Manual.ly Logo

PeakTech 3385 Manual

0.0 · 0 Ratings

PDF manual · 36 Pages

English

M: QW-35-FL
page

/ 36

Loading...
4f074213f212c02d8ed9e021b92d601c9453 page 13
1. Safety Precautions
This product complies with the requirements of the following
directives of the European Union for CE conformity: 2014/30/EU
(electromagnetic compatibility), 2014/35/EU (low voltage),
2011/65/EU (RoHS).
Overvoltage category III 600V; pollution degree 2.
CAT I: For signal level, telecommunication, electronic with
small transient over voltage
CAT II: For local level, appliances, main wall outlets, portable
equipment
CAT III: Supplied from a cable under earth; fixed installed
switches, automatic cut-off or main plugs
CAT IV: Units and installations, which are supplied overhead
lines, which are stand in a risk of persuade of a
lightning, i.e. main-switches on current input,
overvoltage-diverter, current use counter.
To ensure safe operation of the equipment and eliminate the
danger of serious injury due to short-circuits (arcing), the following
safety precautions must be observed.
Damages resulting from failure to observe these safety
precautions are exempt from any legal claims whatever.
* Do not use this instrument for high-energy industrial
installation measurement.
* Do not operate the equipment near strong magnetic fields
(motors, transformers etc.).
* Do not place the equipment on damp or wet surfaces.
* Do not exceed the maximum permissible input ratings
(danger of serious injury and/or destruction of the equipment).
* The meter is designed to withstand the stated max voltages.
If it is not possible to exclude without that impulses, transients,
disturbance or for other reasons, these voltages are
exceeded a suitable presale (10:1) must be used.
-18-

Chat with your PeakTech 3385 manual using AI

Get instant AI answers from your PeakTech 3385 manual

Ask anything about the PeakTech 3385. Answers come from this manual, with the pages they are based on.

3385 Maintenance Schedule

Remind me when maintenance is due
Yearly
Recalibrate the unit

The manufacturer recommends repeating the factory calibration after one year of use.

Show in the manual (page 34)
Periodically
Clean the cabinet

Wipe the cabinet with a damp, soft cloth and mild household cleanser. Ensure no water enters the device to prevent shorts.

Show in the manual (page 21)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend 3385?

Yes No

Frequently Asked Questions

A

The multimeter requires three standard 1.5V AAA batteries. Ensure correct polarity when installing them into the rear compartment to avoid damage.

Is this answer helpful?

A

No. Always turn off power and discharge capacitors before measuring resistance. Applying voltage while in resistance mode can damage the internal fuse and movement.

Is this answer helpful?

A

The device is rated for Overvoltage Category III with a maximum of 600V. Do not exceed this limit to prevent injury or equipment failure.

Is this answer helpful?

A

Use the AC voltage scale corresponding to your range. Add 12, 20, or 32dB if measuring in 60V, 150V, or 600V ranges respectively for the correct value.

Is this answer helpful?

A

Use 500mA or 10A fast blow fuses rated at 690V with dimensions 10.3mm by 38mm. Always disconnect leads before accessing the rear case for replacement.

Is this answer helpful?

A

It is designed for indoor applications only. Exposure to moisture or extreme temperatures can degrade performance and void safety ratings.

Is this answer helpful?

A

Factory calibration is valid for one year under normal conditions. Annual recalibration is recommended to maintain the stated accuracy specifications.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Analog needle provides real-time trend observation unlike digital numbers
  • Comprehensive measurement ranges cover voltage current and resistance
  • CAT III safety rating protects against high energy electrical transients
  • Clear scale markings facilitate quick reading in various lighting
  • Easy maintenance with accessible battery and fuse compartments
VS

Disadvantages

  • Parallax error can occur if eye is not aligned with needle
  • Manual zero adjustment is required before each measurement session
  • Limited frequency response restricts use above 400 Hz applications
  • Bulky design takes up more space than compact digital tools
  • Lower resolution readings compared to modern digital multimeter devices
M: QW-35-FL

Product Specification

Measurement Range

max. 10A, max. 600V, max. 2MΩ

Package Contents

Carry Case, Test Leads

M: QW-35-FL

Product Description

Comprehensive Guide to the PeakTech 3385 Analog Multimeter Manual

Choosing the right diagnostic equipment is essential for ensuring safety and accuracy in electrical work. The PeakTech 3385 Analog Multimeter offers a robust platform for measuring complex circuits effectively. It delivers a traditional analog display that allows users to observe signal trends over time. This instrument complies with Low Voltage and Electromagnetic Compatibility directives for European Union standards.

Measurement Versatility

Users can measure DC and AC voltage, current, resistance, and decibels with this device. The analog dial provides immediate feedback which is helpful for troubleshooting unstable connections. The resistance ranges cover from two ohms up to two mega ohms using multipliers. Input jacks are labeled clearly to prevent incorrect connections during operation. Mechanical zero adjustment ensures the needle starts at the correct position for reading.

Safety Protocols

Safety remains key with the Overvoltage Category III 600V design rating. Fused inputs on the high current ranges protect the internal mechanism from damage. Test leads must be rated for 4mm safety when connecting to live power sources. Do not operate equipment near strong magnetic fields or wet surfaces. Keep the case closed during use to prevent accidental contact with voltage carrying terminals.

Maintenance Requirements

The unit requires three AAA batteries for power operation. Ensure new cells are installed with correct polarity before use. Store the device in a dry location away from direct sunlight. Remove batteries if not using the unit for extended periods. Calibrate the instrument annually to guarantee the stated percent accuracy from full scale. Rotate the switch occasionally if not used to clean contacts.

Dimensions and Power

This meter weighs 380 grams and measures 115 by 175 by 45 mm. These dimensions allow it to fit into standard tool cases easily. Operating temperatures should stay between zero and forty degrees Celsius. Avoid exposing the device to extreme humidity or shocks. The 50 Hz to 400 Hz frequency response suits standard power applications.

Practical Applications

Applying the PeakTech 3385 Analog Multimeter Manual advice ensures you use the tools correctly. Technicians often find the tactile dial selection faster than digital menu systems. Checking fuses regularly maintains the safety integrity of the input protection circuits. Always remove test leads before changing measurement modes on live circuits. This practice prevents burning out the internal meter movement during operation.

Technical Notes

The built-in buzzer sounds for continuity checks below fifty ohms resistance. Decibel measurements utilize specific scale multipliers depending on the voltage range selected. Adding twelve, twenty, or thirty-two decibels corrects the reading on higher scales. These calculations allow for accurate signal level monitoring in audio or power systems. Replacement involves opening the rear case and swapping fast blow fuses. Ensure the new fuse matches the original voltage and current ratings exactly. Using incorrect fuses compromises safety protection during electrical faults. This maintenance step should be performed only after disconnecting power.

M: QW-35-FL

© Copyright 2026 Manual.ly