Manual.ly Logo

PeakTech 40xx Series Manual

0.0 · 0 Ratings

PDF manual · 68 Pages

English

M: gpt-5.6-terra
page

/ 68

Loading...
e642acc9e485cbad373a8a6d1d1c5da27389 page 6
1.General Safety Requirements
2
General Safety Requirements
Before any operations, please read the following safety precautions to avoid any
possible bodily injury and prevent this product or any other products connected from
damage. In order to avoid any contingent danger, this product is only used within the
range specified.
Check AC power input setting according to the standards in your own country (see
page 13, AC Power Input Setting).
Use Proper Power Cord. Use only the power cord supplied with the product and
certified to use in your country.
Product Grounded. This instrument is grounded through the power cord grounding
conductor. To avoid electric shock, the grounding conductor must be grounded. The
product must be grounded properly before any connection with its input or output
terminal.
Limit operation to the specified measurement category, voltage, or amperage
ratings.
Check all Terminal Ratings. To avoid instrument damage and the risk of electric
shock, check all the Measurement Limits and markers of this product. Refer to the
user's manual for the Measurement Limits before connecting to the instrument. Do
not exceed any of the Measurement Limits defined in the following section.
Do not operate without covers. Do not operate the instrument with covers or panels
removed.
Use Proper Fuse. Use only the specified type and rating fuse for this instrument.
Avoid exposed circuit. Do not touch exposed junctions and components when the
instrument is powered.
Do not operate if in any doubt. If you suspect damage occurs to the instrument,
have it inspected by qualified service personnel before further operations.
Use your instrument in a well-ventilated area. Inadequate ventilation may cause
increasing of temperature or damages to the device. Please keep well ventilated and
inspect the intake regularly.
Do not operate in wet conditions. In order to avoid short circuiting to the interior of
the device or electric shock, please do not operate in a humid environment.
Do not operate in an explosive atmosphere.
Keep product surfaces clean and dry.
Only the qualified technicians can implement the maintenance.

Chat with your PeakTech 40xx Series manual using AI

Get instant AI answers from your PeakTech 40xx Series manual

Ask anything about the PeakTech 40xx Series. Answers come from this manual, with the pages they are based on.

40xx Series Maintenance Schedule

Remind me when maintenance is due
Yearly
Calibrate the instrument

The manual recommends calibrating the unit again after 1 year to ensure accuracy.

Show in the manual (page 68)
As needed
Clean the instrument exterior

Disconnect power and leads. Use a wet soft cloth not dripping water. Do not use corrosive agents or sprays.

Show in the manual (page 66)
Regularly
Inspect ventilation intake

Keep the area well-ventilated and inspect the intake regularly to prevent overheating or damage.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend 40xx Series?

Yes No

Frequently Asked Questions

A

The range includes the PeakTech P 4094, P 4095, and P 4096 graphical bench multimeters. Their core functions are similar, but resolution, ranges, frequency capability, display capacity, and accuracy differ by model.

Is this answer helpful?

A

It measures DC and AC voltage, DC and AC current, two-wire and four-wire resistance, continuity, diodes, capacitance, frequency, period, and temperature. Temperature support includes several thermocouple types plus PT100 and PT385 RTD sensors.

Is this answer helpful?

A

Four-wire resistance measurement separates the current-carrying and sensing paths. This reduces the influence of test lead and contact resistance, making it particularly useful when measuring resistances below 100 kOhm.

Is this answer helpful?

A

Yes. Manual saving stores up to 1,000 readings. Automatic logging can record to internal memory or a USB device, and results can be exported in CSV format for analysis on a computer.

Is this answer helpful?

A

The instruments provide USB Type-B, RS-232, and LAN connections. They also support SCPI communication, making them suitable for remote control, data collection, and automated test arrangements.

Is this answer helpful?

A

The HI and LO measurement inputs are rated up to 1000 V DC or 750 V AC for measurement. The safety category rating is 1000 V CAT I and 600 V CAT II. Maximum limits must never be exceeded.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • Comprehensive bench measurement set includes voltage, current, resistance, continuity, diode, capacitance, frequency, period, and temperature.
  • True RMS AC measurement, graphical display modes, dual readings, statistics, limits, REL, and dB/dBm support detailed analysis.
  • Four-wire resistance measurement helps minimize lead and contact resistance errors in low-resistance applications.
  • USB, RS-232, LAN, SCPI, external trigger, and CSV export support automated and PC-connected workflows.
  • Automatic logging supports up to 1 million internal points or 100 million points on external USB storage.
VS

Disadvantages

  • The three models have different resolution, bandwidth, frequency range, and accuracy specifications, so selection requires careful comparison.
  • AC True RMS readings are AC-coupled; AC plus DC RMS requires combining separate DC and AC measurement results.
  • High-current operation above 7 A is limited by a recommended 30-seconds-on, 30-seconds-off duty cycle.
  • Automatic range changes can create temporarily invalid logged readings during relay switching.
  • The instruments are intended for indoor use and are not designed for high-energy circuits.
M: gpt-5.6-terra

Product Specification

Package contents

Test leads, power cord

M: gpt-5.6-terra

Product Description

PeakTech P 40xx TrueRMS Digital-Multimeter Manual

The PeakTech P 40xx TrueRMS Digital-Multimeter range brings bench-grade measurement capability to electronics labs, service departments, development benches, and educational environments. Covering the P 4094, P 4095, and P 4096 models, these graphic tabletop multimeters combine a large LCD interface with practical controls for repeatable everyday testing. The PeakTech P 40xx TrueRMS Digital-Multimeter Manual keyword is especially relevant for users comparing functions, connections, safety limits, and model-specific performance.

Broad measurement capability

These instruments measure DC and AC voltage, DC and AC current, resistance, continuity, diode voltage, capacitance, frequency, period, and temperature. True RMS AC measurement supports more dependable readings on non-sinusoidal signals within the specified bandwidth. The P 4095 and P 4096 offer AC voltage bandwidth up to 100 kHz and AC current bandwidth up to 10 kHz, while the P 4096 reaches frequency measurements up to 1 MHz.

Four-wire resistance capability is a key advantage for low-resistance work. By separating current and sense connections, it helps reduce errors caused by test leads and contact resistance. Temperature measurement supports multiple thermocouple types, including B, E, J, K, N, R, S, and T, along with PT100 and PT385 RTD sensors.

Clear data on screen and beyond

A configurable graphical display can present values as large digits, a bar meter, trend graph, or histogram. Dual-display operation allows compatible primary and secondary measurements to be viewed together, such as voltage with frequency. Mathematical tools include relative readings, statistics, pass/fail limits, and dB/dBm calculations for voltage-based work.

For data capture, manual storage holds up to 1,000 readings. Automatic recording supports up to 1 million internal points or up to 100 million points on external USB storage, depending on configuration. Saved results can be exported as CSV data for review in spreadsheet or analysis software.

Connectivity and controlled measurement workflows

USB, RS-232, and LAN interfaces make the P 40xx range suitable for PC-connected measurement setups. SCPI support assists integration with automated test systems. Auto, single, and external trigger modes support controlled acquisitions, while the rear auxiliary output can signal measurement completion or pass/fail status.

Notes

  • Choose the correct mains voltage setting and matching fuse before powering the instrument.
  • Observe the 1000 V CAT I and 600 V CAT II input safety ratings.
  • For best specified accuracy, allow a 30-minute warm-up period and use appropriate measurement speed settings.
  • Continuous currents above 7 A require a 30-seconds-on, 30-seconds-off duty cycle.
M: gpt-5.6-terra

© Copyright 2026 Manual.ly