1. SAFETY INSTRUCTIONS
In general
Please read the documentation supplied with this product first, so that you are familiar
with the safety signs en directions before using the product.
This product is designed and tested in accordance with international standards. The
equipment should be used for the designated application only.
WARNING: DANGER OF ELECTRICAL SHOCK
The product is used in combination with a permanent energy source (battery). Even if
the equipment is switched off, a dangerous electrical voltage can occur at the input
and/or output terminals. Always switch the AC power off and disconnect the battery
before performing maintenance.
The product contains no internal user-serviceable parts. Do not remove the front panel
and do not put the product into operation unless all panels are fitted. All maintenance
should be performed by qualified personnel.
Never use the product at sites where gas or dust explosions could occur. Refer to the
specifications provided by the manufacturer of the battery to ensure that the battery is
suitable for use with this product. The battery manufacturer's safety instructions
should always be observed.
WARNING: do not lift heavy objects unassisted.
Installation
Read the installation instructions before commencing installation activities.
This product is a safety class I device (supplied with a ground terminal for safety
purposes). The chassis must be grounded. A grounding point is located on the
outside of the product. If it can be assumed that the grounding protection is damaged,
the product should be taken out of operation and prevented from accidentally being
put into operation again; contact qualified maintenance personnel.
Ensure that the connection cables are provided with fuses and circuit breakers. Never
replace a protective device by a component of a different type. Refer to the manual for
the correct part.
Check before switching the device on whether the available voltage source conforms
to the configuration settings of the product as described in the manual.
Ensure that the equipment is used under the correct operating conditions. Never
operate it in a wet or dusty environment.
Ensure that there is always sufficient free space around the product for ventilation,
and that ventilation openings are not blocked.

Chat with your Victron Energy Phoenix Inverter 3000VA manual using AI

Get instant AI answers from your Victron Energy Phoenix Inverter 3000VA manual

Ask anything about the Victron Energy Phoenix Inverter 3000VA. Answers come from this manual, with the pages they are based on.

Phoenix Inverter 3000VA Maintenance Schedule

Remind me when maintenance is due
Yearly
Check all connections

Verify that all electrical connections are secure and intact.

Show in the manual (page 16)
Yearly
Keep device clean and dry

Avoid moisture, oil, soot, or vapors. Keep the device clean to ensure proper operation.

Show in the manual (page 16)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend Phoenix Inverter 3000VA?

Yes No

Frequently Asked Questions

A

It provides a true sine wave AC output at 230V and 50Hz in its standard configuration. The frequency can be adjusted to 60Hz, and the output voltage is adjustable within the supported range when configured correctly.

Is this answer helpful?

A

Yes. SinusMax technology is designed to deliver high start-up power, making the Phoenix range suitable for difficult loads such as compressors, electric motors, pumps, and similar appliances that need a brief surge at start-up.

Is this answer helpful?

A

Yes. Up to six identical units can be connected in parallel to increase output capacity. Compatible units can also be configured for three-phase wye operation. Matching models, equal DC cable lengths, and correct system configuration are required.

Is this answer helpful?

A

When enabled in a stand-alone configuration, Search Mode reduces no-load consumption by switching the inverter off during very low demand and briefly checking for a load every two seconds. It continues operating when the load exceeds the configured threshold.

Is this answer helpful?

A

The inverter protects against output short circuit, overload, excessive battery voltage, low battery voltage, high temperature, AC voltage at the inverter output, and excessive DC input ripple. LED indicators show operating, pre-alarm, and alarm conditions.

Is this answer helpful?

A

Install it in a dry, well-ventilated, heat-resistant location with at least 10 cm of clear space around it for cooling. Keep battery cables short to reduce voltage loss, do not mount it directly above batteries, and ensure the chassis is grounded.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • True sine wave output is suitable for sensitive electronics, motors, compressors, and other AC loads.
  • SinusMax technology provides high start-up power for demanding loads with surge requirements.
  • Up to six identical units can operate in parallel, and three-phase wye systems are supported.
  • Search Mode and AES help reduce battery drain during no-load or low-load operation.
  • Built-in protections and LED status indicators support safer operation and quicker fault diagnosis.
VS

Disadvantages

  • Professional installation, grounding, fusing, and correctly sized battery cables are required.
  • The unit must be installed in a dry, ventilated area and should not be mounted above batteries.
  • Parallel and three-phase operation require identical units, direct RJ45 links, and subsequent configuration.
  • Only one remote-control method, either a switch or control panel, can be connected to a system.
  • The supplied specifications identify Compact models up to 1600VA continuous rather than a verified 3000VA continuous model.
M: gpt-5.6-terra

Product Specification

Note

Prices partly include 0% VAT rates for AT and DE

Type

Battery inverter, with fan

Output power

3 kW

Protection rating

IP21

Ambient temperature

-40 degrees F to +149 degrees F

Dimensions

10.16 x 14.25 x 8.58 in (W x H x D)

Weight

39.68 lb

M: gpt-5.6-terra

Product Description

Victron Energy Phoenix Inverter 3000VA (230V Sinus) - Read, Download & Print Free

The Victron Energy Phoenix Inverter range is designed for dependable off-grid AC power where clean, stable electricity matters. Built around SinusMax technology, these inverters produce a true sine wave output suitable for sensitive electronics as well as demanding appliances. The 230V output supports everyday equipment in mobile, marine, backup-power, and independent energy systems.

Built for demanding loads

A major strength of the Phoenix design is its high start-up capability. Motors, compressors, pumps, and similar loads can require a substantial surge when starting. The inverter architecture is engineered to handle these brief peaks more effectively than many conventional high-frequency designs, helping connected equipment start smoothly.

Efficiency is another important advantage. Depending on the model, peak efficiency reaches up to 94%, helping preserve battery energy during regular operation. Search Mode can reduce no-load consumption by approximately 70% by checking for a connected load at intervals, while AES can lower low-load consumption by about 20% through a separate economy setting.

Flexible system configuration

Phoenix inverters are supplied ready for stand-alone operation at 230V and 50Hz. Selected settings can be adjusted for applications that need 60Hz operation or a different output voltage within the supported range. Configuration is available through DIP switches, compatible control hardware, or Victron software.

For larger installations, up to six identical inverters can be connected in parallel to increase available output capacity. A three-phase wye configuration is also supported when compatible units are correctly connected and configured. Remote on/off control is possible through an external switch or a Phoenix Inverter Control panel, while a programmable relay can be used for alarms, low-voltage signaling, or generator-start functions.

Protection and installation considerations

The inverter includes protection against overload, output short circuit, excessive temperature, high or low battery voltage, and excessive DC input ripple. LED indicators provide quick status information for inverter operation, Eco mode, pre-alarm, and alarm conditions.

Correct installation remains essential for performance and safety. The unit should be installed by a qualified electrician in a dry, well-ventilated location, close to the battery bank but never directly above it. Proper grounding, correctly sized fused cables, suitable battery capacity, and unobstructed ventilation are all important requirements.

Notes

  • The supplied specifications cover Phoenix Inverter Compact variants with 1200VA and 1600VA continuous ratings and peak power up to 3000W.
  • Select matching battery voltage, cable size, and inverter model for the intended load.
  • Use identical units only when building parallel or three-phase systems.