T90/T110/T130/T150
Voltage/Continuity Tester
Instruction Sheet
Introduction
The Fluke T90/T110/T130/T150 Electrical Testers (the
Tester or Product) are voltage and continuity testers
with a rotary eld indication (T110/T130/T150 only).
Their primary use is for test and measurement in
industrial, commercial, and household environments.
This Product complies with the most recent safety
standards for safe, reliable test and measurement.
The xed test probe cover prevents the risk of injury
when you move the instrument.
How to Contact Fluke
To contact Fluke, call one of the following telephone
numbers:
• Germany: 07684 - 80 09 545
• France: 01 48 17 37 37
• United Kingdom: +44-0-1603256600
Go to www.uke.com to register your product,
download manuals, and nd more information.
To view, print, or download the latest manual
supplement, visit http://us.uke.com/usen/support/
manuals.
Safety Information
 Warning
To prevent possible electrical shock, re, or
personal injury:
● Read all safety Information before you use the
Product.
● Use the Product only as specied, or the
protection supplied by the Product can be
compromised.
● Measure a known voltage rst to make sure
that the Product operates correctly.
● Do not apply more than the rated voltage,
between the terminals or between each
terminal and earth ground.
PN 3928132
October 2011, Rev. 1, 10/13
© 2011, 2013 Fluke Corporation. All rights reserved.
Specications are subject to change without notice. All product
names are trademarks of their respective companies.
● Limit operation to the specied measurement
category or voltage ratings.
● Do not work alone.
● Comply with local and national safety codes.
Use personal protective equipment (approved
rubber gloves, face protection, and ame-
resistant clothes) to prevent shock and arc
blast injury where hazardous live conductors
are exposed.
● Do not use the Product around explosive gas,
vapor, or in damp or wet environments.
● Do not use and disable the Product if it is
damaged.
● Do not use the Product if it operates
incorrectly.
● Keep ngers behind the nger guards on the
probes.
● Do not use the Product if the test leads are
damaged.
● Examine the case before you use the Product.
Look for cracks or missing plastic.
● The battery door must be closed and fastened
before you operate the Product.
● Replace the batteries when the low battery
indicator shows to prevent incorrect
measurements.
● Repair the Product before use if the battery
leaks.
● For use by competent persons. Anyone
using this Product should be knowledgeable
and trained about the risks involved with
measuring voltage, especially in an industrial
setting, and the importance of taking safety
precautions and of testing the Product before
and after using it to ensure that it is in good
working condition.
Symbols
These symbols are on the Tester or in this instruction
sheet.
Symbol Explanation
Important information. Consult the
instruction sheet.
Hazardous Voltage.
Suitable for live working.
Symbol Explanation
This product complies with the WEEE
Directive (2002/96/EC) marking
requirements. The afxed label indicates
that you must not discard this electrical/
electronic product in domestic household
waste. Product Category: With reference
to the equipment types in the WEEE
Directive Annex I, this product is classed
as category 9 "Monitoring and Control
Instrumentation" product. Do not dispose
of this producat as unsorted municipal
wast. To to Fluke's website for recycling
information.
Conforms to European Union Directives
CAT III Measurement Category III is applicable to
test and measuring circuits connected to
the distribution part of the building’s low-
voltage MAINS installation.
CAT IV Measurement Category IV is applicable
to test and measuring circuits connected
at the source of the building’s low-voltage
MAINS installation.
Accessories
The Tester is supplied with accessories.
Part Number Accessory
4083642 GS38 Probe Tip Sheath
4083656 4 mm ∅ Probe Extensions
4111533 H15 Belt Holster (sold separately)
4111540
C150 Zippered Soft Carrying Case
(sold separately)
Figure 1 shows the Probe Tip Protector Cap. This
multifunctional accessory is useful for tests and
storage of different accessories.
Storage area for Probe Tip Sheaths
Storage area for 4 mm ∅ Probe Extensions
Earth-pin safety-socket opener for UK
sockets (press opener into socket to release
safety covers, see Figure 2)
Storage area for probes when not in use
2
1
4
3
1
2
Quick Reference
Use the pushbuttons to turn the functions on or off.
See the list that follows for a quick reference to each
of these pushbuttons.
Pushbutton Description
c
Push to turn torch light on or off
(T110, T130, T150).
To save battery power the
function automatically turns off
after 30 seconds.
I
Push to hold the value that shows
in the LCD in volt and resistance
measurements. Push again to
turn HOLD off (T130, T150).
To save battery power the
function automatically turns off
after 30 seconds.
h
Push this button on each of
the probes at the same time to
start the test for low impedance
switchable load.
cp
Push and hold for 2 seconds to
turn the beeper on or off. The
status shows on the LCD (T150,
T130) or with the LED (T110).
Il
Push and hold for 2 seconds to
turn the resistance measurement
on or off (T150 only).
To save battery power, the
function automatically turns off
after 30 seconds.
Figure 3 illustrates how to store and retrieve the tip
accessories from the cap.
For storage, push Probe Tip Sheath into
place.
To retrieve, rmly push probe tip into Probe
Tip Sheath.
Pull on probe handle to remove Probe Tip
Sheath.
For storage, push 4 mm ∅ Probe Extensions
into place.
To retrieve, rmly push probe tip into Probe
Extensions. Twist 1/4 turn.
Pull on probe handle to remove Probe
Extensions. Continue to twist until tip is tight.
3
1
4
2
5
1/4
3
6

