BENNING MM 5-1/ 5-2
20
Operating Manual
BENNING MM 5-1/ MM 5-2
Digital Multimeter for
- DC voltage measurement
- AC voltage measurement
- DC current measurement (BENNING MM 5-2)
- AC current measurement (BENNING MM 5-2)
- Resistance measurement
- Diode testing
- Continuity testing
- Capacity measurement
- Frequency measurement
- Temperature measurement (BENNING MM 5-2)
Contents:
1. Operating instructions
2. Safety notes
3. Scope of delivery
4. Description of unit
5. General data
6. Ambient conditions
7. Electrical data
8. Measuring with the BENNING MM 5-1/ MM 5-2
9. Maintenance
10. How to use the protective rubber holster
11. Technical data of the measuring accessories
12. Environmental note
1. Operating Instructions
This operating manual is intended for:
- electricians and
- qualified electrotechnical persons
The BENNING MM 5-1/ MM 5-2 is designed for measurements in dry surround-
ings. It must not be used in electrical circuits with rated voltages higher than
600 V DC/ AC (for more details, see section 6 “Ambient conditions”).
The following symbols are used in the operating manual and on the
BENNING MM 5-1/ MM 5-2 itself:
Attention! Magnets might affect the correct functioning of cardiac
pacemakers and implanted defibrillators. As a user of such medical
devices, keep a sufficient distance to the magnet.
Warning of electrical danger!
Indicates instructions which must be followed to avoid danger to
persons.
Important, comply with the documentation!
The symbol indicates that the information provided in the operating
instructions must be followed with in order to avoid risks.
This symbol on the BENNING MM 5-1/ MM 5-2 indicates that the
unit is protection insulated (safety class II).
This symbol on the BENNING MM 5-2 indicates the fuses which
it contains.
This symbol on the BENNING MM 5-1/ MM 5-2 means that the
BENNING MM 5-1/ MM 5-2 complies with the EU directives.
This symbol appears on the display for a discharged battery.
This symbol indicates the “continuity-testing” application. The
buzzer provides an audible signal.
This symbol indicates the “diode-testing” application.
This symbol marks the range “capacity testing”.
(DC) voltage or current.
(AC) voltage or current.
Earth (voltage to earth).

Chat with your Benning MM 5-1 manual using AI

Get instant AI answers from your Benning MM 5-1 manual

Ask anything about the Benning MM 5-1. Answers come from this manual, with the pages they are based on.

MM 5-1 Maintenance Schedule

Remind me when maintenance is due
Yearly
Calibrate the device at factory service

Send the instrument to Benning Service Center for recalibration to maintain specified accuracy. Recommended interval is one year.

Show in the manual (page 30)
Regularly
Clean the housing exterior

Wipe the outside of the unit with a clean dry cloth. Do not use solvents or abrasives.

Show in the manual (page 29)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend MM 5-1?

Yes No

Frequently Asked Questions

A

The Benning MM 5-1 can safely measure voltages up to 600 V DC or AC in Category III circuits and up to 300 V in Category IV circuits relative to ground.

Is this answer helpful?

A

No, the Benning MM 5-1 model does not have built-in temperature measurement capabilities. This feature is available on the Benning MM 5-2 model which supports a K-type thermocouple.

Is this answer helpful?

A

Turn the device off, remove the rubber holster, unscrew the back cover, take out the old batteries, insert new 1.5 V micro batteries with correct polarity, and reassemble the unit.

Is this answer helpful?

A

The VoltSensor function allows you to detect the presence of AC voltage against earth without making physical contact, indicated by a red LED and a symbol on the display.

Is this answer helpful?

A

No, the device is designed strictly for dry environments. Using it in wet conditions or high humidity can compromise safety and accuracy.

Is this answer helpful?

A

Benning recommends recalibrating the device every year to maintain the specified measurement accuracy and compliance with technical specifications.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • True RMS measurement technology for accurate readings on non-sinusoidal signals
  • VoltSensor function allows non-contact AC voltage detection
  • Durable design with protective rubber holster and magnetic holder
  • Smart HOLD and Peak value storage for capturing transient data
  • Complies with CAT III 600V and CAT IV 300V safety standards
VS

Disadvantages

  • Battery life may decrease significantly in cold temperatures
  • No built-in temperature measurement (requires separate sensor)
  • Cannot measure frequency on current inputs without specific setup
  • Requires manual fuse replacement for overload protection
  • Limited to dry environments only, no water resistance
M: QW-35-FL

Product Specification

Measurement Range

max. 600V, max. 100MΩ

Package Contents

Bag

M: QW-35-FL

Product Description

The Benning MM 5-1 Multimeter: Precision and Safety in Every Measurement

The Benning MM 5-1 Multimeter stands as a reliable tool for electricians and technically trained individuals who require accurate diagnostics in dry environments. Designed with safety as a priority, this device supports measurements up to 600 V DC/AC, adhering to strict overvoltage categories III and IV standards. Its robust construction includes a protective rubber holster that not only shields the unit from mechanical damage but also features an integrated magnet for hands-free operation and a stand for easier reading.

This digital multimeter offers a comprehensive suite of functions including direct voltage, alternating voltage, resistance, diode testing, and continuity checks with an audible buzzer. The large 4-digit LCD display ensures clear visibility of readings, while features like Smart HOLD and Peak value storage allow users to capture transient data effortlessly. The inclusion of a VoltSensor function enables non-contact detection of AC voltages against earth, adding a layer of convenience and safety during phase identification tasks. With a measurement rate of two per second and automatic range selection, the Benning MM 5-1 streamlines complex electrical troubleshooting into a seamless process.

Powering the device are two standard 1.5 V micro batteries, providing approximately 300 hours of continuous use. The unit is equipped with a battery indicator that alerts users when replacement is needed, preventing inaccurate readings due to low power. Whether checking circuits, testing components, or diagnosing faults, the Benning MM 5-1 delivers consistent performance backed by a one-year calibration guarantee from the manufacturer.

Key Features Summary

The Benning MM 5-1 combines durability with advanced functionality. Its True RMS technology ensures accurate readings even on non-sinusoidal waveforms within specified limits. The device complies with EU directives and features double insulation for enhanced user protection. Maintenance is straightforward, with easy access for battery and fuse replacement, ensuring long-term reliability in professional settings.

Important Notes

Always ensure the device is de-energized before opening it for maintenance. Magnets inside the unit can affect pacemakers, so keep a safe distance if you have such medical implants. Do not use the device in wet conditions or beyond its rated voltage limits.

M: QW-35-FL

© Copyright 2026 Manual.ly