Manual.ly Logo

Weller WDD 81V Manual

0.0 · 0 Ratings

PDF manual · 107 Pages

English

M: QW-35-FL
page

/ 107

Loading...
0f85006d15fa7e7a621c4d75f24dd84eb17c page 19
18
Standard setback
If the soldering tool is not used within a period of 20 minu-
tes the temperature will be automatically reduced to a
standby temperature of 150°C (300°F). After three setback
periods (60 min.) the ”AUTO OFF” function will be activated
and the soldering iron will be switched off.
Activating the standard setback function: When switching on
the unit press the ”UP” button (3) until ”ON” appears in the
display. The setting is saved when the "UP" button is relea-
sed. Use the same process to switch the unit off. ”OFF” will
appear in the display (state upon delivery).
The use of very fine soldering tips may have a negative
effect on reliable setback function.
Vacuum delay
After the finger switch is released the vacuum remains acti-
ve for approx. 2 seconds.
Setting: When switching on, hold the ”DOWN” key (4) until
ON or OFF appears in the display. The setting is saved when
the "DOWN" button is released. Repeat this step to change.
Maintenance
To obtain good soldering results it is important to regularly
clean the desoldering head. This includes emptying the tin
collection container, replacing the glass tube filter, as well as
checking the seals. Correct sealing of the front face of the
glass cylinder ensures full suction performance. Dirty filters
affect the flow of air through the soldering tool. The main fil-
ter (6) (hose-mounted filter in the vacuum hose) should the-
refore be checked regularly and replaced if necessary. Use a
new original WELLER filter cartridge for this purpose. To
clean the bore in the suction nozzle and the suction tube, use
the cleaning tool (5 13 500 99).
The suction nozzles can be replaced quickly and easily with
a short turning movement (approx. 45°).
English
3. Commissioning
Place the soldering tool in the holder. Insert compressed air
hose with 6 mm outer diameter in the quick action coupling
for the compressed air connection (12). Provide supply of
compressed air with 400-600 kPa (57-87 psi) dry, oil-free
compressed air. Plug the electrical lead from the soldering
tool in the 7 pole socket (9) on the front panel and lock.
Position the main filter (6) with the hose joint between the
vacuum connection (8) and the vacuum connection on the
desoldering tool. Check that the mains voltage matches that
on the rating plate and that the mains switch (1) is in the off
position. Plug the control unit into the mains (10). Switch on
the unit at the mains switch (1). When the unit is switched
on, a self-test is performed during which all the indicators (2)
are illuminated.
The temperature set (required value) and the temperature
scale (ºC / ºF) are then briefly displayed. The electronics then
switch automatically to the display of the actual value. The
red dot (5) on the display (2) illuminates. This dot serves as
an optical regulation monitor. Continuous illumination means
that the system is heating up. Flashing indicates that the
operating temperature has been reached. The vacuum
necessary for desoldering is activated by the integrated fin-
ger switch on the soldering iron.
Setting the Temperature
Ordinarily the digital display (2) indicates the actual tempe-
rature. When the “UP” or “DOWN” button (3) (4) is operated
the digital display (2) switches to the display of the required
value currently set. The required value set (flashing display)
can be changed in the corresponding direction by repeated-
ly pressing or holding down the “UP” or “DOWN” button (3)
(4). The required value can be changed more quickly by hol-
ding the button down. Approx. 2 sec. after releasing the but-
ton the digital display (2) switches automatically back to the
actual value. It is not possible to make changes to the set-
ting on a locked soldering station (LOCK).
Technical Data
Dimensions (mm): 180 (L) x 115 (W) x 101 (H)
(in) 7,1 (L) x 4.53 (W) x 4 (H)
Mains Voltage (10): 230 V / 50 Hz, 120 V / 60 Hz (see rating plate)
Power Consumption: 95 W
Protection Class: 1 (Control Unit) and 3 (Soldering Tool)
Fuse (11): T 500 mA (230 V); T 1 A (120 V) (see rating plate)
Temperature Regulation: Digital 50ºC - 450ºC (150ºF - 850ºF)
Precision: ± 9ºC (± 17ºF)
Compressed Air: Inlet pressure 400-600 kPa (58-87 psi), oil-free, dry compressed air
Compressed Air Converter: Air consumption 35 l / min; max. vacuum 55 kPa (8 psi)
Compressed Air Connection: Compressed air hose of 6 mm (0.24") external diameter
Equipotential Bonding (7): via 3.5 mm jack bushing on the bottom of the unit. (State upon delivery: hard grounded,
plug is not inserted)

Chat with your Weller WDD 81V manual using AI

Get instant AI answers from your Weller WDD 81V manual

Ask anything about the Weller WDD 81V. Answers come from this manual, with the pages they are based on.

