4
Shall the pump continue to suck beyond the automatic cut-out level, the flow switch has to be operated manually,
e.g. by holding it in upright position. Only in this operation mode, the minimum suction height can be reached as
listed in the tec. data box. In this condition the pump has to be under constant supervision to avoid dry running.
6. Electrical connection
The unit is equipped with a mains connection cable and a mains plug. It must only be replaced by qualified staff to
avoid any danger. Please do not use the mains connection cable to carry the pump, and do not use this cable to
pull off the plug from the socket, either. Protect the mains connection cable and mains plug from heat, oil or sharp
edges.
The values stated in the technical details have to correspond to the mains voltage. The person
responsible for the installation has to make sure that the electrical connection is earthed in
compliance with the applicable standards.
The electrical connection has to be equipped with a highly sensitive residual current circuit-
breaker (FI switch): ∆ = 30 mA (DIN VDE 0100-739).
Only use an extension cable with a cable section (3 x 1.0 mm²) and rubber sheath which at
least corresponds to that of the unit's own connection cable (see "Technical data", cable type)
and which is labelled with the relevant abbreviation according to the VDE (German
Association for Electrical, Electronic & Information Technologies). The mains plug and other
connections must be splashproof.
7. Putting into operation
Nobody must be in the water while the pump is running.
The pump must only be operated in the performance range indicated on the type plate.
Dry-running - i.e. operating the pump without discharging water - is to be avoided since the
absence of water may cause the pump to run hot. This may cause considerable damage on
the device.
Please make sure that the electrical plug connections are in the flood-proof area.
As long as the device is connected to the electrical mains, one must never reach with one’s
hands into the opening of the pump.
Please inspect the pump visually prior to each use. This applies in particular to the mains connection line and the
mains plug. Make sure that all screws are firmly tightened, and verify the perfect condition of all connections. A
damaged pump must not be used. In any case of damage, the pump has to be inspected by qualified service
staff.
To put the unit into operation, please plug the mains plugs into a 230V AC socket. If the water level has reached
or exceeded the cut-in level, the pump will start to run immediately.
To stop the operation of the pump, please pull the mains plug off the socket.
The discharge quantity can be continuously adjusted using the stopcock of the outlet element. However, please
do avoid the operation of the pump with the stopcock closed, since this can cause considerable damage.
Therefore, you should stop the pump’s operation by pulling out the mains plug from the socket immediately after
closing the stopcock.
The negligible water leakage at the lateral venting bore hole - about 10 cm below the pressure port - is inherent to
the design of the device and provides for both venting at the start-up of the pump and for temporary pressure
relief when the stopcock is closed, respectively.
The electrical pumps of the T.I.P. DIO series are equipped with an integrated thermal motor protection feature. In
the case of overload, the motor will switch off independently and on again after cooling down. For possible causes
and their elimination, please refer to the “Maintenance and troubleshooting” section.
11

Chat with your T.I.P. DIO 45/13 flex manual using AI

Get instant AI answers from your T.I.P. DIO 45/13 flex manual

Ask anything about the T.I.P. DIO 45/13 flex. Answers come from this manual, with the pages they are based on.

DIO 45/13 flex Maintenance Schedule

Remind me when maintenance is due
Every 6 months
Inspect pump seals during continuous fish-pond use

When used continuously in fish ponds, check the pump seals at regular 6-month intervals.

Show in the manual (page 17)
Before each use
Visually inspect the pump, cable, and plug

Before each use, inspect the pump visually, especially the mains connection cable and plug. Do not use a damaged pump.

Show in the manual (page 13)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: gpt-5.6-terra

Ask a Question

0/1000

Do you recommend DIO 45/13 flex?

Yes No
0
User Pic

Iván Tello

10 months ago

Does the upper hose/elbow connection with the plastic hose clamp hold up, or does it come loose after a short time?

0
User Pic

Manual.ly

10 months ago

The pump itself is designed to be reliable, but the hose connection depends on correct installation and strain-free routing. Please make sure the hose is fully seated on the fitting, the clamp is positioned correctly and tightened firmly (do not overtighten), and the hose is not under pull or twist. After the first short run, quickly recheck the connection for any movement. If the plastic fitting or clamp still comes loose after proper installation, please contact our support with a photo of the part and your order details so we can help with troubleshooting or a replacement under the warranty.

M: OA-GPT-5-NAN
M: OA-GPT-5-NAN

Frequently Asked Questions

A

The pump handles clear, clean or moderately dirty water containing solids up to 2 mm. It is not suitable for saltwater, sewage, fecal-contaminated water, flammable, corrosive, explosive or otherwise hazardous liquids.

Is this answer helpful?