Chat with your Fluke T150 manual using AI

Get instant AI answers from your Fluke T150 manual

Ask anything about the Fluke T150. Answers come from this manual, with the pages they are based on.

T150 Maintenance Schedule

Remind me when maintenance is due
Yearly
Calibrate the tester

Fluke recommends a calibration interval of 1 year.

Before and after each use
Perform the tester self-test

Touch probe tips together, verify battery and indicators, then measure a known voltage. Do not use the tester if it fails.

Before each use
Inspect the tester case

Examine the case for cracks or missing plastic. Do not use the product if it is damaged.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: gpt-5.6-terra

Ask a Question

0/1000

Do you recommend T150?

Yes No
0
User Pic

Laura Schmidt

10 months ago

Can I switch off the annoying beep or acoustic signal on the Fluke T150/VDE when verifying mains voltage, or is it always on?

0
User Pic

Manual.ly

10 months ago

On the Fluke T150/VDE, the acoustic signal is intended as a safety alert and, in this version, it cannot be fully disabled. Users therefore hear the tone during voltage verification and during certain test functions. To reduce distraction, rely on the visual indications on the display/LEDs and the measurement light instead of the sound. If your unit ever behaves unusually, contact support with the device details so it can be checked or replaced under warranty.

M: OA-GPT-5-NAN
M: OA-GPT-5-NAN

Video Manual

Fluke Spannungs- und Durchgangsprüfer T150/VDE Vorstellung + Funktionserläuterung

Frequently Asked Questions

A

The T150 detects voltages from low levels upward: LEDs operate from 12 V to 690 V AC/DC; the LCD displays from 6 V to 690 V with 1 V resolution on models with an LCD.

Is this answer helpful?

A

Yes. By pressing both load buttons simultaneously you activate a low-impedance mode that can trip typical 10 mA or 30 mA RCDs in a 230 V system. The load is overload-protected and will reduce current after ~20 seconds at 230 V (or ~2 seconds at 690 V).

Is this answer helpful?

A

The single-pole phase test identifies phase presence by holding the indicator probe body and touching the tip to a conductor; it signals above ~100 V AC. It’s meant for quick checks but not to validate zero voltage—use the voltage measurement mode for precise verification.

Is this answer helpful?

A

The T150 offers CAT III/CAT IV overvoltage ratings, double insulation, fixed probe cover, finger guards, an independent ELV LED (>50 V AC or >120 V DC), IP64 protection, and built-in self-tests to confirm correct operation before use.

Is this answer helpful?

