Manual.ly Logo

Benning MM 6-2 Manual

5.0 · 1 Ratings

PDF manual · 144 Pages

English

M: QW-35-FL
page

/ 144

Loading...
1073337a83fe56817a21cbe9219ad899d4d3 page 1d
02/ 2020
BENNING MM 6-1/ 6-2
29
tivity).
- Connect the red safety measuring lead to the jack
J
for V of the
BENNING MM 6-1/ MM 6-2.
- Bring the safety measuring lead into contact with the measuring point of the
system part.
- If an acoustic signal is emitted and the red LED
N
lights, the phase of an
earthed alternating voltage is applied to this measuring point (system part).
9. Maintenance
Before opening the BENNING MM 6-1/ MM 6-2, ensure that it is
not connected to a source of voltage! Electrical hazard!
Any work required on the BENNING MM 6-1/ MM 6-2 when it is under voltage must
be done only by a qualified electrician. Special steps must be taken to prevent
accidents. Before opening the BENNING MM 6-1/ MM 6-2, remove it from all sources
of voltage as follows:
- First remove both safety measuring leads from the measurement points.
- Remove both safety measuring leads from the BENNING MM 6-1/ MM 6-2
- Turn the rotating switch
to “OFF”.
9.1 Securing the unit
Under certain circumstances, the safety of the BENNING MM 6-1/ MM 6-2 can
no longer be guaranteed. This may be the case if:
- there are visible signs of damage on the unit,
- errors occur in measurements,
-
the unit has been stored for a long period of time under the wrong conditions, and
- if the unit has been subjected to rough handling during transport.
In these cases, the BENNING MM 6-1/ MM 6-2 must be switched off immediately,
removed from the measuring points and secured to prevent it from being used again.
9.2 Cleaning
Clean the outside of the unit with a clean dry cloth. (Exception: any type of
special cleaning cloth). Never use solvents or abrasives to clean the testing unit.
Ensure that the battery compartment and the battery contacts have not been
contaminated by electrolyte leakage.
If any electrolyte or white deposits are seen near to the battery or in the battery
compartment, remove them with a dry cloth, too.
9.3 Battery replacement
Before opening the BENNING MM 6-1/ MM 6-2, ensure that it is
not connected to a source of voltage! Electrical hazard!
The BENNING MM 6-1/ MM 6-2 is supplied by means of one 9 V block battery.
Battery replacement (see figure 13) is required as soon as all segments of the
battery symbol
3
have disappeared and the battery symbol is flashing.
To replace the battery, proceed as follows:
- First remove the safety measuring leads from the measurement circuit.
- Remove the safety measuring leads from the BENNING MM 6-1/ MM 6-2.
- Turn the rotating switch
to “OFF”.
- Remove the protective rubber holster
M
from the BENNING MM 6-1/ MM 6-2.
- Lay the BENNING MM 6-1/ MM 6-2 on its front and loosen the screw from
the cover of the battery compartment.
- Lift off the battery compartment cover from the bottom part of the battery
compartment.
- Lift the discharged battery out of the battery compartment and remove the
battery leads carefully from the battery.
- Connect the new battery with the battery leads and arrange them in such a
way that they are not crushed between the two halves of the housing. Then
place the battery in the correct position in the battery compartment.
- Clip the battery cover onto the bottom part and tighten the screws.
- Replace the BENNING MM 6-1/ MM 6-2 in its protective rubber holster
M
.
See fig. 13: Battery replacement
Remember the environment! Do not dispose of used batteries
with domestic waste. Dispose of them at a battery-collection
point or as toxic waste. Your local authority will give you the
information you need.

Chat with your Benning MM 6-2 manual using AI

Get instant AI answers from your Benning MM 6-2 manual

Ask anything about the Benning MM 6-2. Answers come from this manual, with the pages they are based on.

MM 6-2 Maintenance Schedule

Remind me when maintenance is due
Yearly
Calibrate the multimeter

Send the device to Benning Service Center for recalibration to maintain specified accuracy. Recommended interval is one year.

Show in the manual (page 30)
Regularly
Clean the housing

Wipe the outside of the unit with a clean dry cloth or special cleaning cloth. Do not use solvents or abrasives.

