Manual.ly Logo

T.I.P. HWA 3000 EPF Manual

0.0 · 0 Ratings

PDF manual · 84 Pages

English

M: QW-35-FL
page

/ 84

Loading...
ece58915ac04d000481e8af057a43b7e5361 page 14
Translation of the Original Operating Instructions
1
Dear customer,
Congratulation for buying your new device from T.I.P.!
We hope you will enjoy your new device!
Table of contents
1. General safety information ............................................................................................. 1
2. Technical Data ............................................................................................................... 2
3. Range of use .................................................................................................................. 3
4. Scope of delivery ............................................................................................................ 4
5. Installation ...................................................................................................................... 4
6. Electrical connection ...................................................................................................... 6
7. Putting into operation ..................................................................................................... 6
8. Functioning of the electronic pump control system ......................................................... 9
9. Maintenance and troubleshooting................................................................................. 11
10. Warranty ...................................................................................................................... 13
11. How to order spare parts .............................................................................................. 14
12. Service ......................................................................................................................... 14
1. General safety information
Please read through these operating instructions carefully and make yourself
conversant with the control elements and the proper use of this product. We shall
not be liable in the case of damage caused as a result of the non-observance of
instructions and provisions of the present operating instructions. Any damage
caused as a result of the non-observance of the instructions and regulations con-
tained in the present operating instructions shall not be covered by the warranty
terms. Please keep these operating instructions in a safe place and hand them
on together with the device should you ever dispose of it.
With the contents of this manual unfamiliar people should not
use this device.
The pump must not be used by children.
The pump may be used by persons with reduced physical,
sensory or mental capabilities or lack of experience and / or
knowledge if they have been supervised or instructed in the
safe use of the equipment and have understood the resulting
hazards.
Children are not allowed to play with the device.
Keep the appliance and its cord out of reach of children.
The pump must not be used when people or animals are in
the water.
18

Chat with your T.I.P. HWA 3000 EPF manual using AI

Get instant AI answers from your T.I.P. HWA 3000 EPF manual

Ask anything about the T.I.P. HWA 3000 EPF. Answers come from this manual, with the pages they are based on.

HWA 3000 EPF Maintenance Schedule

Before each use
Inspect pump visually before each use

Check the mains connection line and plug for damage. Ensure all screws are tight and connections are in perfect condition.

Show in the manual (page 26)
After extended storage
Empty and flush pump if stored long-term

Open drain screw to empty pump, flush with clean water, and dry completely to prevent corrosion or frost damage.

Show in the manual (page 31)
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend HWA 3000 EPF?

Yes No

Frequently Asked Questions

A

Open the filter lid counter-clockwise, insert a tool to hold the check valve open, and fill the housing with water until full. Close the lid securely before starting the pump.

Is this answer helpful?

A

Yes, it can pump moderately dirty water containing solid particles up to 3 mm in size, provided the inlet filter is kept clean.

Is this answer helpful?

A

The electronic control detects low flow and activates the anti-dry-running protection, stopping the pump and lighting the error LED to prevent damage.

Is this answer helpful?

A

No, the T.I.P. HWA 3000 EPF is strictly for domestic water supply and irrigation, not for use in swimming pools or public drinking water networks.

Is this answer helpful?

A

Turn off the pump, hold the CUT-IN button for 3 seconds until the light blinks, then press it repeatedly to increase the pressure setting before saving.

Is this answer helpful?

A

Yes, by holding the ON/Restart button for 5 seconds while the unit is off, you can deactivate the leak detection function if needed for specific operations.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Self-priming capability simplifies installation and reduces setup time significantly.
  • Electronic control provides automatic start-stop functionality based on water usage.
  • Integrated thermal protection safeguards the motor against overheating and dry running.
  • High maximum flow rate of 6,000 liters per hour suits large households and gardens.
  • Leak detection feature helps identify minor system losses early to prevent waste.
VS

Disadvantages

  • Requires manual priming with water before the initial startup phase.
  • Not suitable for pumping saltwater or hazardous chemical liquids.
  • Maximum suction height is limited to 9 meters under ideal conditions.
  • Noise level may be noticeable in very quiet residential environments.
  • Requires a dedicated RCD circuit breaker for safe electrical connection.
M: QW-35-FL

Product Specification

Power

1500W

Flow Rate

1585 gal/h

Head

147.64 ft

Suction Height

29.53 ft

Pressure

65.27 psi

Pressure Connection

1"

Suction Connection

1 1/4"

Features

without tank

Cable Length

4.92 ft

Weight

29.1 lbs

M: QW-35-FL

Product Description

T.I.P. HWA 3000 EPF Electric Home Water System: Your Ultimate Water Solution

Welcome to the world of efficient water management with the T.I.P. HWA 3000 EPF Electric Home Water System. This robust automatic booster set is designed specifically for homeowners who demand reliability and performance in their daily water supply needs. Whether you are looking to automate your garden irrigation, draw water from a private well, or ensure consistent pressure for household appliances, this system delivers seamless operation.

The T.I.P. HWA 3000 EPF stands out as a portable, self-priming electric pump equipped with advanced electronic control. It intelligently manages water flow by automatically switching on when a tap is opened and shutting off when the desired pressure is reached. This feature not only saves energy but also extends the lifespan of the motor by preventing unnecessary running. The system handles clean water and moderately dirty water containing small solids up to 3 mm, making it versatile for various domestic applications like filling cisterns, ponds, or maintaining garden sprinklers.

Safety is at the core of its design. The unit includes a thermal motor protection that prevents overheating during dry running conditions, ensuring your investment remains safe even if water flow is interrupted. The integrated filter protects internal components from debris, while the leak detection feature helps identify minor system losses before they become major issues. With a maximum flow rate of 6,000 liters per hour and a delivery height of up to 45 meters, this powerhouse meets the demands of large homes and extensive gardens alike.

Installation is straightforward thanks to clear guidelines and durable construction materials. The pump operates quietly, with a guaranteed sound power level of 82 dB(A), minimizing noise pollution around your property. Its compact dimensions allow for easy placement in utility rooms, garages, or outdoor sheds, provided the area remains dry and frost-free. By choosing the T.I.P. HWA 3000 EPF, you are investing in a system that combines German engineering precision with user-friendly automation.

Important Notes

  • Always ensure the pump is primed with water before the first start-up to prevent dry running damage.
  • Use a residual current device (RCD) with a rated residual operating current not exceeding 30 mA for electrical safety.
  • Regular maintenance, such as checking seals and cleaning filters, ensures optimal performance and longevity.
  • Do not use the pump for saltwater, flammable liquids, or hazardous substances.
  • Keep the unit away from direct rain and store it indoors during winter to prevent freezing.
M: QW-35-FL

© Copyright 2026 Manual.ly