2795 Maintenance Schedule
Re-calibration is recommended after one year of operation to maintain accuracy.
Wipe the cabinet regularly with a damp cloth and mild detergent. Do not use abrasives or solvents.
Replace the 9V battery as soon as the BAT symbol appears on the display to ensure accurate measurements.
Free maintenance reminders
Timed to your purchase date. Always free, unsubscribe anytime.
Ask a Question
Do you recommend 2795?
Yes NoFrequently Asked Questions
Yes, it measures surface speed in meters per minute, inches per minute, feet per minute, and yards per minute using the contact wheel.
Is this answer helpful?
It stores up to 10 individual measurement values including maximum, minimum, and average data points for analysis.
Is this answer helpful?
Yes, it uses a standard nine-volt battery which is easy to replace when the low battery icon appears on the screen.
Is this answer helpful?
The photo mode reaches 199,999 RPM while the contact mode operates between 2.0 and 19,999 RPM depending on the attachment used.
Is this answer helpful?
No, it is a Class 2 laser. Never point it at people or animals or look directly into the beam to prevent eye injury.
Is this answer helpful?
No, this unit is designed for indoor applications only and should be kept away from moisture and direct sunlight.
Is this answer helpful?
Use only a damp, soft cloth with mild soap. Do not use solvents or let liquid enter the device casing.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- High accuracy with resolution up to 0.05% plus one digit for critical industrial applications.
- Large LCD display with backlight ensures easy reading in low light or shadowed workshop conditions.
- Non-contact laser measurement allows safe speed checks on moving parts without physical interference.
- Built-in memory stores ten datasets including max, min, and average values for later review.
- Wide RPM range covers both high-speed motors and low-speed machinery operations accurately.
Disadvantages
- Laser Class 2 requires strict eye safety protocols preventing use near gas explosions or reflective surfaces.
- Indoor use restriction limits applicability in outdoor environments subject to water or direct sunlight.
- Only accepts a standard nine-volt battery which may need frequent replacement depending on usage frequency.
- Contact measurement requires specific adapters included to ensure readings are not falsified by surface textures.
- No USB connectivity limits data transfer to manual recording from the internal memory storage only.
Product Description
Exploring the PeakTech 2795 Tachometer
The PeakTech 2795 Tachometer stands as a robust solution for industrial and maintenance professionals requiring precise speed measurements in demanding environments. This versatile instrument allows users to perform both contact and non-contact rotation measurements effortlessly. Equipped with an integrated laser pointer, aiming becomes faster and more accurate, ensuring you hit the target spot on rotating machinery without guessing. Its design supports rapid setup for immediate results in the field. The digital LCD screen features a high-visibility backlight, making it readable even in dim workshop environments where shadow coverage is common. This PeakTech 2795 Tachometer is designed for longevity.
Performance is a key focus for this device. It offers a wide measuring range extending up to 199,999 RPM for photo mode and 19,999 RPM for contact mode. Whether you are monitoring motors, fans, or shafts, the resolution adjusts automatically for clarity. It also handles surface speed measurements in meters per minute or imperial units. The device stores up to ten individual datasets for review later. Each entry captures maximum, minimum, and average values, aiding in trend analysis and compliance checks without needing to write anything down during operation. You can recall these values instantly by pressing the memory button to compare current performance against past records.
Battery life is manageable with a standard nine-volt cell, indicated clearly by an on-screen icon when low. Safety cannot be overlooked. The unit includes a Class 2 laser which requires careful handling to avoid eye damage. It is strictly for indoor application and protects against electromagnetic interference to ensure stable readings during sensitive tests. The casing is durable but should be kept away from vibration or moisture to prevent internal damage. This tool simplifies complex diagnostics into simple button presses. It comes with a carrying case, adhesive tape, and adapters for different measurement needs. Maintenance is straightforward with regular cleaning using damp cloths. For professionals valuing speed and accuracy, this PeakTech model reduces downtime by providing immediate feedback on operational speeds across various mechanical setups. It includes adapters for specific tasks.
Regular calibration is recommended after three years to maintain factory specifications. Ensure you replace batteries immediately if the symbol appears to prevent incorrect data. Do not use near explosive gases due to the laser spark risk. It weighs just 160 grams, ensuring portability during field inspections without adding weight to your belt pack. This comprehensive package makes it an essential addition to any technical toolkit for machinery monitoring.