A

Yes. The T150 measures resistance from 0 to 1999 Ω with 1 Ω resolution; typical tolerance is ±(5 % reading + 10 digits) at 20 °C. The resistance function must be enabled and the unit should be used only on de-energized circuits.

Is this answer helpful?

A

Remove batteries when storing long-term, replace batteries when the low-battery indicator appears, align polarity when installing, and perform a self-test after replacement. Promptly address any battery leakage and have repairs performed by approved technicians.

Is this answer helpful?

A

The beeper is switchable on models with the feature. Press and hold the beeper button for two seconds to toggle it on or off. Always test continuity with probes touched together to confirm the beeper functions before use.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • High safety ratings (CAT III 690 V / CAT IV 600 V) and IP64 protection for rugged, on-site use.
  • Switchable low-impedance load allows RCD trip testing and reduces interference from stray coupling.
  • Compact slim probes, probe-tip storage cap, and accessory sheaths for tight spaces and organized transport.
  • Multi-function: voltage, continuity, diode, resistance (1–1999 Ω), single-pole phase, and rotary field indication.
  • Built-in self-test, independent ELV LED, and beeper/hold/torch features improve reliability and usability.
VS

Disadvantages

  • LCD numeric measurement is available only on advanced variants (T130/T150), limiting exact readings on base models.
  • Switchable load is time-limited by overload protection—current reduces after ~20s at 230 V and ~2s at 690 V.
  • Resistance measurement range is limited to 0–1999 Ω, unsuitable for high-resistance insulation testing.
  • Beeper and some functions may be less effective in high ambient noise; always verify audibly before tests.
  • Requires AAA batteries; battery leakage can damage the unit if left unused without removal.
M: OA-GPT-5-NAN

Product Specification

Measurement Range

6-690V

M: OA-GPT-54-NAN

Product Description

Fluke T150 VDE Voltage Tester — Reliable, Compact, and Safe

The Fluke T150 VDE Voltage Tester is a compact, rugged voltage and continuity tester designed for electricians and technicians working in industrial, commercial, and residential environments. Combining a clear LED bargraph with an LCD readout (on advanced models) and a range of safety-focused features, the T150 delivers fast visual indication of voltages from low-voltage circuits up to high mains levels. Its slim probe tips, fixed probe cover, and integrated probe-tip protector cap make it convenient for tight spaces and safe storage.

Built to meet strict safety standards, the T150 features CAT III/CAT IV overvoltage protection ratings, IP64 ingress protection, and double-insulated wiring. The unit offers automatic power-on detection above low-voltage thresholds, a visual >ELV indicator that flags voltages above 50 V AC or 120 V DC, and an internal low-impedance mode with a switchable load for RCD trip tests. These options let users reduce interference from capacitive or inductive coupling and verify RCD operation by applying realistic trip currents during measurements.

Beyond basic voltage testing, the T150 provides continuity and diode testing, a low-ohm resistance function (1–1999 Ω) with 1 Ω resolution, and a rotary field indicator for three-phase phase-sequence checks. A useful single-pole phase test and an independent ELV indicator LED ensure rapid detection of live conductors even if batteries fail. Additional conveniences include a torch/backlight for dim workspaces, a beeper (switchable) for continuity and phase indications, and a HOLD function for capturing readings on the LCD.

Ergonomically designed, the tester supports single-handed operation and can be used while wearing gloves. Built-in self-test and clear battery-low indicators help ensure dependable operation before and after use. Accessories such as probe tip sheaths, 4 mm probe extensions, and a holster/carry case improve versatility on the job.

This tester is ideal for electricians who need a portable, safety-certified instrument that handles common tasks—voltage detection, continuity checks, RCD trip testing, and phase sequencing—while providing robust protection and user-friendly features.

Notes

  • The >ELV LED warns at >50 V AC or >120 V DC and should not replace true measurement validation. Use the LCD for numeric readings when needed.
  • Switchable load (two-button press) is time-limited by overload protection; expect current reduction after ~20 seconds at 230 V.
  • Always perform the self-test and verify the beeper/continuity before starting live work.