WDD 81V Maintenance Schedule

Regularly
Clean the desoldering head and empty tin container

Empty the tin collection container, replace the glass tube filter, and check seals to ensure full suction performance.

Show in the manual (page 25)
Regularly
Inspect and replace the main vacuum filter

Check the hose-mounted main filter regularly for dirt that affects airflow. Replace with a new original WELLER filter cartridge if necessary.

Show in the manual (page 25)
As needed
Clean suction nozzle bore and tube

Use the cleaning tool (5 13 500 99) to clean the bore in the suction nozzle and the suction tube to maintain optimal suction.

Show in the manual (page 25)
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend WDD 81V?

Yes No

Frequently Asked Questions

A

The station supports a digital temperature range from 50°C to 450°C (150°F to 850°F), allowing for both delicate and high-heat applications.

Is this answer helpful?

A

The auto-off function activates automatically after three consecutive setback periods (60 minutes total). You can enable or disable the standard setback function by holding the UP button during startup.

Is this answer helpful?

A

Yes, but only if you purchase the optional WCB 2 external input unit, which includes an RS-232 PC interface for data logging and remote control.

Is this answer helpful?

A

The unit requires dry, oil-free compressed air with an inlet pressure between 400 and 600 kPa (58 to 87 psi).

Is this answer helpful?

A

You should regularly check the main filter and replace it whenever it appears dirty or clogged to ensure maximum suction performance and protect the air converter.

Is this answer helpful?

A

The 3.5mm socket allows you to ground the soldering tip in four different ways (hard grounded, soft grounded, floating, or zero impedance) to prevent electrostatic discharge damage.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Microprocessor-controlled digital temperature regulation ensures high accuracy and stability.
  • Wide range of compatible tools including specialized desoldering irons and tweezers.
  • Optional external input units provide advanced features like locking and PC interfaces.
  • Automatic standby mode saves energy and protects tips during long pauses.
  • Maintenance-free internal air converter generates reliable vacuum pressure.
VS

Disadvantages

  • Requires dry, oil-free compressed air supply which may need additional filtration.
  • Vacuum delay setting must be manually configured for optimal user experience.
  • Some advanced functions require purchasing separate external input units.
  • Filter replacement requires specific original parts for best performance.
  • Initial setup involves multiple safety checks and potential bonding configurations.
M: QW-35-FL

Product Specification

Power

95W

Temperature

122-1022°F

Package Contents

DSX 80 soldering iron, WDH 30 soldering iron stand, maintenance tool, DX 112 suction nozzle, DX 113 suction nozzle

M: QW-35-FL

Product Description

Weller WDD 81V Desoldering Station Set Manual: Your Ultimate Guide to Precision

The Weller WDD 81V Desoldering Station Set Manual is an essential resource for electronics professionals and hobbyists who demand precision in their soldering work. This comprehensive guide covers the operation, maintenance, and safety protocols for the Weller WDD 81V, a microprocessor-controlled desoldering station designed for industrial production, repair shops, and laboratories.

At the heart of this system is advanced digital control electronics that ensure precise temperature regulation at the soldering tip. The station features a high-quality sensor and heat exchange system within the soldering tool, guaranteeing optimal dynamic thermal behavior even under heavy load. Users can set temperatures ranging from 50°C to 450°C using simple Up and Down buttons, with real-time feedback provided by a digital display and an optical regulation monitor LED.

The manual details the various compatible tools included or available as accessories, such as the DSX 80 and DXV 80 desoldering irons, the WTA 50 tweezers for surface-mount components, and the versatile WP 80 soldering iron. Each tool is engineered for specific tasks, offering conical attachment systems for suction nozzles and integrated finger switches for vacuum activation. The system also supports optional external input units like the WCB 1 and WCB 2, which unlock advanced functions such as offset calibration, setback timers, lock modes, and PC connectivity via RS-232.

Proper maintenance is critical for longevity and performance. The manual emphasizes regular cleaning of the desoldering head, emptying tin collection containers, and replacing glass tube filters to maintain optimal airflow. It also explains how to configure equipotential bonding options to prevent static damage to sensitive components. Whether you are performing delicate SMD work or heavy-duty through-hole repairs, understanding the setup and troubleshooting steps outlined in this manual ensures reliable results and extends the life of your equipment.

M: QW-35-FL

© Copyright 2026 Manual.ly