4f074213f212c02d8ed9e021b92d601c9453 page 15
* Use caution when working with voltages above 35V DC or 25V
AC. These Voltages pose shock hazard.
* Fetch out the battery when the meter will not be used for long
period.
* Periodically wipe the cabinet with a damp cloth and mid
detergent. Do not use abrasives or solvents.
* The meter is suitable for indoor use only
* Do not operate the meter before the cabinet has been closed
and screwed safely as terminal can carry voltage.
* Do not store the meter in a place of explosive, inflammable
substances.
* Do not modify the equipment in any way
* Do not place the equipment face-down on any table or work
bench to prevent damaging the controls at the front.
* Opening the equipment and service- and repair work must
only be performed by qualified service personnel
* Measuring instruments don’t belong to children hands.
Cleaning the cabinet
Clean only with a damp, soft cloth and a commercially available
mild household cleanser. Ensure that no water gets inside the
equipment to prevent possible shorts and damage to the
equipment.
1.1. Safety Rules
Warning
This tester has been designed with your safety in mind. However,
no design can completely protect against incorrect use. Electrical
circuits can be dangerous and/or lethal when lack of caution or
poor safety practices are used.
Read the manual
Read this instruction manual carefully and completely. Voltages
and currents within the capability of this test equipment can be
hazardous. Follow the instructions in this manual for every
measurement. Read and understand the general instructions
before attempting to use this tester. Do not exceed the limits of
the tester.
-20-

Chat with your PeakTech 3385 manual using AI

Get instant AI answers from your PeakTech 3385 manual

Ask anything about the PeakTech 3385. Answers come from this manual, with the pages they are based on.

3385 Maintenance Schedule

Remind me when maintenance is due
Yearly
Recalibrate the unit

The manufacturer recommends repeating the factory calibration after one year of use.

Show in the manual (page 34)
Periodically
Clean the cabinet

Wipe the cabinet with a damp, soft cloth and mild household cleanser. Ensure no water enters the device to prevent shorts.

Show in the manual (page 21)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend 3385?

Yes No

Frequently Asked Questions

A

The multimeter requires three standard 1.5V AAA batteries. Ensure correct polarity when installing them into the rear compartment to avoid damage.

Is this answer helpful?

A

No. Always turn off power and discharge capacitors before measuring resistance. Applying voltage while in resistance mode can damage the internal fuse and movement.

Is this answer helpful?

A

The device is rated for Overvoltage Category III with a maximum of 600V. Do not exceed this limit to prevent injury or equipment failure.

Is this answer helpful?

A

Use the AC voltage scale corresponding to your range. Add 12, 20, or 32dB if measuring in 60V, 150V, or 600V ranges respectively for the correct value.

Is this answer helpful?

A

Use 500mA or 10A fast blow fuses rated at 690V with dimensions 10.3mm by 38mm. Always disconnect leads before accessing the rear case for replacement.

Is this answer helpful?

A

It is designed for indoor applications only. Exposure to moisture or extreme temperatures can degrade performance and void safety ratings.

Is this answer helpful?

A

Factory calibration is valid for one year under normal conditions. Annual recalibration is recommended to maintain the stated accuracy specifications.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Analog needle provides real-time trend observation unlike digital numbers
  • Comprehensive measurement ranges cover voltage current and resistance
  • CAT III safety rating protects against high energy electrical transients
  • Clear scale markings facilitate quick reading in various lighting
  • Easy maintenance with accessible battery and fuse compartments
VS

Disadvantages

  • Parallax error can occur if eye is not aligned with needle
  • Manual zero adjustment is required before each measurement session
  • Limited frequency response restricts use above 400 Hz applications
  • Bulky design takes up more space than compact digital tools
  • Lower resolution readings compared to modern digital multimeter devices
M: QW-35-FL

Product Specification

Measurement Range

max. 10A, max. 600V, max. 2MΩ

Package Contents

Carry Case, Test Leads

M: QW-35-FL

Product Description

Comprehensive Guide to the PeakTech 3385 Analog Multimeter Manual

Choosing the right diagnostic equipment is essential for ensuring safety and accuracy in electrical work. The PeakTech 3385 Analog Multimeter offers a robust platform for measuring complex circuits effectively. It delivers a traditional analog display that allows users to observe signal trends over time. This instrument complies with Low Voltage and Electromagnetic Compatibility directives for European Union standards.

Measurement Versatility

Users can measure DC and AC voltage, current, resistance, and decibels with this device. The analog dial provides immediate feedback which is helpful for troubleshooting unstable connections. The resistance ranges cover from two ohms up to two mega ohms using multipliers. Input jacks are labeled clearly to prevent incorrect connections during operation. Mechanical zero adjustment ensures the needle starts at the correct position for reading.

Safety Protocols

Safety remains key with the Overvoltage Category III 600V design rating. Fused inputs on the high current ranges protect the internal mechanism from damage. Test leads must be rated for 4mm safety when connecting to live power sources. Do not operate equipment near strong magnetic fields or wet surfaces. Keep the case closed during use to prevent accidental contact with voltage carrying terminals.

Maintenance Requirements

The unit requires three AAA batteries for power operation. Ensure new cells are installed with correct polarity before use. Store the device in a dry location away from direct sunlight. Remove batteries if not using the unit for extended periods. Calibrate the instrument annually to guarantee the stated percent accuracy from full scale. Rotate the switch occasionally if not used to clean contacts.

Dimensions and Power

This meter weighs 380 grams and measures 115 by 175 by 45 mm. These dimensions allow it to fit into standard tool cases easily. Operating temperatures should stay between zero and forty degrees Celsius. Avoid exposing the device to extreme humidity or shocks. The 50 Hz to 400 Hz frequency response suits standard power applications.

Practical Applications

Applying the PeakTech 3385 Analog Multimeter Manual advice ensures you use the tools correctly. Technicians often find the tactile dial selection faster than digital menu systems. Checking fuses regularly maintains the safety integrity of the input protection circuits. Always remove test leads before changing measurement modes on live circuits. This practice prevents burning out the internal meter movement during operation.

Technical Notes

The built-in buzzer sounds for continuity checks below fifty ohms resistance. Decibel measurements utilize specific scale multipliers depending on the voltage range selected. Adding twelve, twenty, or thirty-two decibels corrects the reading on higher scales. These calculations allow for accurate signal level monitoring in audio or power systems. Replacement involves opening the rear case and swapping fast blow fuses. Ensure the new fuse matches the original voltage and current ratings exactly. Using incorrect fuses compromises safety protection during electrical faults. This maintenance step should be performed only after disconnecting power.

M: QW-35-FL

© Copyright 2026 Manual.ly