1. Safety Precautions
This product complies with the requirements of the following European
Community directives: 2014/30/EU (Electromagnetic Compatibility) and
2014/35/EU (Low Voltage) as amended by 2014/32/EU (CE-Marking).
Overvoltage CAT III 600V, Pollution degree 2.
CAT I: For signal level, telecommunication, electronic with small
transient over voltage
CAT II: For local level, appliances, main wall outlets, portable
equipment
CAT III: Supplied from a cable under earth; fixed installed switches,
automatic cut-off or main plugs
CAT IV: Units and installations, which are supplied overhead lines,
which are stand in a risk of persuade of a lightning, i.e. main-
switches on current input, overvoltage-diverter, current use
counter.
To ensure safe operation of the equipment and eliminate the danger of
serious injury due to short-circuits (arcing), the following safety
precautions must be observed.
Damages resulting from failure to observe these safety precautions are
exempt from any legal claims whatever.
* Do not exceed the maximum permissible input ratings (danger of
serious injury and/or destruction of the equipment).
* The meter is designed to withstand the stated max voltages. If it is not
possible to exclude without that impulses, transients, disturbance or
for other reasons, these voltages are exceeded a suitable prescale
(10:1) must be used.
* Do not operate the meter before the cabinet has been closed and
screwed safely as terminal can carry voltage.
* Replace a defective fuse only with a fuse of the original rating. Never
short-circuit fuse or fuse holding.
* Disconnect test leads or probe from the measuring circuit before
switching modes or functions.

Chat with your PeakTech 3335 manual using AI

Get instant AI answers from your PeakTech 3335 manual

Ask anything about the PeakTech 3335. Answers come from this manual, with the pages they are based on.

3335 Maintenance Schedule

As needed
Replace the battery when indicator appears

Replace the 9V battery as soon as the 'BAT' symbol lights up to ensure accurate readings and prevent damage from leakage.

Show in the manual (page 45)
Periodically
Clean the cabinet with a damp cloth

Wipe the device with a damp, lint-free cloth and mild detergent. Do not use abrasives or solvents, and keep liquid out of the interior.

Show in the manual (page 28)
After inactivity
Remove battery during long storage

If the meter will not be used for more than a week, remove the battery to prevent potential chemical leaks and damage.

Show in the manual (page 45)
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend 3335?

Yes No

Frequently Asked Questions

A

Turn off power and disconnect leads. Remove screws from the back cover. Open the compartment. Remove the old 9 volt battery and insert a new one. Close the cover and secure with screws. Do not operate with the cover open.

Is this answer helpful?

A

The device complies with CAT III 600V ratings and Pollution Degree 2 standards. This ensures protection against high voltage transients and meets EU directives for electromagnetic compatibility and low voltage equipment safety.

Is this answer helpful?

A

No, you must connect the meter in series with the circuit to measure current properly. Connecting it directly across a voltage source in a parallel configuration can damage the meter or blow the internal fuse.

Is this answer helpful?

A

Wipe the casing with a damp soft cloth. Use mild cleaning agents only. Do not use abrasive cleaners. Ensure no liquid enters the internal components or enters the ports to prevent short circuits and damage.

Is this answer helpful?

A

Overload protection safeguards the internal circuitry from accidental spikes above limits. It includes fuses on current inputs and voltage ranges to prevent severe damage to the internal electronics during misuse.

Is this answer helpful?

A

Yes, the device features automatic power off after fifteen minutes of inactivity. This conserves battery life. A manual on-off switch allows users to start and stop operation as needed.

Is this answer helpful?

A

Set the function selector to the diode test mode. Connect the red probe to the anode and black to the cathode. The display will show the forward voltage drop. Reversing the polarity should show an overrange indication.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Robust housing suitable for daily service technician tasks and workshops.
  • Clear 3 ½ digit LCD display with backlight for readability in low light environments.
  • Comprehensive safety protections including CAT III 600V ratings for high voltage transients.
  • Automatic power off feature conserves battery life after fifteen minutes of idling.
  • Includes data hold function for freezing readings for easier transcription later.
VS

Disadvantages

  • Max resolution limited to 3 ½ digits compared to higher digit professional models.
  • Requires opening casing with screws for battery or fuse replacement by technician.
  • Voltage measurement limited to 600V max, not suitable for industrial high voltage applications.
  • Temperature accuracy relies on external Type-K thermocouple sensor included in kit.
  • Must avoid operating near strong magnetic fields to prevent measurement errors.
M: QW-35-FL

Product Specification

Measurement range

Max. 10A, Max. 600V, Max. 20MΩ

Package contents

Case, Test leads

M: QW-35-FL

Product Description

Overview

The PeakTech 3335 Digital Multimeter stands as a rugged solution for technicians requiring reliable measurements. Designed for the service everyday, this unit offers robust housing that withstands daily use. It features a clear 3 ½ digit LCD display for readability in low light. Users appreciate the data hold function, allowing them to freeze readings for transcription. The device complies with strict safety standards including CAT III 600V ratings, ensuring protection against high voltage transients.

Features

Accurate measurements across multiple domains make this tool indispensable. It handles DC and AC voltage, current up to 10 amps, resistance, frequency, and capacitance. Temperature readings are possible with the included thermocouple. Safety is paramount, so all users must understand the PeakTech 3335 Digital Multimeter Manual guidelines before starting work. Incorrect usage can damage equipment or cause injury. The multimeter includes an audible beeper for continuity checks. Automatic power off conserves battery life after fifteen minutes. Overload protection safeguards the internal circuitry from accidental spikes.

Maintenance

Maintenance involves standard procedures to keep performance optimal. Replace the 9 volt battery when the low indicator appears. Keep the unit dry and avoid extreme temperatures during storage. Clean the casing with a soft cloth. Do not open the device unless you are a qualified technician. This ensures the warranty remains valid. The compact size allows for easy transport between job sites. Whether working on appliances or electronics, this meter delivers consistent results. Always check test leads for damage.

Important Note

To ensure efficiency, always start on the highest range if values are unknown. The function selector switch makes changing modes simple. Each input jack serves a specific purpose, such as the common terminal for black probes. Current measurement requires breaking the circuit to insert the meter in series. Resistance measurements are only valid on de-energized components. Frequency limits peak at 20 kHz for accurate signal analysis. The device comes with a stand for hands free operation. Warranty covers factory calibration defects.