BENNING MM 6-1/ 6-2
21
2. Safety notes
The instrument is built and tested in accordance with
DIN VDE 0411 part 1/EN 61010-1
DIN VDE 0411 part 2-033/EN 61010-2-033
DIN VDE 0411 part 031/EN 61010-031
and has left the factory in perfectly safe technical condition.
To maintain this condition and to ensure safe operation of the multimeter, the
user must observe the notes and warnings given in these instructions at all times.
Improper handling and non-observance of the warnings might involve severe
injuries or danger to life.
WARNING! Be extremely careful when working with bare con-
ductors or main line carrier! Contact with live conductors will
cause an electric shock!
Attention! Magnets might affect the correct functioning of
cardiac pacemakers and implanted defibrillators. As a user of
such medical devices, keep a sufficient distance to the magnet.
The BENNING MM 6-1/ MM 6-2 may be used only in electrical
circuits of over voltage category III with a maximum voltage of
1000 V or of over voltage category IV with a maximum voltage
of 600 V between the conductor and ground.
Only use suitable measuring leads for this. With measurements
within measurement category III or measurement category IV,
the projecting conductive part of a contact tip of the measuring
leads must not be longer than 4 mm.
Prior to carrying out measurements within measurement cat-
egory III and measurement category IV, the push-on caps
provided with the set and marked with CAT III and CAT IV must
be pushed onto the contact tips. The purpose of this measure
is user protection.
Remember that work on electrical components of all kinds is
dangerous. Even low-voltages of 30 V AC and 60 V DC may be
dangerous to human life.
Before starting the multimeter, always check it as well as all
measuring leads and wires for signs of damage.
Should it appear that safe operation of the multimeter is no longer possible, it
should be shut down immediately and secured to prevent that it is switched on
accidentally.
It may be assumed that safe operation is no longer possible:
- if the instrument or the measuring leads show visible signs of damage, or
- if the multimeter no longer works, or
- after long periods of storage under unfavourable conditions, or
- after being subject to rough transportation, or
- if the device or the measuring leads are exposed to moisture.
In order to avoid danger,
- do not touch the bare probe tips of the measuring leads,
- insert the measurement leads in the appropriately
designated measuring sockets on the multimeter
Cleaning:
Regularly wipe the housing by means of a dry cloth and
cleaning agent. Do not use any polishing agents or solvents!
3. Scope of delivery
The following items make up the standard BENNING MM 6-1/ MM 6-2 package:
3.1 one BENNING MM 6-1/ MM 6-2,
3.2 one safety measuring lead, red (L = 1.4 m),
3.3 one safety measuring lead, black (L = 1.4 m),
3.4 one wire temperature sensor, type K (only BENNING MM 6-1)
3.5 one protective rubber holster with magnetic holder,
3.6 one compact protection carrying case,
3.7 one 9 V block battery is integrated into the device,
3.8 one fuse for initial assembly is integrated into the device
(BENNING MM 6-2),
3.9
one operating manual.

Chat with your Benning MM 6-2 manual using AI

Get instant AI answers from your Benning MM 6-2 manual

Ask anything about the Benning MM 6-2. Answers come from this manual, with the pages they are based on.

MM 6-2 Maintenance Schedule

Remind me when maintenance is due
Yearly
Calibrate the multimeter

Send the device to Benning Service Center for recalibration to maintain specified accuracy. Recommended interval is one year.

Show in the manual (page 30)
Regularly
Clean the housing

Wipe the outside of the unit with a clean dry cloth or special cleaning cloth. Do not use solvents or abrasives.

Show in the manual (page 29)
As needed
Replace the 9V battery

Replace the battery when all segments in the battery symbol disappear and the symbol flashes.

Show in the manual (page 29)
Before each use
Inspect device and leads

Check the instrument and measuring leads for signs of damage before starting operation. Secure against accidental use if damaged.

Show in the manual (page 21)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend MM 6-2?