Show in the manual (page 29)
As needed
Replace the 9V battery

Replace the battery when all segments in the battery symbol disappear and the symbol flashes.

Show in the manual (page 29)
Before each use
Inspect device and leads

Check the instrument and measuring leads for signs of damage before starting operation. Secure against accidental use if damaged.

Show in the manual (page 21)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend MM 6-2?

Yes No
0
User Pic

Margarita Simonis

4 months ago

Does this multimeter automatically detect whether I am measuring AC or DC voltage?

0
User Pic

Manual.ly

4 months ago

Yes, the Benning MM 6-2 features an AutoV function that automatically identifies whether the measured value is direct current (DC) or alternating current (AC). This ensures accurate readings without manual switching. The device also includes a 20-minute auto-off feature to preserve battery life and comes with a protective holster containing a magnet for hands-free operation.

M: QW-35-FL
M: QW-35-FL
0
User Pic

Jace Lowe

6 months ago

Is the battery included in the box or do I need to buy it separately?

M: QW-35-FL

Frequently Asked Questions

A

The device is rated for CAT IV 600 V between conductor and ground, and CAT III 1000 V for line-to-line measurements. It must not be used in circuits exceeding these limits.

Is this answer helpful?

A

Yes, but only if equipped with the optional Type K wire temperature sensor. The standard unit measures voltage, current, resistance, frequency, and capacitance directly.

Is this answer helpful?

A

A battery symbol appears on the display. When all segments disappear and the symbol begins to blink, the battery must be replaced immediately to prevent measurement errors.

Is this answer helpful?

A

No, the device is designed for dry surroundings only. It has an IP30 rating, which offers no protection against water ingress.

Is this answer helpful?

A

The blue function key selects secondary functions for the rotary switch positions, such as switching between AC/DC current types or enabling frequency measurement modes.

Is this answer helpful?

A

Benning recommends calibrating the device annually by sending it to their service center to maintain the specified accuracy specifications guaranteed for the first year.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • True RMS measurement for accurate readings on non-sinusoidal signals
  • CAT IV 600V and CAT III 1000V safety rating for high-risk environments
  • VoltSense non-contact voltage detection with audio and visual alerts
  • Auto-range selection simplifies operation for quick diagnostics
  • Durable rubber holster with integrated magnet for hands-free use
VS

Disadvantages

  • Temperature measurement requires a separate K-type sensor accessory
  • No backlight illumination for low-light conditions
  • Battery replacement requires removing the protective rubber holster
  • Manual range switching can be less intuitive than fully automatic models
  • Maximum voltage against earth is limited to 600V in CAT IV settings
M: QW-35-FL

Product Specification

Measurement Range

max. 10A, max. 1000V, max. 40MΩ

Package Contents

Bag

M: QW-35-FL

Product Description

Benning MM 6-2 Multimeter: Precision and Safety for Professionals

The Benning MM 6-2 Multimeter stands as a robust tool designed for electricians and technically trained individuals who demand high accuracy in their measurements. This digital device excels in dry environments, offering a comprehensive suite of functions including direct current voltage, alternating current voltage, resistance, diode testing, continuity checks, capacitance measurement, frequency analysis, and temperature monitoring via the optional K-type sensor. Its True RMS capability ensures reliable readings even with non-sinusoidal waveforms, making it indispensable for complex electrical diagnostics.

Safety is paramount in the design of the Benning MM 6-2. Rated for CAT IV 600 V and CAT III 1000 V, it provides a secure environment for working on high-energy circuits when used with appropriate safety leads and protective caps. The unit features VoltSense technology for non-contact voltage detection, alerting users to live phases through an audible buzzer and red LED indicator without needing physical contact. The smart display includes a bargraph for visualizing trends and auto-power-off functionality to conserve the long-lasting 9-volt battery life, which can reach up to 200 hours on alkaline power.

Ergonomics are also considered, with a durable rubber protective frame that shields the device from mechanical damage. This frame doubles as a stand for easier reading and includes a magnet for hands-free operation. The included compact carrying case and safety leads ensure the multimeter is always ready for immediate deployment on any job site. Whether checking continuity with a buzzer or measuring microamps, the Benning MM 6-2 delivers the precision required for professional-grade electrical work.

M: QW-35-FL

© Copyright 2026 Manual.ly