In these cases, the BENNING MM 5-1/ MM 5-2 must be switched off immediately,
removed from the measuring points and secured to prevent it from being used again.
9.2 Cleaning
Clean the outside of the unit with a clean dry cloth. (Exception: any type of
special cleaning cloth). Never use solvents or abrasives to clean the testing unit.
Ensure that the battery compartment and the battery contacts have not been
contaminated by electrolyte leakage.
If any electrolyte or white deposits are seen near to the battery or in the battery
compartment, remove them with a dry cloth, too.
9.3 Battery replacement
Before opening the BENNING MM 5-1/ MM 5-2, ensure that it is
not connected to a source of voltage! Electrical hazard!
The BENNING MM 5-1/ MM 5-2 is supplied by means of two integrated 1.5 V
micro (AAA) batteries. Battery replacement (see figure 13) is required as soon
as all segments of the battery symbol
3
have disappeared and the battery
symbol is flashing.
To replace the battery, proceed as follows:
- First remove the safety measuring leads from the measurement circuit.
- Remove the safety measuring leads from the BENNING MM 5-1/ MM 5-2.
- Turn the rotating switch
to “OFF”.
- Remove the protective rubber holster
M
from the BENNING MM 5-1/ MM 5-2.
- Lay the BENNING MM 5-1/ MM 5-2 on its front and loosen the screw from
the cover of the battery compartment.
- Lift off the battery compartment cover from the bottom part of the battery
compartment.
- Remove the discharged batteries from the battery compartment.
- Insert the new batteries into the battery compartment observing correct
po larity.
- Clip the battery cover onto the bottom part and tighten the screw.
- Replace the BENNING MM 5-1/ MM 5-2 in its protective rubber holster
M
.
See fig. 13: Battery replacement
Remember the environment! Do not dispose of used batteries
with domestic waste. Dispose of them at a battery-collection
point or as toxic waste. Your local authority will give you the
information you need.
9.4 Fuse replacement (BENNING MM 5-2)
Before opening the BENNING MM 5-2, ensure that it is not
connected to a source of voltage! Electrical hazard!
The BENNING MM 5-2 is protected against overload by means of an inte grated
fuse (G melt insert) 15 A rapid (see figure 14). Proceed as follows to replace
the fuse:
- Disconnect the safety measuring leads from the measurement circuit.
- Disconnect the safety measuring leads from the BENNING MM 5-2.
- Turn the rotating switch
to the “OFF” position.
- Remove the protective rubber holster
M
from the BENNING MM 5-2.
- Lay the BENNING MM 5-2 on its front and loosen the screw from the cover
of the battery compartment.
- Lift off the battery compartment cover from the bottom part of the battery
compartment.
Do not loosen any of the screws on the printed circuit of the
BENNING MM 5-2!
- Remove the four outer screws (black) from the bottom part of the housing.
- Lift the housing base at the bottom and remove it from the top of the front part.
- Lift one end of the defective fuse out of the fuse holder.
- Push the defective fuse out of the fuse holder completely.
- Replace the defective fuse with another of the same rated power, same trig-
gering characteristics and same dimensions.
- Push the new fuse into the centre of the holder.
- Clip the housing base into the front part and replace the four screws.
- Clip the battery cover onto the bottom part and tighten the screw.
- Replace the BENNING MM 5-2 in its protective rubber holster
M
.
See fig. 14: Fuse replacement

Chat with your Benning MM 5-1 manual using AI

Get instant AI answers from your Benning MM 5-1 manual

Ask anything about the Benning MM 5-1. Answers come from this manual, with the pages they are based on.

MM 5-1 Maintenance Schedule

Remind me when maintenance is due
Yearly
Calibrate the device at factory service

Send the instrument to Benning Service Center for recalibration to maintain specified accuracy. Recommended interval is one year.

Show in the manual (page 30)
Regularly
Clean the housing exterior

Wipe the outside of the unit with a clean dry cloth. Do not use solvents or abrasives.