A

Nominal power 350 W, max flow 2,700 L/h, max pressure 1.3 bar, max delivery height 13 m, max immersion depth 5 m, max liquid temperature 35 °C, and a 10 m H05RN-F connection cable.

Is this answer helpful?

A

The integrated float switch automatically starts the pump when water reaches the cut-in level and stops it at the cut-out level. If you need to pump below the cut-out level, the float can be manually held upright but the pump must be supervised to prevent dry running.

Is this answer helpful?

A

Use a properly earthed 230 V supply protected by a residual current device (RCD/FI) with rated residual current ≤ 30 mA. If using an extension cable, choose at least 3 x 1.0 mm² rubber-sheathed (H05RN-F) cable and ensure splashproof connections.

Is this answer helpful?

A

Under normal use the pump is largely maintenance-free. Periodically check and clean inlet screens and pressure lines, counter-flush the hydraulic section if blocked, and remove the pump for cleaning or to clear the pump foot. Major repairs should be done by the manufacturer or authorized service.

Is this answer helpful?

A

First check power supply, float switch freedom, blockages in intake or pressure line, and correct immersion level. For thermal cut-out, allow cooling. If you cannot resolve the issue, contact T.I.P. service or an authorized repair center.

Is this answer helpful?

A

A two-year manufacturer warranty covers material and manufacturing defects for private end customers (conditions apply). Spare parts and accessories can be ordered via the T.I.P. website; contact [email protected] for manuals or service assistance.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • High flow: up to 2,700 L/h and 13 m max head for fast garden tasks.
  • Automatic float switch for hands-free start/stop operation.
  • Integrated thermal motor protection prevents motor damage from overload.
  • Modular riser segments and flexible outlet with shut-off valve for adaptable installation.
  • Long 10 m cable and IPX8 rating allow deep submersion and flexible placement.
VS

Disadvantages

  • Not suitable for saltwater, sewage, flammable or corrosive liquids.
  • Max solid size 2 mm — susceptible to clogging with larger debris or sand.
  • Intended for private use only; not for commercial, industrial or continuous circulation.
  • Requires RCD (≤30 mA) and proper earthing; electrical setup may need a qualified electrician.
  • Must be removed and drained in freezing conditions to avoid damage.
M: OA-GPT-5-NAN

Product Specification

Power

350W

Flow rate

713.26 gal/h

Delivery head

42.65 ft

Immersion depth

16.40 ft

Pressure

18.85 psi

Pressure connection

3/4"

Special features

without tank

Cable length

32.81 ft

Weight

9.48 lb

M: OA-GPT-54-NAN

Product Description

T.I.P. DIO 45/13 flex Electric Rain Barrel Pump

The T.I.P. DIO 45/13 flex is a compact, submersible rain-barrel pump designed for reliable domestic water reuse — emptying rain barrels, filling watering cans and powering garden watering nozzles. Built with a 350 W motor and IPX8 protection, it delivers up to 2,700 L/h and a maximum head of 13 m, making routine garden tasks quick and efficient. Its 10 m power cable and flexible outlet with shut-off valve plus modular riser segments allow adaptable installation for temporary or fixed setups.

This pump is intended for private household use only. It handles clear, slightly dirty water with solids up to 2 mm and must not be used for saltwater, wastewater, flammable, corrosive or otherwise hazardous liquids. The unit features an oil-lubricated chamber for durability, a float switch for automatic on/off control, and integrated thermal motor protection to prevent overload.

Installation is straightforward: mount the required riser segments, screw them to the pump outlet, attach the flexible outlet with the stopcock and secure the assembly with the supplied clamp. Position the pump vertically and submerged within specified immersion limits, avoid suction of sediment by keeping distance from the container bottom, and ensure the float switch can move freely. Electrical connection requires a grounded 230 V supply protected by a residual current device (RCD) ≤ 30 mA; use only suitable extension cables (3 x 1.0 mm², H05RN-F) when necessary.

Operation is user-friendly: plug into a 230 V outlet, the pump starts automatically when the water reaches the start level and stops at the shut-off level. Flow can be regulated with the outlet stopcock, but do not run the pump with the stopcock closed. The thermal motor protector cuts out on overload and restarts after cooling. Routine maintenance is minimal — periodic cleaning of inlet and pressure line and occasional counter-flushing will prevent blockages. In case of persistent faults, contact T.I.P. service.

T.I.P. provides a two-year warranty for private end customers covering material and manufacturing defects (conditions apply). Spare parts and accessories can be ordered via the manufacturer website and service support is available by phone or email.

Notes

  • Always use a 30 mA RCD and ensure proper grounding.
  • Avoid dry running and temperatures above 35 °C.
  • Remove the pump for frost protection and store dry and frost-free.
  • Replace damaged power cables only by qualified personnel.