T.I.P. DIO 45/13 flex Manual
PDF manual · 52 Pages
English

Quick check
Incorrect answer, please try again.
Chat with your T.I.P. DIO 45/13 flex manual using AI
Get instant AI answers from your T.I.P. DIO 45/13 flex manual
Ask anything about the T.I.P. DIO 45/13 flex. Answers come from this manual, with the pages they are based on.
DIO 45/13 flex Maintenance Schedule
When used continuously in fish ponds, check the pump seals at regular 6-month intervals.
Before each use, inspect the pump visually, especially the mains connection cable and plug. Do not use a damaged pump.
Free maintenance reminders
Timed to your purchase date. Always free, unsubscribe anytime.
Ask a Question
Do you recommend DIO 45/13 flex?
Yes NoFrequently Asked Questions
The pump handles clear, clean or moderately dirty water containing solids up to 2 mm. It is not suitable for saltwater, sewage, fecal-contaminated water, flammable, corrosive, explosive or otherwise hazardous liquids.
Is this answer helpful?
Nominal power 350 W, max flow 2,700 L/h, max pressure 1.3 bar, max delivery height 13 m, max immersion depth 5 m, max liquid temperature 35 °C, and a 10 m H05RN-F connection cable.
Is this answer helpful?
The integrated float switch automatically starts the pump when water reaches the cut-in level and stops it at the cut-out level. If you need to pump below the cut-out level, the float can be manually held upright but the pump must be supervised to prevent dry running.
Is this answer helpful?
Use a properly earthed 230 V supply protected by a residual current device (RCD/FI) with rated residual current ≤ 30 mA. If using an extension cable, choose at least 3 x 1.0 mm² rubber-sheathed (H05RN-F) cable and ensure splashproof connections.
Is this answer helpful?
Under normal use the pump is largely maintenance-free. Periodically check and clean inlet screens and pressure lines, counter-flush the hydraulic section if blocked, and remove the pump for cleaning or to clear the pump foot. Major repairs should be done by the manufacturer or authorized service.
Is this answer helpful?
First check power supply, float switch freedom, blockages in intake or pressure line, and correct immersion level. For thermal cut-out, allow cooling. If you cannot resolve the issue, contact T.I.P. service or an authorized repair center.
Is this answer helpful?
A two-year manufacturer warranty covers material and manufacturing defects for private end customers (conditions apply). Spare parts and accessories can be ordered via the T.I.P. website; contact [email protected] for manuals or service assistance.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- High flow: up to 2,700 L/h and 13 m max head for fast garden tasks.
- Automatic float switch for hands-free start/stop operation.
- Integrated thermal motor protection prevents motor damage from overload.
- Modular riser segments and flexible outlet with shut-off valve for adaptable installation.
- Long 10 m cable and IPX8 rating allow deep submersion and flexible placement.
Disadvantages
- Not suitable for saltwater, sewage, flammable or corrosive liquids.
- Max solid size 2 mm — susceptible to clogging with larger debris or sand.
- Intended for private use only; not for commercial, industrial or continuous circulation.
- Requires RCD (≤30 mA) and proper earthing; electrical setup may need a qualified electrician.
- Must be removed and drained in freezing conditions to avoid damage.
Product Specification
Power
350W
Flow rate
713.26 gal/h
Delivery head
42.65 ft
Immersion depth
16.40 ft
Pressure
18.85 psi
Pressure connection
3/4"
Special features
without tank
Cable length
32.81 ft
Weight
9.48 lb
Product Description
T.I.P. DIO 45/13 flex Electric Rain Barrel Pump
The T.I.P. DIO 45/13 flex is a compact, submersible rain-barrel pump designed for reliable domestic water reuse — emptying rain barrels, filling watering cans and powering garden watering nozzles. Built with a 350 W motor and IPX8 protection, it delivers up to 2,700 L/h and a maximum head of 13 m, making routine garden tasks quick and efficient. Its 10 m power cable and flexible outlet with shut-off valve plus modular riser segments allow adaptable installation for temporary or fixed setups.
This pump is intended for private household use only. It handles clear, slightly dirty water with solids up to 2 mm and must not be used for saltwater, wastewater, flammable, corrosive or otherwise hazardous liquids. The unit features an oil-lubricated chamber for durability, a float switch for automatic on/off control, and integrated thermal motor protection to prevent overload.
Installation is straightforward: mount the required riser segments, screw them to the pump outlet, attach the flexible outlet with the stopcock and secure the assembly with the supplied clamp. Position the pump vertically and submerged within specified immersion limits, avoid suction of sediment by keeping distance from the container bottom, and ensure the float switch can move freely. Electrical connection requires a grounded 230 V supply protected by a residual current device (RCD) ≤ 30 mA; use only suitable extension cables (3 x 1.0 mm², H05RN-F) when necessary.
Operation is user-friendly: plug into a 230 V outlet, the pump starts automatically when the water reaches the start level and stops at the shut-off level. Flow can be regulated with the outlet stopcock, but do not run the pump with the stopcock closed. The thermal motor protector cuts out on overload and restarts after cooling. Routine maintenance is minimal — periodic cleaning of inlet and pressure line and occasional counter-flushing will prevent blockages. In case of persistent faults, contact T.I.P. service.
T.I.P. provides a two-year warranty for private end customers covering material and manufacturing defects (conditions apply). Spare parts and accessories can be ordered via the manufacturer website and service support is available by phone or email.
Notes
- Always use a 30 mA RCD and ensure proper grounding.
- Avoid dry running and temperatures above 35 °C.
- Remove the pump for frost protection and store dry and frost-free.
- Replace damaged power cables only by qualified personnel.
Search for 67,706 Manuals online
Type-in Brand or Model
Iván Tello
10 months ago
Does the upper hose/elbow connection with the plastic hose clamp hold up, or does it come loose after a short time?
Manual.ly
10 months ago
The pump itself is designed to be reliable, but the hose connection depends on correct installation and strain-free routing. Please make sure the hose is fully seated on the fitting, the clamp is positioned correctly and tightened firmly (do not overtighten), and the hose is not under pull or twist. After the first short run, quickly recheck the connection for any movement. If the plastic fitting or clamp still comes loose after proper installation, please contact our support with a photo of the part and your order details so we can help with troubleshooting or a replacement under the warranty.