Show in the manual (page 29)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend MM 5-1?

Yes No

Frequently Asked Questions

A

The Benning MM 5-1 can safely measure voltages up to 600 V DC or AC in Category III circuits and up to 300 V in Category IV circuits relative to ground.

Is this answer helpful?

A

No, the Benning MM 5-1 model does not have built-in temperature measurement capabilities. This feature is available on the Benning MM 5-2 model which supports a K-type thermocouple.

Is this answer helpful?

A

Turn the device off, remove the rubber holster, unscrew the back cover, take out the old batteries, insert new 1.5 V micro batteries with correct polarity, and reassemble the unit.

Is this answer helpful?

A

The VoltSensor function allows you to detect the presence of AC voltage against earth without making physical contact, indicated by a red LED and a symbol on the display.

Is this answer helpful?

A

No, the device is designed strictly for dry environments. Using it in wet conditions or high humidity can compromise safety and accuracy.

Is this answer helpful?

A

Benning recommends recalibrating the device every year to maintain the specified measurement accuracy and compliance with technical specifications.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • True RMS measurement technology for accurate readings on non-sinusoidal signals
  • VoltSensor function allows non-contact AC voltage detection
  • Durable design with protective rubber holster and magnetic holder
  • Smart HOLD and Peak value storage for capturing transient data
  • Complies with CAT III 600V and CAT IV 300V safety standards
VS

Disadvantages

  • Battery life may decrease significantly in cold temperatures
  • No built-in temperature measurement (requires separate sensor)
  • Cannot measure frequency on current inputs without specific setup
  • Requires manual fuse replacement for overload protection
  • Limited to dry environments only, no water resistance
M: QW-35-FL

Product Specification

Measurement Range

max. 600V, max. 100MΩ

Package Contents

Bag

M: QW-35-FL

Product Description

The Benning MM 5-1 Multimeter: Precision and Safety in Every Measurement

The Benning MM 5-1 Multimeter stands as a reliable tool for electricians and technically trained individuals who require accurate diagnostics in dry environments. Designed with safety as a priority, this device supports measurements up to 600 V DC/AC, adhering to strict overvoltage categories III and IV standards. Its robust construction includes a protective rubber holster that not only shields the unit from mechanical damage but also features an integrated magnet for hands-free operation and a stand for easier reading.

This digital multimeter offers a comprehensive suite of functions including direct voltage, alternating voltage, resistance, diode testing, and continuity checks with an audible buzzer. The large 4-digit LCD display ensures clear visibility of readings, while features like Smart HOLD and Peak value storage allow users to capture transient data effortlessly. The inclusion of a VoltSensor function enables non-contact detection of AC voltages against earth, adding a layer of convenience and safety during phase identification tasks. With a measurement rate of two per second and automatic range selection, the Benning MM 5-1 streamlines complex electrical troubleshooting into a seamless process.

Powering the device are two standard 1.5 V micro batteries, providing approximately 300 hours of continuous use. The unit is equipped with a battery indicator that alerts users when replacement is needed, preventing inaccurate readings due to low power. Whether checking circuits, testing components, or diagnosing faults, the Benning MM 5-1 delivers consistent performance backed by a one-year calibration guarantee from the manufacturer.

Key Features Summary

The Benning MM 5-1 combines durability with advanced functionality. Its True RMS technology ensures accurate readings even on non-sinusoidal waveforms within specified limits. The device complies with EU directives and features double insulation for enhanced user protection. Maintenance is straightforward, with easy access for battery and fuse replacement, ensuring long-term reliability in professional settings.

Important Notes

Always ensure the device is de-energized before opening it for maintenance. Magnets inside the unit can affect pacemakers, so keep a safe distance if you have such medical implants. Do not use the device in wet conditions or beyond its rated voltage limits.

M: QW-35-FL

© Copyright 2026 Manual.ly