be used by persons with reduced physical, sensory or mental
capabilities or lack of experience and / or knowledge if they have been supervised or
instructed in the safe use of the equipment and have understood the resulting
hazards. Children are not allowed to play with the device. Keep the appliance and its
cord out of reach of children.
The pump must not be used when people are in the water.
The pump must be supplied through a residual current device (RCD) having a rated
residual operating current not exceeding 30mA.
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
Notes and instructions with the following symbols require particular attention:
Any non-observance of these instructions involves the danger of bodily harm to people and/or
damage to property.
Any non-observance of this instruction bears the risk of an electrical shock which may cause
damage to persons or property.
Please inspect the device for damage occurred during transportation. In case of damage, the retailer has to be
informed immediately, at the latest within 8 days after the date of purchase.
8

Chat with your T.I.P. AJ 4 Plus Series manual using AI

Get instant AI answers from your T.I.P. AJ 4 Plus Series manual

Ask anything about the T.I.P. AJ 4 Plus Series. Answers come from this manual, with the pages they are based on.

AJ 4 Plus Series Maintenance Schedule

Before each use
Visual inspection of pump and cable

Check the mains connection line and plug for damage. Ensure all screws are tight and connections are in perfect condition before every use.

As needed
Clean intake filter

If water is not clean, disconnect power and remove pump from water. Clean the outer surface with a steel brush or remove the stainless steel panel to clean inside.

M: QW-35-FL

Ask a Question

0/1000

Do you recommend AJ 4 Plus Series?

Yes No

Frequently Asked Questions

A

It is designed for clean water from deep wells, boreholes, cisterns, and storage tanks. Typical uses include garden irrigation, sprinkler systems, terrace cleaning, and non-potable domestic water supply.

Is this answer helpful?

A

The pump has a nominal power rating of 1,100 W, a maximum flow rate of 6,000 liters per hour, a maximum pressure of 5.7 bar, and a maximum delivery height of 57 meters.

Is this answer helpful?

A

The pump starts after connection to power and restarts when water use drops system pressure below about 3 bar. It shuts down after water demand stops and flow reaches a minimal level.

Is this answer helpful?

A

The maximum submersion depth is 20 meters. Position it vertically and keep it at least 0.5 meters above the well bottom to limit the intake of sediment and debris.

Is this answer helpful?

A

Its dry-run protection makes several pumping attempts, pauses between cycles, and eventually enters error mode if no water is available. Correct the cause, then unplug the pump for about 10 seconds to reset it.

Is this answer helpful?

A

No. It is not intended for drinking water or pool use. It must also not be used with saltwater, sewage, flammable, corrosive, explosive, or other hazardous liquids.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • Delivers up to 6,000 l/h, with a maximum head of 57 m and pressure up to 5.7 bar.
  • Slim 9.8 cm diameter supports installation in narrow boreholes and deep well shafts.
  • Automatic control starts below about 3 bar and stops when demand ends.
  • Integrated dry-run, thermal motor, and non-return valve protection improve operating safety.
  • Includes a 23 m power cable and lowering rope for deep-well installation.
VS

Disadvantages

  • Suitable only for clean water with particles up to 2 mm; sand and abrasive debris increase wear.
  • Not intended for drinking water, swimming pools, saltwater, sewage, or hazardous liquids.
  • Maximum liquid temperature is limited to 35 C.
  • Requires a properly grounded electrical supply with a 30 mA RCD.
  • Dry-run fault mode requires manual reset after the water supply issue is corrected.
M: gpt-5.6-terra

Product Specification

Features

tankless

M: gpt-5.6-terra

Product Description

T.I.P. Electric Deep Well Pump Manual: Powerful Water Supply for Wells and Gardens

The T.I.P. Electric Deep Well Pump AJ 4 Plus 100/57 AUT is a compact submersible pressure pump designed to bring clean water up from deep wells, boreholes, cisterns, and storage tanks. With a slim 9.8 cm diameter body, it is particularly suitable for narrow shafts where larger pumps cannot fit. Its combination of strong pressure, automatic control, and protective features makes it a practical choice for private water supply and irrigation projects.

Powered by a 1,100 W motor, this model can deliver up to 6,000 liters per hour and reach a maximum delivery head of 57 meters. It produces up to 5.7 bar of pressure, supporting demanding tasks such as watering large gardens, operating sprinkler systems, washing terraces, and supplying non-potable household water. The pump is intended for clean, clear water containing particles no larger than 2 mm.

Automatic pressure-controlled operation

A major benefit highlighted in the T.I.P. Electric Deep Well Pump Manual is its integrated electronic control system. Once connected to power, the pump begins after an approximately 10-second delay. It starts automatically when water is drawn and system pressure drops below about 3 bar. When taps or connected consumers are closed, the unit stops after flow falls to a minimum level.

This automatic operation offers the convenience of a household water system without requiring a separate pressure vessel. The delayed shutoff, which can last up to 40 seconds, helps reduce excessive cycling during low-flow use. An integrated non-return valve also prevents water from flowing back into the pump after shutdown and helps protect the system from pressure surges.

Installation and operating protection

The pump can be submerged to a maximum depth of 20 meters and should be positioned at least 0.5 meters above the bottom of the well. This clearance helps reduce the intake of sludge, sand, and stones. A 23-meter power cable and lowering rope are supplied, while the pressure hose or pipe should match at least the 1-inch outlet diameter.

Built-in dry-run protection and thermal motor protection add reassurance during normal operation. If water is unavailable, the pump makes repeated restart attempts before entering an error mode. After the cause is corrected, disconnecting power for around 10 seconds resets the system. The intake filter can be cleaned when needed, but internal repairs should be left to authorized service personnel.

Note: This pump is for private applications and clean, non-drinking water only. Do not use it for swimming pools, saltwater, sewage, flammable liquids, or liquids above 35 C. Use a properly grounded supply protected by a 30 mA RCD.