2.4 Emergency Responses
Manufacturer takes foreseeable risk scenarios into consideration and is designed to
reduce hazards and dangers. However, if the following situation occurs, do as below:
Situation Occurs
Description and action need
Leakage
Avoid touch of leaking liquid or gas. If you touch the leaking
electrolyte, do as below immediately.
Inhalation: Evacuate the contaminated area, and seek medical help.
Eye contact: Rinse eyes with flowing water for 15 minutes, and seek
medical help.
Skin contact: Rinse contacted area thoroughly with soap and water,
and seek medical help.
Ingestion: Vomiting, and seek medical help.
On fire
It's hard for battery system ignite spontaneously. If the battery has
caught a fire, do not try to extinguish the fire but evacuate people
immediately.
Wet Packs
If the battery system is soaked or submerged in water, do not access
it. Contact Growatt or distributors immediately for technical
assistance.
Damaged shell
Damage to the shell is very dangerous, so special attention must be
paid. They are no longer suitable for use and may be dangerous to
personnel. If the battery case is damaged, please stop using it and
contact Growatt or a distributor.
Storage and Transportation 3
3.1 Storage Requirements
Ø Place the product follow the identification on the packing case during storage.
Ø Do not put the product upside down or sidelong.
Ø The defective product needs to be separated from other product.
Ø The storage environment requirements are as follows:
Ÿ Place the product in a dry, clean and well ventilated place.
Ÿ The storage temperature for a short week(7 days) is between -20°C to 50℃.
Ÿ If you store the product over a long period of six months, the storage temperature is
between -20°C to 40°C, relative humidity: 5%~95%RH.
Ÿ Place the product away from corrosive and organic substances (including gas
exposure).
Ÿ Free from direct exposure to sunlight and rain.
Ÿ At least two meters away from heat sources (such as a radiator) .
Ÿ Free from exposure to intensive infrared radiation.
Ø If the battery is stored for more than six months, the battery pack shall be recharged to
40% SOC every six months using a charger.
3.2 Transportation Requirement
Battery pack has been certified in UN38.3 (Section 38.3 of the sixth Revised Edition of the
Recommendations on the Transport of Dangerous Goods: Manual of Tests and Criteria)
and SN/T 0370.2-2009 (Part 2: Performance Test of the Rules for the Inspection of
Packaging for Exporting Dangerous Goods). Battery pack is classified as category 9
dangerous goods.
Ø The battery pack shall not be transported with other inflammable, explosive or toxic
substances.
Ø Ensure the original Package and label complete and recognizable.
Ø Prohibit direct exposure to sunlight, rain, condensing water caused by temperature
difference and mechanical damages.
Ø Prohibit to pile up more than six battery pack.
Ø There will be a drop in capacity during transportation and storage.
Ø Transportation temperature is between -20°C to 40°C, relative humidity: 5%~95%RH.
If not follow the above instructions for long-term storage, the battery
cycle life will be reduced or even damaged.
Notice

Chat with your Growatt ARK HV H manual using AI

Get instant AI answers from your Growatt ARK HV H manual

Ask anything about the Growatt ARK HV H. Answers come from this manual, with the pages they are based on.

ARK HV H Maintenance Schedule

Remind me when maintenance is due
Quarterly
Perform discharge/charge cycle if unused

If the battery is not operated for a longer period, perform a discharge/charge cycle every 3 months to maintain chemical properties. Do not exceed 6 months between charges.

Show in the manual (page 12)
Every 6 Months
Charge battery to 40% SOC during long-term storage

If the battery is stored for longer than six months, charge it to 40% State of Charge using a charger every six months.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend ARK HV H?

Yes No

Frequently Asked Questions

A

You can connect up to ten ARK 2.5H-A1 battery modules in series to expand the system capacity. This configuration allows you to achieve higher voltage and total energy storage tailored to your specific needs.

Is this answer helpful?

