5.5. Using the pump for garden ponds and similar places
Operating the pump next to garden ponds and similar places is generally only admissible if no
persons are in contact with the water.
If the pump is used for garden ponds and similar places it has to be operated using a residual current circuit-
breaker (FI switch) with a nominal trigger current of ≤ 30mA (DIN VDE 0100-702 and 0100-738). Please ask your
electrical services provider whether your installation site complies with this condition.
The pump must not be used in such locations unless it is set up firmly and flood-proof, a minimum distance of two
metres away from the border of the water body and secured against falling into the water by a solid holding
device. For this purpose the device is to be bolted down firmly to the ground at the fastening points provided
(please refer to the chapter titled "Stationary installation").
6. Electrical connection
The unit is equipped with a mains connection cable and a mains plug. It must only be replaced by qualified staff to
avoid any danger. Please do not use the mains connection cable to carry the pump, and do not use this cable to
pull off the plug from the socket, either. Protect the mains connection cable and mains plug from heat, oil or sharp
edges.
The values stated in the technical details have to correspond to the mains voltage. The person
responsible for the installation has to make sure that the electrical connection is earthed in
compliance with the applicable standards.
The electrical connection has to be equipped with a highly sensitive residual current circuit-
breaker (FI switch): ∆ = 30 mA (DIN VDE 0100-739).
Only use an extension cable with a cable section (3 x 1.0 mm²) and rubber sheath which at
least corresponds to that of the unit's own connection cable (see "Technical data", cable type)
and which is labelled with the relevant abbreviation according to the VDE (German
Association for Electrical, Electronic & Information Technologies). The mains plug and other
connections must be splash-proof.
7. Putting into operation
Please observe the illustrations, too, which are contained as an attachment at the end of the present operating
instructions. The numeric and other details included in brackets below refer to these illustrations.
Prior to putting the pump into operation for the very first time, the pump housing
should be fully vented - i.e. filled with water - even in the case of self-priming
units. If this venting is omitted, the pump will not suck in the liquid to be
discharged. It is highly recommendable, yet not mandatory, to vent the intake
line as well, i.e. to fill it with water.
The pump must only be operated in the performance range indicated on the type plate.
Dry-running - i.e. operating the pump without discharging water - is to be avoided since the
absence of water may cause the pump to run hot. This may cause considerable damage on
the device. Moreover, this means that very hot water will be enclosed within the system so that
there is a hazard of scalding. If the pump has run hot, please pull off the mains plug and allow
the system to cool down.
Please do not expose the pump to moisture (e.g. when operating sprinklers). Do not expose
the unit to rain, either. Make sure that no dripping connections are located above the pump.
The pump should not be used in wet or moist environments. Make sure that the pump and the
electrical plug connections are arranged in a flood-proof place.
The pump must not be running with the feeder line closed.
As long as the device is connected to the electrical mains, one must never reach with one’s
hands into the opening of the pump.
12

Chat with your T.I.P. Garden Pump manual using AI

Get instant AI answers from your T.I.P. Garden Pump manual

Ask anything about the T.I.P. Garden Pump. Answers come from this manual, with the pages they are based on.

Garden Pump Maintenance Schedule

Before each use
Visual inspection of pump and cable

Inspect the pump visually before every use, especially the mains connection line and plug. Ensure all screws are tight and connections are in perfect condition.

Show in the manual (page 15)
Long term storage
Empty and dry pump

If not used for an extended period, open drain screw to empty water, flush with clean water, and let body dry completely to prevent corrosion.

Show in the manual (page 15)
M: QW-35-FL

Ask a Question

0/1000

Do you recommend Garden Pump?

Yes No

Frequently Asked Questions

A

It can pump clear, clean, or moderately dirty water with solid particles up to 3 mm. Do not use it for saltwater, sewage, flammable, corrosive, explosive, or other hazardous liquids.

Is this answer helpful?

A

The Garten-Jet 750 is rated at 600 W with a maximum flow of 2,800 l/h, 4.2 bar pressure, and 42 m delivery height. The 800 W Garten-Jet 1000 Plus reaches 3,500 l/h, 4.6 bar, and 46 m.

Is this answer helpful?

