9.4 Fuse replacement (BENNING MM 6-2)
Before opening the BENNING MM 6-2, ensure that it is not
connected to a source of voltage! Electrical hazard!
The BENNING MM 6-2 is protected against overload by means of an inte grated
fuse (G melt insert) 11 A rapid (see figure 14). Proceed as follows to replace
the fuse:
- Disconnect the safety measuring leads from the measurement circuit.
- Disconnect the safety measuring leads from the BENNING MM 6-2.
- Turn the rotating switch
to the “OFF” position.
- Remove the protective rubber holster
M
from the BENNING MM 6-2.
- Put the BENNING MM 6-2 face down and unscrew the four outer screws
(black) from the bottom part of the housing.
Do not loosen any of the screws on the printed circuit of the
BENNING MM 6-2!
- Lift the housing base at the bottom and remove it from the top of the front part.
- Lift one end of the defective fuse out of the fuse holder.
- Push the defective fuse out of the fuse holder completely.
- Replace the defective fuse with another of the same rated power, same trig-
gering characteristics and same dimensions.
- Push the new fuse into the centre of the holder.
- Clip the housing base into the front part and replace the four screws.
- Clip the battery cover onto the bottom part and tighten the screw.
- Replace the BENNING MM 6-2 in its protective rubber holster
M
.
See fig. 14: Fuse replacement
9.5 Calibration
Benning guarantees compliance with the technical and accuracy specifications
stated in the operating manual for the first 12 months after the delivery date.
To maintain the specified accuracy of the measurement results, the instrument
must be recalibrated at regular intervals by our factory service. We recommend
a recalibration interval of one year. Send the appliance to the following address:
Benning Elektrotechnik & Elektronik GmbH & CO. KG
Service Centre
Robert-Bosch-Str. 20
D - 46397 Bocholt
9.6 Spare parts
Fuse F 11 A, 1000 V, 30 kA, D = 10 mm, L = 38 mm, P.no. 10218772
10. How to use the protective rubber holster
- The safety measuring leads can be stored by coiling them round the protec-
tive rubber holster
M
and clipping the probe into the holster
M
so that they
are sufficiently protected (see fig. 15)
- You can clip one lead onto the protective rubber holster
M
in such a way that
the measuring probe projects. This allows you to bring the measuring probe
and the BENNING MM 6-1/ MM 6-2 up to the measuring point together.
- The support at the back of the holster
M
can be used to prop the
BENNING MM 6-1/ MM 6-2 up in a diagonal position (to make reading
easier) (see fig. 16).
- The protective rubber holster
M
is provided with a magnet which can be
used for suspension.
See fig. 15: Winding up the safety measuring leads
See fig. 16: Standing up the BENNING MM 6-1/ MM 6-2
11. Technical data of the measuring accessories
- Standard: EN 61010-031,
- Maximum rated voltage to earth () and measuring category:
With push-on caps: 1000 V CAT III, 600 V CAT IV,
Without push-on caps: 1000 V CAT II,
- Maximum rated current: 10 A,
- Protective class II (
), continuous double or reinforced insulation,
- Contamination class: 2,
- Length: 1.4 m, AWG 18,
- Environmental conditions:
Maximum barometric elevation for making measurements: 2000 m,
Temperatures: 0 °C to + 50 °C, humidity 50 % to 80 %
- Only use the measuring leads if in perfect and clean condition as well as
according to this manual, since the protection provided could otherwise be
impaired.

Chat with your Benning MM 6-2 manual using AI

Get instant AI answers from your Benning MM 6-2 manual

Ask anything about the Benning MM 6-2. Answers come from this manual, with the pages they are based on.

MM 6-2 Maintenance Schedule

Remind me when maintenance is due
Yearly
Calibrate the multimeter

Send the device to Benning Service Center for recalibration to maintain specified accuracy. Recommended interval is one year.

Show in the manual (page 30)
Regularly
Clean the housing

Wipe the outside of the unit with a clean dry cloth or special cleaning cloth. Do not use solvents or abrasives.

Show in the manual (page 29)
As needed
Replace the 9V battery

Replace the battery when all segments in the battery symbol disappear and the symbol flashes.

