Manual.ly Logo

PowerWalker VFI 1000 AT Manual

0.0 · 0 Ratings

PDF manual · 6 Pages

English

M: gpt-5.6-terra
page

/ 6

Loading...
0e3dd4a470a5f6bcadfe4dac87b3c4437b50 page 1
1
ENGLISH
General Manual
PowerWalker Uninterruptible Power Supply
This manual contains important safety precautions, general UPS instructions and useful hints that should
be followed during installation, operation and maintenance of the UPS and batteries. Before using the
product, please also read the second manual that covers series-specific information.
I. Safety & Emergency
1. This is a product for commercial and industrial application (Class A). Installation restrictions or
additional measures may be needed to prevent potential disturbances.
2. Do not allow liquids or any foreign object to enter the UPS. No containers with liquids shall be placed
on the UPS or in close vicinity.
3. The utility power outlet shall be near the equipment and easily accessible. In the event of an
emergency, press OFF button and disconnect the power cord from the AC power supply.
4. In the event of fire in the vicinity, please use dry powder fire extinguishers.
5. Even after the unit is disconnected from the input socket, internal components are still connected to
the battery which is potentially dangerous. If any internal inspection or replacement of the battery is
required, please contact a qualified technician.
6. Please recycle all possible components. The batteries are not to be disposed in your domestic waste
container.
7. Installation and usage must be performed in accordance with the local electric regulations and safety
requirements. Please check if protected equipment or environment has any special requirements.
II. Information
1. Uninterruptible Power Supplies are designed to protect sensitive electronic equipment from power
outages and interference. It is equipped with many features that allow any attached equipment to
operate longer and with higher reliability.
2. The product is pluggable to the wall socket and if your version is delivered with batteries already
installed, it can be operated by laymen.
3. Icon Φ on the rating label stands for phase symbol.
4. This product complies with the safety and environmental regulations in EU.
III. Preparation
1. This unit is intended for installation in a controlled environment. Operating under following
conditions is prohibited:
Combustible gas, corrosive substance or heavy dust.
Extraordinarily high or low temperature.
Standing or running water or extreme humidity.
Exposed to direct sunshine or near any heating apparatus.
Serious vibrations.

Chat with your PowerWalker VFI 1000 AT manual using AI

Get instant AI answers from your PowerWalker VFI 1000 AT manual

Ask anything about the PowerWalker VFI 1000 AT. Answers come from this manual, with the pages they are based on.

VFI 1000 AT Maintenance Schedule

Remind me when maintenance is due
Monthly
Monitor battery condition

Frequently monitor the battery condition. If discharging time is less than 50% of rated value, replace batteries.

Every 2 Months
Charge battery during hot storage

In high-temperature locations during extended storage, repeat charging every two months.

Quarterly
Charge battery during storage

During extended storage in moderate climates, charge the battery for several hours every three months by plugging into power.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend VFI 1000 AT?

Yes No

Frequently Asked Questions

A

It is an online uninterruptible power supply intended to protect sensitive equipment from power outages, voltage variation, and other mains disturbances. It can support safer shutdowns or continued operation during short interruptions.

Is this answer helpful?

A

No. USB and RS-232 serial communication are alternative connection methods. Select the interface that suits the monitoring setup, but do not operate both ports simultaneously.

Is this answer helpful?

A

A minimum initial charging period of six hours is recommended. The battery charges whenever the UPS is connected to mains power, whether the UPS output is on or off.

Is this answer helpful?

A

Avoid power strips, surge protectors, and appliances that can create high demand, such as vacuum cleaners or hair dryers. Also verify that all connected loads, including startup current, stay within the UPS capacity.

Is this answer helpful?

A

Monitoring software can display UPS status, assist with scheduled battery tests, and support automatic shutdown settings. These functions help administrators track battery health and improve service continuity.

Is this answer helpful?

A

Fully charge the battery, switch the unit off, disconnect all cables, and store it in a cool, dry location. Recharge it periodically during storage and use original packaging where possible for transport protection.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • Online double-conversion design delivers regulated output for sensitive electronic equipment.
  • USB and serial communication support monitoring, battery checks, and planned shutdown workflows.
  • Battery-backed output helps systems remain active or shut down safely during mains failures.
  • The battery charges while connected to mains power, even when UPS output is switched off.
VS

Disadvantages

  • USB and RS-232 communication ports cannot operate simultaneously.
  • Battery servicing should be performed only by qualified personnel using proper safety procedures.
  • High-startup-current devices and household appliances may overload the UPS.
  • Best battery life requires a controlled environment and regular condition monitoring.
M: gpt-5.6-terra

Product Specification

Type

Tower

Classification

VFI (Online)

Apparent Power

1,000 VA

Active Power

900 W

Voltage

208 V, 220 V, 230 V, 240 V

Input

C14

Outputs

3 x Schuko

Interfaces

USB, serial

Data Line Protection

RJ-11, RJ-45

Charging Time

4 h (90%)

Weight

31.97 lb

Dimensions (W x H x D)

5.51 x 7.52 x 12.87 in

Features

LCD, HID support

M: gpt-5.6-terra

Product Description

BlueWalker PowerWalker VFI 1000 AT, USB/serial - Read, Download & Print Free

The BlueWalker PowerWalker VFI 1000 AT is an uninterruptible power supply designed to help keep critical electronic equipment protected when utility power becomes unstable or unavailable. As an online UPS, it uses double-conversion technology to deliver a consistently regulated output, making it a strong fit for workstations, network hardware, point-of-sale systems, and other sensitive business equipment.

Stable Power for Sensitive Loads

Power disturbances can take many forms, including outages, voltage drops, surges, and fluctuating mains supply. This UPS is built to isolate connected equipment from those issues and maintain dependable power quality. Its battery-backed operation provides valuable time to save work, shut down systems correctly, or continue essential operations during a power interruption.

The unit should be connected to an easily accessible grounded outlet and operated in a clean, dry, controlled indoor environment. Keep ventilation openings clear to reduce overheating risk, and ensure that connected devices remain within the UPS rated capacity. For practical headroom during changing power demand, planned loads should remain below 80% of the rated capacity.

USB and Serial Monitoring

The BlueWalker PowerWalker VFI 1000 AT offers USB and serial communication options for connection to a compatible computer or monitoring environment. Monitoring software can support status checks, scheduled battery testing, and automated shutdown planning, helping administrators maintain service availability. USB and RS-232 connections are alternatives and should not be used at the same time.

Battery management is central to reliable UPS ownership. The battery charges while the UPS is connected to mains power, whether the output is switched on or off. A minimum six-hour initial recharge is recommended to help achieve full battery capacity. Long-term performance is best supported by an ambient temperature near 25 C and regular battery-condition checks.

Installation and Care Notes

Use approved power cables and avoid connecting power strips, surge protectors, or high-demand household appliances to the UPS output. Equipment with substantial startup current must also stay within the unit's capacity. The UPS can provide output from its internal battery source, so its outlets may remain energized even when it is disconnected from building wiring.

For maintenance, keep the surrounding area dust-free and clean external surfaces only with a dry, soft cloth after disconnecting power. Battery replacement requires trained personnel, insulated tools, and batteries matching the original specifications. Used batteries must be recycled according to local requirements.

Note: In an emergency, switch the UPS off and disconnect it from mains power. If smoke is observed, disconnect power and contact qualified service support.