12
If the pump is to be put out of operation for some extended period of time, it should
be emptied completely in by opening the water drain screw (10). Subsequently,
please flush the pump with clean water. Then allow the pump body to dry completely
in order to prevent corrosion damage.
Water left in the pump may freeze in case of frost and thus cause considerable
damage. Please store the pump in a dry, frost- protected place.
In the case of malfunction, you should first of all check whether it was caused by an
operating error or some other reason which cannot be attributed to a defect of the
device - for instance a power failure.
The list below shows some possible malfunctions of the device, possible causes and
tips on their elimination. All the measures referred to may only be carried out with the
pump being separated from the electrical mains. If you yourself feel unable to elimi-
nate any of these malfunctions, please contact the customer service department or
your point of sales. Any repair beyond the scope specified below must only be per-
formed by qualified staff. Please bear in mind that all warranty claims will become
void in the case of damage caused by inappropriate repair attempts, and that we de-
cline any liability for any ensuing damage.
Malfunction
Possible Cause
Elimination
1.
The pump is not
discharging any liq-
uid, the motor is not
running.
1.
2.
3.
4.
5.
6.
7.
No current.
Thermal motor protection feature has trig-
gered.
The capacitor is defective.
The motor shaft is jamming.
The electronic pump control is defective.
The anti-dry-running feature is activated (red
“Fehler” (Error) indicator lights up).
The difference in height between the
pump and the point of withdrawal, limited
to max. 16 m by the pre-set value (Cut In
pressure 1,6 bar), has been exceeded.
1.
2.
3.
4.
5.
6.
7.
Please use a device complying with GS (German
technical supervisory authority) to check for the
presence of voltage (safety information to be ob-
served!). Please verify the correct position of the
plug.
Separate the pump from the electrical mains, allow
the system to cool down, eliminate cause.
Please contact the customer service department.
Check the cause; eliminate the reason for the jam-
ming of the pump.
Please contact the customer service department.
Refer to section 2.2 and 2.3
The switch-on pressure of the electronic pump
control is to be increased., see chapter 8.4.
2.
The motor is run-
ning, but the pump
is not discharging
any liquid.
1.
2.
3.
The pump housing is not filled with liquid.
Air penetrates into the intake line.
Suction height and/or discharge height too
great.
1.
2.
a)
b)
c)
d)
3.
Fill the pump housing with liquid (please refer to
”Putting into operation” section).
Check to make sure that:
the connection points of the intake line are tight;
the inlet opening of the intake line including the
check valve (non-return valve) are immersed into
the liquids being discharged;
the check valve (non-return valve) with the filter is
tight and not jammed;
no siphons (i.e. permanently liquid-filled loops),
kinks, counter-slopes or narrow spots are present
along the intake lines.
Change the arrangement of the installation so that
the suction height and/or discharge height will not
exceed the max. value.
29

Chat with your T.I.P. HWA 3000 EPF manual using AI

Get instant AI answers from your T.I.P. HWA 3000 EPF manual

Ask anything about the T.I.P. HWA 3000 EPF. Answers come from this manual, with the pages they are based on.

HWA 3000 EPF Maintenance Schedule

Before each use
Inspect pump visually before each use

Check the mains connection line and plug for damage. Ensure all screws are tight and connections are in perfect condition.

Show in the manual (page 26)
After extended storage
Empty and flush pump if stored long-term

Open drain screw to empty pump, flush with clean water, and dry completely to prevent corrosion or frost damage.

Show in the manual (page 31)
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend HWA 3000 EPF?

Yes No

Frequently Asked Questions

A

Open the filter lid counter-clockwise, insert a tool to hold the check valve open, and fill the housing with water until full. Close the lid securely before starting the pump.

Is this answer helpful?

A

Yes, it can pump moderately dirty water containing solid particles up to 3 mm in size, provided the inlet filter is kept clean.

Is this answer helpful?

A

The electronic control detects low flow and activates the anti-dry-running protection, stopping the pump and lighting the error LED to prevent damage.

Is this answer helpful?

A

No, the T.I.P. HWA 3000 EPF is strictly for domestic water supply and irrigation, not for use in swimming pools or public drinking water networks.

Is this answer helpful?

A

Turn off the pump, hold the CUT-IN button for 3 seconds until the light blinks, then press it repeatedly to increase the pressure setting before saving.

Is this answer helpful?

A

Yes, by holding the ON/Restart button for 5 seconds while the unit is off, you can deactivate the leak detection function if needed for specific operations.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Self-priming capability simplifies installation and reduces setup time significantly.
  • Electronic control provides automatic start-stop functionality based on water usage.
  • Integrated thermal protection safeguards the motor against overheating and dry running.
  • High maximum flow rate of 6,000 liters per hour suits large households and gardens.
  • Leak detection feature helps identify minor system losses early to prevent waste.
VS

Disadvantages

  • Requires manual priming with water before the initial startup phase.
  • Not suitable for pumping saltwater or hazardous chemical liquids.
  • Maximum suction height is limited to 9 meters under ideal conditions.
  • Noise level may be noticeable in very quiet residential environments.
  • Requires a dedicated RCD circuit breaker for safe electrical connection.
M: QW-35-FL

Product Specification

Power

1500W

Flow Rate

1585 gal/h

Head

147.64 ft

Suction Height

29.53 ft

Pressure

65.27 psi

Pressure Connection

1"

Suction Connection

1 1/4"

Features

without tank

Cable Length

4.92 ft

Weight

29.1 lbs

M: QW-35-FL

Product Description

T.I.P. HWA 3000 EPF Electric Home Water System: Your Ultimate Water Solution

Welcome to the world of efficient water management with the T.I.P. HWA 3000 EPF Electric Home Water System. This robust automatic booster set is designed specifically for homeowners who demand reliability and performance in their daily water supply needs. Whether you are looking to automate your garden irrigation, draw water from a private well, or ensure consistent pressure for household appliances, this system delivers seamless operation.

The T.I.P. HWA 3000 EPF stands out as a portable, self-priming electric pump equipped with advanced electronic control. It intelligently manages water flow by automatically switching on when a tap is opened and shutting off when the desired pressure is reached. This feature not only saves energy but also extends the lifespan of the motor by preventing unnecessary running. The system handles clean water and moderately dirty water containing small solids up to 3 mm, making it versatile for various domestic applications like filling cisterns, ponds, or maintaining garden sprinklers.

Safety is at the core of its design. The unit includes a thermal motor protection that prevents overheating during dry running conditions, ensuring your investment remains safe even if water flow is interrupted. The integrated filter protects internal components from debris, while the leak detection feature helps identify minor system losses before they become major issues. With a maximum flow rate of 6,000 liters per hour and a delivery height of up to 45 meters, this powerhouse meets the demands of large homes and extensive gardens alike.

Installation is straightforward thanks to clear guidelines and durable construction materials. The pump operates quietly, with a guaranteed sound power level of 82 dB(A), minimizing noise pollution around your property. Its compact dimensions allow for easy placement in utility rooms, garages, or outdoor sheds, provided the area remains dry and frost-free. By choosing the T.I.P. HWA 3000 EPF, you are investing in a system that combines German engineering precision with user-friendly automation.

Important Notes

  • Always ensure the pump is primed with water before the first start-up to prevent dry running damage.
  • Use a residual current device (RCD) with a rated residual operating current not exceeding 30 mA for electrical safety.
  • Regular maintenance, such as checking seals and cleaning filters, ensures optimal performance and longevity.
  • Do not use the pump for saltwater, flammable liquids, or hazardous substances.
  • Keep the unit away from direct rain and store it indoors during winter to prevent freezing.