A

Yes, the system has an IP65 rating, making it suitable for outdoor use. However, it must be protected from direct sunlight and rain using appropriate shading or shelter to ensure longevity and safety.

Is this answer helpful?

A

The battery operates between -10°C and +50°C. Performance may be limited when ambient temperatures drop below 0°C, but the system includes thermal management to protect cells and ensure safe operation.

Is this answer helpful?

A

The system is optimized for use with Growatt PCS inverters using the CAN communication protocol. While physical connections might be possible, full functionality and safety features are best realized with compatible Growatt equipment.

Is this answer helpful?

A

If communication between the battery and PCS fails, the system will trigger an alarm. It may stop discharging to prevent unsafe conditions. You should check cable connections and contact a qualified technician if the issue persists.

Is this answer helpful?

A

If storing the battery for more than six months, you must recharge it every six months to a 40% State of Charge (SOC). This prevents deep discharge damage and maintains cell health during long-term inactivity.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Modular design allows scaling from 2 to 10 units for flexible capacity
  • High safety standards with LFP chemistry and comprehensive BMS protection
  • IP65 rated enclosure supports versatile indoor and outdoor installation
  • Excellent round-trip efficiency minimizes energy waste during cycles
  • Real-time monitoring via CAN protocol ensures stable system operation
VS

Disadvantages

  • Requires professional installation due to high voltage and safety risks
  • Initial setup cost may be higher compared to lower voltage alternatives
  • System performance can degrade slightly in extreme cold temperatures below zero
  • Strict compatibility requirements limit use with non-Growatt inverters
  • Heavy modules require reinforced mounting structures for wall installation
M: QW-35-FL

Product Specification

Note

Prices include partial 0% VAT rates for AT and DE

Battery Type

LiFePO4

Operating Temperature

14°F to 122°F

Lifespan

10 years

Display

No

Features

Battery Management System, State of Charge Indicator, Soft Start, Emergency Power Function

Interfaces

RS-485

Mounting Type

Freestanding (stackable), Wall-mounted

Protection Class

IP65

M: QW-35-FL

Product Description

Unlocking Energy Independence with the Growatt ARK HV H

The Growatt ARK HV H represents a significant leap in residential and commercial energy storage, designed to maximize solar self-consumption and ensure power reliability during outages. This high-voltage battery system integrates seamlessly with Growatt inverters to create a robust energy ecosystem. By utilizing advanced Lithium Iron Phosphate (LFP) technology, the system offers superior safety, extended cycle life, and consistent performance across varying environmental conditions.

At the heart of the ARK HV H is a modular architecture that allows for scalable deployment. Users can configure the system by connecting between two and ten battery modules in series, tailoring the total capacity to meet specific energy demands. Whether powering a single home or a small business facility, the system intelligently manages energy flow. During daylight hours, excess solar generation is stored efficiently, while at night or during grid failures, the battery discharges to keep essential loads running without interruption.

Installation flexibility is a key feature, supporting both wall-mounted and floor-standing configurations. The unit boasts an IP65 rating, making it suitable for indoor and outdoor environments provided it is shielded from direct weather exposure. Advanced monitoring capabilities via CAN communication allow real-time tracking of voltage, current, and temperature, ensuring optimal operation and immediate alerts for any anomalies. Safety is paramount, with built-in protections against overvoltage, overheating, and short circuits, all managed by a sophisticated Battery Management System (BMS).

Key Operational Highlights

The system operates within a wide temperature range, maintaining efficiency even in challenging climates. Its high round-trip efficiency ensures minimal energy loss during charge and discharge cycles. Regular maintenance is straightforward, with clear indicators guiding users through diagnostics and module replacement if necessary. The integration of smart software updates ensures the system evolves with new features and security patches.

Important Notes

  • Always ensure professional installation to maintain warranty validity.
  • Regularly check ventilation areas to prevent overheating.
  • Use only compatible Growatt components for optimal performance.
  • Store spare modules in a dry, climate-controlled environment.
M: QW-35-FL