16
Remarks:
- DIP switches ds8,ds7 ,ds6 ,ds2 and ds1 are not assigned and should remain off.
- The DIP switch functions are described in 'top to bottom' order. Since the uppermost
DIP switch has the highest number (8), descriptions start with the switch numbered 5.
- These settings are not relevant for slaves. They are however relevant for followers. If
you don’t want to bother about an Inverter being a master/slave/follower then the
easiest and most straight forward way is to set all settings identically on all Inverters.
5.4.1 AES (Automatic Economy Switch)
Procedure: set ds5 to the required value:
ds5
off = AES off
on = AES on
Note: The AES option is only effective if the unit is used ‘stand alone’.
5.4.2 Inverter voltage
Procedure: set ds4 to the required value:
ds4
off = 240V
on = 230V
5.4.3 Inverter frequency
Procedure: set ds3 to the required value:
ds3
off = 60Hz
on = 50Hz
5.4.4. Important note on ds2 and ds1
If the last 3 digits of the firmware is in the 100 range (so the firmware
number is xxxx1xx (with x any number) then ds1 & ds2 can be used to set
the inverter in stand-alone, parallel or three-phase. Please consult the
appropriate manual.

Chat with your Victron Energy Phoenix Inverter 3000VA manual using AI

Get instant AI answers from your Victron Energy Phoenix Inverter 3000VA manual

Ask anything about the Victron Energy Phoenix Inverter 3000VA. Answers come from this manual, with the pages they are based on.

Phoenix Inverter 3000VA Maintenance Schedule

Remind me when maintenance is due
Yearly
Check all connections

Verify that all electrical connections are secure and intact.

Show in the manual (page 16)
Yearly
Keep device clean and dry

Avoid moisture, oil, soot, or vapors. Keep the device clean to ensure proper operation.

Show in the manual (page 16)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend Phoenix Inverter 3000VA?

Yes No

Frequently Asked Questions

A

It provides a true sine wave AC output at 230V and 50Hz in its standard configuration. The frequency can be adjusted to 60Hz, and the output voltage is adjustable within the supported range when configured correctly.

Is this answer helpful?

A

Yes. SinusMax technology is designed to deliver high start-up power, making the Phoenix range suitable for difficult loads such as compressors, electric motors, pumps, and similar appliances that need a brief surge at start-up.

Is this answer helpful?

A

Yes. Up to six identical units can be connected in parallel to increase output capacity. Compatible units can also be configured for three-phase wye operation. Matching models, equal DC cable lengths, and correct system configuration are required.

Is this answer helpful?

A

When enabled in a stand-alone configuration, Search Mode reduces no-load consumption by switching the inverter off during very low demand and briefly checking for a load every two seconds. It continues operating when the load exceeds the configured threshold.

Is this answer helpful?

A

The inverter protects against output short circuit, overload, excessive battery voltage, low battery voltage, high temperature, AC voltage at the inverter output, and excessive DC input ripple. LED indicators show operating, pre-alarm, and alarm conditions.

Is this answer helpful?

A

Install it in a dry, well-ventilated, heat-resistant location with at least 10 cm of clear space around it for cooling. Keep battery cables short to reduce voltage loss, do not mount it directly above batteries, and ensure the chassis is grounded.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • True sine wave output is suitable for sensitive electronics, motors, compressors, and other AC loads.
  • SinusMax technology provides high start-up power for demanding loads with surge requirements.
  • Up to six identical units can operate in parallel, and three-phase wye systems are supported.
  • Search Mode and AES help reduce battery drain during no-load or low-load operation.
  • Built-in protections and LED status indicators support safer operation and quicker fault diagnosis.
VS

Disadvantages

  • Professional installation, grounding, fusing, and correctly sized battery cables are required.
  • The unit must be installed in a dry, ventilated area and should not be mounted above batteries.
  • Parallel and three-phase operation require identical units, direct RJ45 links, and subsequent configuration.
  • Only one remote-control method, either a switch or control panel, can be connected to a system.
  • The supplied specifications identify Compact models up to 1600VA continuous rather than a verified 3000VA continuous model.
M: gpt-5.6-terra

Product Specification

Note

Prices partly include 0% VAT rates for AT and DE

Type

Battery inverter, with fan

Output power

3 kW

Protection rating

IP21

Ambient temperature

-40 degrees F to +149 degrees F

Dimensions

10.16 x 14.25 x 8.58 in (W x H x D)

Weight

39.68 lb

M: gpt-5.6-terra

Product Description

Victron Energy Phoenix Inverter 3000VA (230V Sinus) - Read, Download & Print Free

The Victron Energy Phoenix Inverter range is designed for dependable off-grid AC power where clean, stable electricity matters. Built around SinusMax technology, these inverters produce a true sine wave output suitable for sensitive electronics as well as demanding appliances. The 230V output supports everyday equipment in mobile, marine, backup-power, and independent energy systems.

Built for demanding loads

A major strength of the Phoenix design is its high start-up capability. Motors, compressors, pumps, and similar loads can require a substantial surge when starting. The inverter architecture is engineered to handle these brief peaks more effectively than many conventional high-frequency designs, helping connected equipment start smoothly.

Efficiency is another important advantage. Depending on the model, peak efficiency reaches up to 94%, helping preserve battery energy during regular operation. Search Mode can reduce no-load consumption by approximately 70% by checking for a connected load at intervals, while AES can lower low-load consumption by about 20% through a separate economy setting.

Flexible system configuration

Phoenix inverters are supplied ready for stand-alone operation at 230V and 50Hz. Selected settings can be adjusted for applications that need 60Hz operation or a different output voltage within the supported range. Configuration is available through DIP switches, compatible control hardware, or Victron software.

For larger installations, up to six identical inverters can be connected in parallel to increase available output capacity. A three-phase wye configuration is also supported when compatible units are correctly connected and configured. Remote on/off control is possible through an external switch or a Phoenix Inverter Control panel, while a programmable relay can be used for alarms, low-voltage signaling, or generator-start functions.

Protection and installation considerations

The inverter includes protection against overload, output short circuit, excessive temperature, high or low battery voltage, and excessive DC input ripple. LED indicators provide quick status information for inverter operation, Eco mode, pre-alarm, and alarm conditions.

Correct installation remains essential for performance and safety. The unit should be installed by a qualified electrician in a dry, well-ventilated location, close to the battery bank but never directly above it. Proper grounding, correctly sized fused cables, suitable battery capacity, and unobstructed ventilation are all important requirements.

Notes

  • The supplied specifications cover Phoenix Inverter Compact variants with 1200VA and 1600VA continuous ratings and peak power up to 3000W.
  • Select matching battery voltage, cable size, and inverter model for the intended load.
  • Use identical units only when building parallel or three-phase systems.