Manual.ly Logo

T.I.P. Garden Pump Manual

0.0 · 0 Ratings

PDF manual · 140 Pages

English

M: gpt-5.6-terra
page

/ 140

Loading...
ead3b1003a8551f04d1fe6364c07fcedef35 page c
1
Dear customer,
Congratulation for buying your new device from T.I.P.!
Like all our products, this one, too, was developed using the latest technological knowledge. The device was
manufactured and assembled on the basis of state-of-the-art pump technology using most reliable electrical or
electronic components which ensure a high level of quality and a long life of your new product.
Please read through these operating instructions carefully to make sure that you can fully benefit from all features.
Some explanatory illustrations can be found at the end of these operating instructions.
We hope you will enjoy your new device!
Table of contents
1. General safety information ............................................................................................................................. 1
2. Range of use .................................................................................................................................................. 2
3. Technical Data ............................................................................................................................................... 2
4. Scope of delivery ........................................................................................................................................... 2
5. Installation ...................................................................................................................................................... 3
6. Electrical connection ...................................................................................................................................... 4
7. Putting into operation ..................................................................................................................................... 4
8. Automation with special accessories ............................................................................................................. 5
9. Maintenance and troubleshooting .................................................................................................................. 5
10. Warranty ........................................................................................................................................................ 6
11. How to order spare parts ................................................................................................................................ 7
12. Service ........................................................................................................................................................... 7
Annex: Illustrations
1. General safety information
Please read through these operating instructions carefully and make yourself conversant with the control
elements and the proper use of this product. We shall not be liable in the case of damage caused as a result of
the non-observance of instructions and provisions of the present operating instructions. Any damage caused as a
result of the non-observance of the instructions and regulations contained in the present operating instructions
shall not be covered by the warranty terms. Please keep these operating instructions in a safe place and hand
them on together with the device should you ever dispose of it.
Persons not conversant with the contents of these operating instructions must not
use this device.
The pump must not be used by children.
The pump may be used by persons with reduced physical, sensory or mental
capabilities or lack of experience and / or knowledge if they have been supervised or
instructed in the safe use of the equipment and have understood the resulting
hazards. Children are not allowed to play with the device. Keep the appliance and its
cord out of reach of children.
The pump must not be used when people or animals are in the water.
The pump must be supplied through a residual current device (RCD) having a rated
residual operating current not exceeding 30mA.
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
Notes and instructions with the following symbols require particular attention:
Any non-observance of these instructions involves the danger of bodily harm to people and/or
damage to property.
Any non-observance of this instruction bears the risk of an electrical shock which may cause
damage to persons or property.
Please inspect the device for damage occurred during transportation. In case of damage, the retailer has to be
informed immediately, at the latest within 8 days after the date of purchase.
9

Chat with your T.I.P. Garden Pump manual using AI

Get instant AI answers from your T.I.P. Garden Pump manual

Ask anything about the T.I.P. Garden Pump. Answers come from this manual, with the pages they are based on.

Garden Pump Maintenance Schedule

Before each use
Visual inspection of pump and cable

Inspect the pump visually before every use, especially the mains connection line and plug. Ensure all screws are tight and connections are in perfect condition.

Show in the manual (page 15)
Long term storage
Empty and dry pump

If not used for an extended period, open drain screw to empty water, flush with clean water, and let body dry completely to prevent corrosion.

Show in the manual (page 15)
M: QW-35-FL

Ask a Question

0/1000

Do you recommend Garden Pump?

Yes No

Frequently Asked Questions

A

It can pump clear, clean, or moderately dirty water with solid particles up to 3 mm. Do not use it for saltwater, sewage, flammable, corrosive, explosive, or other hazardous liquids.

Is this answer helpful?

A

The Garten-Jet 750 is rated at 600 W with a maximum flow of 2,800 l/h, 4.2 bar pressure, and 42 m delivery height. The 800 W Garten-Jet 1000 Plus reaches 3,500 l/h, 4.6 bar, and 46 m.

Is this answer helpful?

A

Yes. Fill the pump housing completely with water before initial operation or restarting after a long pause. Filling the suction line is strongly recommended because it can shorten the priming time.

