7. Testingofmagneticfields(g. D)
- Apply the test probe
1
to the activated magnet of the test object.
- The detection of a magnetic field is indicated by the test probe
1
lighting up green.
- If an acoustic signal is emitted during the test and the test probe
1
simultaneously lights up red
and green, an electric field of a live part is also detected.
Note:
Pressing the push-button
4
has no inuence on the sensitivity of the magnetic eld test.
8. Batteryreplacement(gure A)
- Do not apply voltage to the device when the battery compartment is open!
- Remove the battery compartment cover
6
from the indicator and remove the used batteries.
- Insert new micro batteries (LR03/AAA) into the indicator observing correct polarity (positive pole
first).
- Screw the battery compartment cover
6
back onto the indicator.
9. Technicaldata
- regulation: DIN EN 61010-1, DIN EN 61326
- nominal voltage/frequency range: 12 V/200 V to 1,000 V AC/45 Hz to 65 Hz
- overvoltage category: CAT III 1,000 V/CAT IV 600 V
- contamination level: 2
- protection category: IP 53 (DIN EN 60529), protection against dust and water spray
- operating temperature range: - 0 °C to + 50 °C, air humidity ≤ 80 %
- storage temperature range: - 20 °C to + 60 °C, air humidity ≤ 80% (without batteries)
- dimensions of the indicator (L x W x H): approx. 153 x 20 x 25 mm
- weight: approx. 40 g (incl. batteries)
- battery type: 2 x micro, LR03/AAA (1.5 V)
The BENNING VT 2 phase indicator and magnetic eld tester does not work with the battery being
exhausted!
10. General maintenance
Clean the exterior of the device with a clean dry cloth.
If there is contamination or deposits in the area of the battery or the battery housing, clean these areas
as well by means of a dry cloth. If the device is stored for a longer period of time, remove the batteries
from the device!
11. Environmental protection
At the end of product life, dispose of the unserviceable device as well as used batteries via
appropriate collecting facilities provided in your community.

Chat with your Benning VT 2 manual using AI

Get instant AI answers from your Benning VT 2 manual

Ask anything about the Benning VT 2. Answers come from this manual, with the pages they are based on.

VT 2 Maintenance Schedule

Before and after each use
Check device functionality

Verify the phase indicator and magnetic field tester work correctly immediately before and after every use. Do not use if functions fail.

Show in the manual (page 12)
When weak signal occurs
Replace batteries

Replace the two LR03/AAA batteries as soon as the red LED indication or acoustic signal becomes weaker.

Show in the manual (page 12)
As needed
Clean housing and battery compartment

Clean the exterior of the device with a clean dry cloth. Also clean the battery area if contamination or deposits are present.

Show in the manual (page 14)
Before long-term storage
Remove batteries for storage

If the device is stored for a longer period of time, remove the batteries from the device to prevent damage.

Show in the manual (page 14)
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend VT 2?

Yes No
0
User Pic

Yvonne Mason

5 months ago

Is this product small enough to be portable and does it fully meet its intended purpose?

0
User Pic

Manual.ly

5 months ago

Yes, the product is designed to be compact and practical for easy portability. Based on user feedback, it fully satisfies its primary function and meets customer expectations effectively.

M: QW-35-FL
M: QW-35-FL

Frequently Asked Questions

A

No, the BENNING VT 2 is designed to detect alternating current (AC) fields only. It cannot detect direct current (DC) voltage fields.

Is this answer helpful?

A

Users with pacemakers or implanted defibrillators should keep a sufficient distance from the device because its internal magnets can affect the functioning of these medical implants.

Is this answer helpful?

A

You should test the device immediately before and after use. Check the phase function on a known voltage source like a 230 V socket and test the magnetic field function using the integrated test magnet.

Is this answer helpful?

A

The device requires two Micro batteries, specifically type LR03 or AAA (1.5 V), inserted with the correct polarity.

Is this answer helpful?

A

No. The BENNING VT 2 is not a substitute for a two-pole voltage tester. You must use a certified two-pole tester to definitively confirm the absence of voltage.

Is this answer helpful?

A

If the probe tip lights up red and green at the same time, it indicates that both an electrical field from a live part and a magnetic field are being detected simultaneously.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Detects AC voltages from 12 V to 1000 V without physical contact
  • Identifies both electrical and magnetic fields with clear LED and audio feedback
  • Includes a built-in test magnet for immediate functional verification
  • High sensitivity mode allows detection of low voltages around 12 V AC
  • Durable design with IP53 protection against dust and water spray
VS

Disadvantages

  • Incapable of detecting DC voltage fields
  • Not suitable for confirming zero voltage status compared to two-pole testers
  • Magnets inside may interfere with implanted medical devices like pacemakers
  • Requires regular battery replacement to maintain optimal performance
  • Effectiveness can be reduced by thick insulation or heavy shielding on conductors
M: QW-35-FL

Product Specification

Measurement range

12-1000V

M: QW-35-FL

Product Description

Benning VT 2 Non-contact Phase Tester – Read, Download & Print Free

The BENNING VT 2 is a versatile non-contact phase indicator and magnetic field tester designed for professional electricians. This device allows users to detect electrical fields generated by AC voltages ranging from approximately 12 volts up to 1000 volts without the need for direct physical contact with live parts. It also features the capability to identify strong magnetic fields produced by electromagnetic switches, relays, and solenoid valves.

Designed with safety as a priority, the BENNING VT 2 operates within specific overvoltage categories (CAT III 1000 V and CAT IV 600 V) and includes a built-in test magnet for verifying functionality before use. The device utilizes a clear LED system where a red light indicates the presence of an electrical field, while a green light signals a detected magnetic field. An acoustic signal accompanies these visual cues, increasing in frequency as the voltage or field strength rises. A special high-sensitivity mode can be activated by holding a blue button, enabling the detection of lower voltages starting around 12 volts AC.

This tool is essential for locating phases in external conductors, identifying interruptions in live cables such as broken wires in cable reels, and checking for magnetic fields in industrial equipment. It does not require current flow during testing, making it a safe option for preliminary checks. However, it is crucial to remember that this device is not a substitute for a two-pole voltage tester when determining the absolute absence of voltage. Users must always follow strict safety protocols, including keeping a safe distance from pacemakers due to the internal magnets, and ensuring the battery compartment is closed during operation.

Important Notes

  • Always perform a functional check before and after every use.
  • Do not touch the white probe tip during testing; hold only the red handle behind the grip limit.
  • Remove batteries if the device will be stored for extended periods to prevent leakage.
  • Ensure the device is used only by qualified personnel in accordance with safe working procedures.
M: QW-35-FL