Loading...
e150e37db53ef651200c1138b7cf35b312de page 4
• This device has left our factory premises in a safe and perfect condition.
• We kindly request the user to observe the safety instructions and warnings contained in the
enclosed operating instructions so this condition is maintained and to ensure safe operation.
• The unauthorised conversion and/or modication of the unit is not permitted for safety and
approval reasons (CE).
• Consult a professional if you are unsure how to operate the equipment or how to connect it
safely.
• Meters and their accessories are not toys and should be kept out of the reach of children!
• In commercial institutions, the accident prevention regulations of the Employer’s Liability
Insurance Association for Electrical Systems and Operating Facilities are to be observed.
• In schools, training centres, hobby and self-help workshops, use of the measuring device
must be supervised by trained personnel in a responsible manner.
• Before measuring voltages, always make sure that the measuring instrument is not set to a
measuring range for currents.
• The voltage between any socket of the measuring instrument and earth may not exceed 300
V (DC/AC) in Measurement Category III.
• Be especially cautious when dealing with voltages exceeding >33 V (AC) or >70 V (DC)! Even
at these voltages, there is a danger of fatal electric shock if you touch electric conductors.
• To eliminate the risks of electric shock, do not directly or indirectly touch the connections/
measuring points during measurements. During measuring, do not grip beyond the tactile grip
range markings on the test probes.
• Do not use the multimeter just before, during or just after an electrical storm (electrical shock!
/ high-power surges!). Make sure that your hands, shoes, clothing, the oor, the measuring
device and/or measuring lines, circuits and circuit components are always dry.
• Do not use the tester in rooms or under adverse ambient conditions in which ammable
gases, vapours or explosive dust may be or are present.
• Avoid operation near strong magnetic or electromagnetic elds, transmitter aerials or HF
generators. These can distort the measurement.
• For safety reasons, use only measuring cables or accessories which are adjusted to the
specications of the multimeter when measuring. Only use double, or strengthened, insulated
measuring accessories.
• If you have reason to assume that safe operation is no longer possible, disconnect the device
immediately and secure it against inadvertent operation. Safe operation can no longer be
assumed if:
- the device is visibly damaged,
- the device does not function any more and
- the device was stored under unfavourable conditions for a long period of time or
- it has been subjected to considerable stress during transportation.
• Do not switch the measuring instrument on immediately after it has been taken from a cold
to a warm environment. The condensation that forms might destroy your device. Allow the
device to reach room temperature before switching it on.
• Do not leave packaging material carelessly lying around, as it could become a dangerous
plaything for children.
• Also pay attention to the safety instructions in each chapter of these instructions.
DESIGNATION OF INDIVIDUAL PARTS
1 Analogue scale display
2 Calibration screw for scale pointer
3 0-Ohm calibration control for measuring resistance values
4 Rotary switch for setting the measuring functions and ranges
5 COM socket (reference measuring point, negative pole)
6 V/mA/Ω socket (positive pole)
7 Battery and safety compartment on the reverse side
PRODUCT DESCRIPTION
• The analogue multimeter (hereinafter referred to as multimeter) is equipped with a shock-attenuating
pointer instrument.
• The multimeter can be used in any operating position.
• The mA-current range is protected against overload with a micro fuse.
• The individual measuring functions and ranges are selected with a rotary switch.
• The multimeter can be used for up to CAT III max. 300 V for hobby or professional applications.
• On delivery, the measuring leads may be covered by protective sleeves. Before use, pull the sleeves off
the safety plugs.
• After use, put them back for transport protection.
• The scale pointer can be calibrated with the calibration screw. Perform this before each measurement to
prevent inaccurate measurements.
G
OPERATING INSTRUCTIONS
VC-13A ANALOG MULTIMETER
ITEM NO. 1386327
INTENDED USE
• M
easuring and displaying electrical values in the range of measurement category CAT III up to max. 300 V
against earth potential, pursuant to EN 61010-1
• Alternating and direct voltage measurements up to max. 300 V
• Measurement of direct current up to 250 mA
• Attenuation measurements from -20 dBm to +22 dBm
• Measurement of resistance up to 2 MOhm
• Battery test for 1.5 V and 9 V batteries
The multimeter may be operated only with a Mignon battery (AA, UM3, LR6 or equivalent).
The measuring instrument must not be used when it is open, i.e. with an open battery compartment or
when the battery compartment cover is missing. Do not make measurements in potentially explosive areas
(Ex) or damp rooms or under unfavourable ambient conditions. Adverse ambient conditions include: Damp
or high humidity, dust and ammable gases, fumes or solvents, and thunderstorms or thunderstorm condi-
tions like strong electrostatic elds, etc.
For safety reasons, when measuring only use measuring cables or accessories that are suitable for the
specications of the multimeter.
Measurements in circuits >33 V/AC and >70 V/DC may be carried out only by specialists and trained
persons who are familiar with the pertinent regulations and the resulting dangers.
Any use other than that described above can lead to damage to the product and may involve additional
risks such as short circuits, re, electric shock etc. No part of the product may be modied or converted!
The safety instructions are to be observed without fail!
PACKAGE CONTENTS
• Multimeter
• Test leads
• Battery (Type AA)
• Operating instructions
Up-to-date Operating instructions:
1. Open www.conrad.com/downloads in a browser or scan the displayed QR
code.
2. Select document type and language and enter the item number into the
search eld. After submitting the query you can download displayed records.
DESCRIPTION OF SYMBOLS
An exclamation mark in a triangle indicates important information
contained in these operating instructions that must be observed by all means.
The lightning symbol in a triangle warns of electric shock danger or the impairment of the
electrical safety of the appliance.
The “arrow” symbol is used where special tips and notes on operation are provided.
This product has been CE tested and complies with the required European guidelines.
Class 2 insulation (double or reinforced insulation).
CAT III Measurement Category III for measuring circuits of installations in buildings (e.g. electric
sockets or sub-distributions). This category also includes all lower categories (e.g. CAT II for
measuring on electrical devices and CAT I for measuring signal and control voltages). The
measuring operation in CAT III is permitted only with probe tips with a maximum free contact
length of 4 mm or with cover caps over the probe tips.
Earth potential
SAFETY INSTRUCTIONS
Please read all the instructions before using this device, they include important informa-
tion on its correct operation.
Damages caused by failure to follow these operating instructions will void the warranty/
guarantee! We do not assume any liability for any resulting damage!
We do not assume any liability for personal injuries and material damages caused by the
improper use or non-compliance with the safety instructions! In such cases, the warranty
will be null and void.
VERSION 01/16