Is this answer helpful?

A

Yes, only when no people or animals are in contact with the water. Install it securely, flood-proof, and at least two metres from the water edge. Use an electrical supply protected by a 30 mA RCD.

Is this answer helpful?

A

Use a suction hose matching the 1-inch suction connection. Its intake should include a filter and non-return valve. Keep the intake at least 0.3 m below the water surface and away from the bottom.

Is this answer helpful?

A

Common causes include an unfilled pump housing, air leaks in the suction line, a blocked or faulty non-return valve, or excessive suction and delivery height. Check seals, hose routing, immersion depth, and priming.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • Self-priming design supports garden irrigation, water transfer, drainage, and cleaning tasks.
  • Garten-Jet 1000 Plus delivers up to 3,500 l/h, 4.6 bar pressure, and 46 m delivery height.
  • Both models accept particles up to 3 mm and can draw water from up to 9 m depth.
  • Integrated thermal motor protection helps prevent damage caused by overload.
  • Optional controllers can automate water delivery and may add dry-run protection.
VS

Disadvantages

  • Not suitable for swimming pools, public drinking-water systems, commercial use, or continuous circulation.
  • Pump housing must be filled with water before first use and after extended storage.
  • Cannot pump saltwater, sewage, flammable, corrosive, explosive, or hazardous liquids.
  • Requires a dry, frost-protected installation area and a 30 mA RCD-protected electrical supply.
  • The 1.5 m power cable may require a suitable splash-protected extension cable.
M: gpt-5.6-terra

Product Specification

Features

tankless

M: gpt-5.6-terra

Product Description

T.I.P. Electric Garden Pump Manual: Reliable Water Movement for Home Gardens

The T.I.P. Electric Garden Pump range is designed for practical water supply jobs around the home and garden. Available in Garten-Jet 750 and Garten-Jet 1000 Plus versions, these self-priming electric pumps can move clear, clean, or moderately dirty water containing particles up to 3 mm. They are suitable for irrigation, draining containers, drawing water from wells or cisterns, emptying ponds, and cleaning patios or paths.

The T.I.P. Electric Garden Pump Manual highlights a straightforward setup process built around safe positioning, airtight pipework, and correct priming. Before starting, the pump housing must be filled completely with water. Filling the suction line is also recommended to speed up priming. A suction hose with a filter and non-return valve helps prevent debris from entering the system and stops water from draining back after shutdown.

Performance Options

The Garten-Jet 750 uses a 600 W motor and offers a maximum flow rate of 2,800 litres per hour. It can reach a maximum pressure of 4.2 bar and a delivery height of 42 m. The Garten-Jet 1000 Plus increases output with an 800 W motor, a maximum flow rate of 3,500 litres per hour, 4.6 bar maximum pressure, and a 46 m delivery height. Both models support a maximum suction height of 9 m and use 1-inch suction and pressure connections.

These compact pumps measure 36 x 17.5 x 24.5 cm, making them convenient for fixed garden installations where space is limited. They should be placed upright on a solid, dry, level surface with adequate motor ventilation. For a permanent installation, an anti-vibration layer can help reduce operating vibration.

Safe and Efficient Operation

The pumps are intended for private household use, not commercial duty or continuous circulation. They must not be used for saltwater, sewage, flammable, corrosive, explosive, or hazardous liquids. Water temperature must stay between 2 C and 35 C, while ambient conditions should remain between 5 C and 40 C.

Electrical safety is essential. The pump requires a grounded 230 V, 50 Hz supply protected by a 30 mA residual current device. Keep plugs and electrical connections dry, avoid rain exposure, and never run the pump dry. Integrated thermal motor protection switches the motor off during overload and allows restart after cooling.

Note: Drain, rinse, and dry the pump before long storage periods. Keeping it in a dry, frost-protected location helps prevent freeze damage and corrosion.

For users who want tap-like water access, compatible mechanical or electronic controllers can automate pump operation. Some optional controllers also provide dry-run protection, adding convenience and helping protect the pump during low-water conditions.

M: gpt-5.6-terra

© Copyright 2026 Manual.ly