Yes No
0
User Pic

Margarita Simonis

4 months ago

Does this multimeter automatically detect whether I am measuring AC or DC voltage?

0
User Pic

Manual.ly

4 months ago

Yes, the Benning MM 6-2 features an AutoV function that automatically identifies whether the measured value is direct current (DC) or alternating current (AC). This ensures accurate readings without manual switching. The device also includes a 20-minute auto-off feature to preserve battery life and comes with a protective holster containing a magnet for hands-free operation.

M: QW-35-FL
M: QW-35-FL
0
User Pic

Jace Lowe

6 months ago

Is the battery included in the box or do I need to buy it separately?

M: QW-35-FL

Frequently Asked Questions

A

The device is rated for CAT IV 600 V between conductor and ground, and CAT III 1000 V for line-to-line measurements. It must not be used in circuits exceeding these limits.

Is this answer helpful?

A

Yes, but only if equipped with the optional Type K wire temperature sensor. The standard unit measures voltage, current, resistance, frequency, and capacitance directly.

Is this answer helpful?

A

A battery symbol appears on the display. When all segments disappear and the symbol begins to blink, the battery must be replaced immediately to prevent measurement errors.

Is this answer helpful?

A

No, the device is designed for dry surroundings only. It has an IP30 rating, which offers no protection against water ingress.

Is this answer helpful?

A

The blue function key selects secondary functions for the rotary switch positions, such as switching between AC/DC current types or enabling frequency measurement modes.

Is this answer helpful?

A

Benning recommends calibrating the device annually by sending it to their service center to maintain the specified accuracy specifications guaranteed for the first year.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • True RMS measurement for accurate readings on non-sinusoidal signals
  • CAT IV 600V and CAT III 1000V safety rating for high-risk environments
  • VoltSense non-contact voltage detection with audio and visual alerts
  • Auto-range selection simplifies operation for quick diagnostics
  • Durable rubber holster with integrated magnet for hands-free use
VS

Disadvantages

  • Temperature measurement requires a separate K-type sensor accessory
  • No backlight illumination for low-light conditions
  • Battery replacement requires removing the protective rubber holster
  • Manual range switching can be less intuitive than fully automatic models
  • Maximum voltage against earth is limited to 600V in CAT IV settings
M: QW-35-FL

Product Specification

Measurement Range

max. 10A, max. 1000V, max. 40MΩ

Package Contents

Bag

M: QW-35-FL

Product Description

Benning MM 6-2 Multimeter: Precision and Safety for Professionals

The Benning MM 6-2 Multimeter stands as a robust tool designed for electricians and technically trained individuals who demand high accuracy in their measurements. This digital device excels in dry environments, offering a comprehensive suite of functions including direct current voltage, alternating current voltage, resistance, diode testing, continuity checks, capacitance measurement, frequency analysis, and temperature monitoring via the optional K-type sensor. Its True RMS capability ensures reliable readings even with non-sinusoidal waveforms, making it indispensable for complex electrical diagnostics.

Safety is paramount in the design of the Benning MM 6-2. Rated for CAT IV 600 V and CAT III 1000 V, it provides a secure environment for working on high-energy circuits when used with appropriate safety leads and protective caps. The unit features VoltSense technology for non-contact voltage detection, alerting users to live phases through an audible buzzer and red LED indicator without needing physical contact. The smart display includes a bargraph for visualizing trends and auto-power-off functionality to conserve the long-lasting 9-volt battery life, which can reach up to 200 hours on alkaline power.

Ergonomics are also considered, with a durable rubber protective frame that shields the device from mechanical damage. This frame doubles as a stand for easier reading and includes a magnet for hands-free operation. The included compact carrying case and safety leads ensure the multimeter is always ready for immediate deployment on any job site. Whether checking continuity with a buzzer or measuring microamps, the Benning MM 6-2 delivers the precision required for professional-grade electrical work.

M: QW-35-FL

© Copyright 2026 Manual.ly