Chat with your Voltcraft VC-13A manual using AI

Get instant AI answers from your Voltcraft VC-13A manual

Ask anything about the Voltcraft VC-13A. Answers come from this manual, with the pages they are based on.

VC-13A Maintenance Schedule

Remind me when maintenance is due
Yearly
Calibrate the multimeter

To ensure accuracy over an extended period, the manual recommends calibrating the device once a year.

Regularly
Inspect device and leads for damage

Regularly check the technical safety of the device and measuring cables for housing damage or crimping.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend VC-13A?

Yes No
0
User Pic

anderson47

6 months ago

Is it safe to use a slower fuse with a higher voltage rating if the original fast-blow fuse is unavailable?

0
User Pic

Manual.ly

6 months ago

While using a substitute fuse may allow the device to function temporarily, it is not recommended for long-term safety. The original fuse rating ensures proper protection against overcurrent. Using a higher voltage or slower fuse could compromise safety in case of an electrical fault. We advise sourcing the correct 500V fast-blow fuse before regular use.

M: QW-35-FL
M: QW-35-FL
0
User Pic

Nikki Ross

4 months ago

Does the compact size and easy-to-read scale make this tool suitable for beginners?

M: QW-35-FL

Frequently Asked Questions

A

No, do not operate the multimeter in damp rooms, under high humidity, or when wet. Moisture can compromise safety and damage the device.

Is this answer helpful?

A

It requires one Mignon battery, specifically Type AA (UM3, LR6, or equivalent) with a voltage of 1.5 V.

Is this answer helpful?

A

Short the probes together, wait for the needle to stabilize, and adjust the 0-Ohm control to zero before measuring the component.

Is this answer helpful?

A

Yes, it is rated CAT III up to 300 V, making it suitable for household electrical installations and general hobbyist tasks.

Is this answer helpful?

A

Stop immediately, disconnect the probes, and check your polarity. Reverse the red and black leads to correct the connection.

Is this answer helpful?

A

No, unauthorized modification or conversion is strictly prohibited for safety and approval reasons (CE).

Is this answer helpful?

A

To ensure accuracy over time, the device should be calibrated at least once a year.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Shock-absorbing pointer instrument works in any orientation
  • Includes built-in battery test for 1.5 V and 9 V cells
  • Measurement Category III rated up to 300 V for safe building installation work
  • Ceramic fuse protects the mA current range from overloads
  • Calibration screw allows for precise zero adjustment before use
VS

Disadvantages

  • No automatic power-off feature in resistance mode
  • Requires manual zero adjustment for accurate readings
  • Not suitable for measuring voltages exceeding 300 V safely
  • Cannot be used in explosive atmospheres or damp rooms
  • Manual operation requires user attention to polarity and ranges
M: QW-35-FL

Product Specification

Measurement Range

max. 300V, max. 2MΩ

Package Contents

Test Leads

M: QW-35-FL

Product Description

Voltcraft VC-13A Analog Multimeter Review

The Voltcraft VC-13A Analog Multimeter is a robust and reliable tool designed for both hobbyists and professionals who require precise electrical measurements in a portable format. This device features a shock-absorbing pointer instrument that allows for readings in any operating position, making it ideal for tight spaces or awkward angles where digital displays might be hard to read. The multimeter supports Measurement Category III up to 300 V, ensuring safety during use in building installations like sockets and sub-distributions.

Equipped with a rotary switch, users can easily select between various functions including direct current (DC), alternating current (AC), resistance, and attenuation measurements. The mA current range is protected by a ceramic fuse against overload, adding an extra layer of safety. Before every measurement, the scale pointer can be adjusted using the calibration screw to ensure accuracy and prevent reading errors. The device also includes a dedicated battery test function for 1.5 V and 9 V batteries, providing clear indicators like "GOOD," "?" or "REPLACE" to assess battery health without needing external testers.

Safety is paramount with this unit. It complies with CE standards and features double insulation. Users are advised to avoid measuring voltages above 33 V AC or 70 V DC unless they are trained professionals. The device must never be operated with an open casing or missing battery cover to prevent fatal electric shocks. Additionally, it should not be used during thunderstorms or in environments with flammable gases. Regular maintenance, such as annual calibration and checking for damaged leads, ensures long-term reliability. The package includes the multimeter, test leads, an AA battery, and comprehensive instructions available online.

Key Features and Usage Notes

This analog meter excels in simplicity and durability. The large scale display makes it easy to observe trends and fluctuations in real-time. When measuring resistance, remember to zero the meter by shorting the probes and adjusting the 0-Ohm control. Always start measurements on the highest range and work down for better precision. Keep the device dry and away from strong magnetic fields to avoid distorted readings.

M: QW-35-FL

© Copyright 2026 Manual.ly