A

Yes. Fill the pump housing completely with water before initial operation or restarting after a long pause. Filling the suction line is strongly recommended because it can shorten the priming time.

Is this answer helpful?

A

Yes, only when no people or animals are in contact with the water. Install it securely, flood-proof, and at least two metres from the water edge. Use an electrical supply protected by a 30 mA RCD.

Is this answer helpful?

A

Use a suction hose matching the 1-inch suction connection. Its intake should include a filter and non-return valve. Keep the intake at least 0.3 m below the water surface and away from the bottom.

Is this answer helpful?

A

Common causes include an unfilled pump housing, air leaks in the suction line, a blocked or faulty non-return valve, or excessive suction and delivery height. Check seals, hose routing, immersion depth, and priming.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • Self-priming design supports garden irrigation, water transfer, drainage, and cleaning tasks.
  • Garten-Jet 1000 Plus delivers up to 3,500 l/h, 4.6 bar pressure, and 46 m delivery height.
  • Both models accept particles up to 3 mm and can draw water from up to 9 m depth.
  • Integrated thermal motor protection helps prevent damage caused by overload.
  • Optional controllers can automate water delivery and may add dry-run protection.
VS

Disadvantages

  • Not suitable for swimming pools, public drinking-water systems, commercial use, or continuous circulation.
  • Pump housing must be filled with water before first use and after extended storage.
  • Cannot pump saltwater, sewage, flammable, corrosive, explosive, or hazardous liquids.
  • Requires a dry, frost-protected installation area and a 30 mA RCD-protected electrical supply.
  • The 1.5 m power cable may require a suitable splash-protected extension cable.
M: gpt-5.6-terra

Product Specification

Features

tankless

M: gpt-5.6-terra

Product Description

T.I.P. Electric Garden Pump Manual: Reliable Water Movement for Home Gardens

The T.I.P. Electric Garden Pump range is designed for practical water supply jobs around the home and garden. Available in Garten-Jet 750 and Garten-Jet 1000 Plus versions, these self-priming electric pumps can move clear, clean, or moderately dirty water containing particles up to 3 mm. They are suitable for irrigation, draining containers, drawing water from wells or cisterns, emptying ponds, and cleaning patios or paths.

The T.I.P. Electric Garden Pump Manual highlights a straightforward setup process built around safe positioning, airtight pipework, and correct priming. Before starting, the pump housing must be filled completely with water. Filling the suction line is also recommended to speed up priming. A suction hose with a filter and non-return valve helps prevent debris from entering the system and stops water from draining back after shutdown.

Performance Options

The Garten-Jet 750 uses a 600 W motor and offers a maximum flow rate of 2,800 litres per hour. It can reach a maximum pressure of 4.2 bar and a delivery height of 42 m. The Garten-Jet 1000 Plus increases output with an 800 W motor, a maximum flow rate of 3,500 litres per hour, 4.6 bar maximum pressure, and a 46 m delivery height. Both models support a maximum suction height of 9 m and use 1-inch suction and pressure connections.

These compact pumps measure 36 x 17.5 x 24.5 cm, making them convenient for fixed garden installations where space is limited. They should be placed upright on a solid, dry, level surface with adequate motor ventilation. For a permanent installation, an anti-vibration layer can help reduce operating vibration.

Safe and Efficient Operation

The pumps are intended for private household use, not commercial duty or continuous circulation. They must not be used for saltwater, sewage, flammable, corrosive, explosive, or hazardous liquids. Water temperature must stay between 2 C and 35 C, while ambient conditions should remain between 5 C and 40 C.

Electrical safety is essential. The pump requires a grounded 230 V, 50 Hz supply protected by a 30 mA residual current device. Keep plugs and electrical connections dry, avoid rain exposure, and never run the pump dry. Integrated thermal motor protection switches the motor off during overload and allows restart after cooling.

Note: Drain, rinse, and dry the pump before long storage periods. Keeping it in a dry, frost-protected location helps prevent freeze damage and corrosion.

For users who want tap-like water access, compatible mechanical or electronic controllers can automate pump operation. Some optional controllers also provide dry-run protection, adding convenience and helping protect the pump during low-water conditions.

M: gpt-5.6-terra

© Copyright 2026 Manual.ly