Show in the manual (page 29)
Before each use
Inspect device and leads

Check the instrument and measuring leads for signs of damage before starting operation. Secure against accidental use if damaged.

Show in the manual (page 21)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend MM 6-2?

Yes No
0
User Pic

Margarita Simonis

4 months ago

Does this multimeter automatically detect whether I am measuring AC or DC voltage?

0
User Pic

Manual.ly

4 months ago

Yes, the Benning MM 6-2 features an AutoV function that automatically identifies whether the measured value is direct current (DC) or alternating current (AC). This ensures accurate readings without manual switching. The device also includes a 20-minute auto-off feature to preserve battery life and comes with a protective holster containing a magnet for hands-free operation.

M: QW-35-FL
M: QW-35-FL
0
User Pic

Jace Lowe

6 months ago

Is the battery included in the box or do I need to buy it separately?

M: QW-35-FL

Frequently Asked Questions

A

The device is rated for CAT IV 600 V between conductor and ground, and CAT III 1000 V for line-to-line measurements. It must not be used in circuits exceeding these limits.

Is this answer helpful?

A

Yes, but only if equipped with the optional Type K wire temperature sensor. The standard unit measures voltage, current, resistance, frequency, and capacitance directly.

Is this answer helpful?

A

A battery symbol appears on the display. When all segments disappear and the symbol begins to blink, the battery must be replaced immediately to prevent measurement errors.

Is this answer helpful?

A

No, the device is designed for dry surroundings only. It has an IP30 rating, which offers no protection against water ingress.

Is this answer helpful?

A

The blue function key selects secondary functions for the rotary switch positions, such as switching between AC/DC current types or enabling frequency measurement modes.

Is this answer helpful?

A

Benning recommends calibrating the device annually by sending it to their service center to maintain the specified accuracy specifications guaranteed for the first year.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • True RMS measurement for accurate readings on non-sinusoidal signals
  • CAT IV 600V and CAT III 1000V safety rating for high-risk environments
  • VoltSense non-contact voltage detection with audio and visual alerts
  • Auto-range selection simplifies operation for quick diagnostics
  • Durable rubber holster with integrated magnet for hands-free use
VS

Disadvantages

  • Temperature measurement requires a separate K-type sensor accessory
  • No backlight illumination for low-light conditions
  • Battery replacement requires removing the protective rubber holster
  • Manual range switching can be less intuitive than fully automatic models
  • Maximum voltage against earth is limited to 600V in CAT IV settings
M: QW-35-FL

Product Specification

Measurement Range

max. 10A, max. 1000V, max. 40MΩ

Package Contents

Bag

M: QW-35-FL

Product Description

Benning MM 6-2 Multimeter: Precision and Safety for Professionals

The Benning MM 6-2 Multimeter stands as a robust tool designed for electricians and technically trained individuals who demand high accuracy in their measurements. This digital device excels in dry environments, offering a comprehensive suite of functions including direct current voltage, alternating current voltage, resistance, diode testing, continuity checks, capacitance measurement, frequency analysis, and temperature monitoring via the optional K-type sensor. Its True RMS capability ensures reliable readings even with non-sinusoidal waveforms, making it indispensable for complex electrical diagnostics.

Safety is paramount in the design of the Benning MM 6-2. Rated for CAT IV 600 V and CAT III 1000 V, it provides a secure environment for working on high-energy circuits when used with appropriate safety leads and protective caps. The unit features VoltSense technology for non-contact voltage detection, alerting users to live phases through an audible buzzer and red LED indicator without needing physical contact. The smart display includes a bargraph for visualizing trends and auto-power-off functionality to conserve the long-lasting 9-volt battery life, which can reach up to 200 hours on alkaline power.

Ergonomics are also considered, with a durable rubber protective frame that shields the device from mechanical damage. This frame doubles as a stand for easier reading and includes a magnet for hands-free operation. The included compact carrying case and safety leads ensure the multimeter is always ready for immediate deployment on any job site. Whether checking continuity with a buzzer or measuring microamps, the Benning MM 6-2 delivers the precision required for professional-grade electrical work.

M: QW-35-FL

© Copyright 2026 Manual.ly