Manual.ly Logo

PeakTech 1240 Manual

0.0 · 0 Ratings

PDF manual · 183 Pages

English

M: QW-35-FL
page

/ 183

Loading...
0bf50ff224d38bb6670ad919237526424a8c page 5
-4-
11.5 Setting of the Band Limit (only P 1245/1255/1260) ·························································· 116
12. Application of the math function ······························································ 116
13. Using the FFT function ··········································································· 118
13.1 Selecting the FFT Window ························································································· 119
13.2 Notes for using FFT ·································································································· 121
13.3 Nyquist frequency ···································································································· 122
14. Application of the vertical position and volts/div knobs ······························ 122
15. How to set the horizontal system ····························································· 123
16. Main time base ······················································································ 124
17. Set window ··························································································· 124
18. Window expansion ················································································· 125
19. How to set the trigger system ·································································· 125
19.1 Trigger control ········································································································· 126
19.2 How to operate the function menues ············································································ 133
20. How to implement the sampling setup ······················································ 134
21. How to set the display system ································································· 136
22. Persist ·································································································· 137
23. XY format ······························································································ 138
24. Cymometer ··························································································· 139
25. VGA output ··························································································· 139
26. How to save and recall a waveform ·························································· 139
27. Save and recall the waveform ·································································· 141
27.1 How to record/playback waveforms ············································································· 142
27.2 How to implement the auxiliary system function setting ···················································· 145
28. How to measure automatically ································································· 155
29. Measurements ······················································································· 156
30. The automatic measurement of the voltage parameters ······························ 157
30.1 The automatic measurement of the time parameters ······················································· 158
31. Measurements with the cursor ································································ 158
32. The cursor measurement with the FFT model ············································ 161

Chat with your PeakTech 1240 manual using AI

Get instant AI answers from your PeakTech 1240 manual

Ask anything about the PeakTech 1240. Answers come from this manual, with the pages they are based on.

1240 Maintenance Schedule

Remind me when maintenance is due
Yearly
Perform calibration

One year is recommended for the calibration interval period to ensure measurement accuracy.

Show in the manual (page 179)
Regularly
Clean cabinet and probe

Wipe dust with a soft cloth. Clean with a damp, soft cloth and mild detergent after disconnecting power. Ensure dry before use.

Show in the manual (page 181)
As needed
Run auto-calibration

Execute self-calibration if ambient temperature varies by more than 5°C or periodically to maintain optimal state.

Show in the manual (page 19)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend 1240?

Yes No

Frequently Asked Questions

A

The PeakTech 1240 Digital Oscilloscope supports a maximum sampling rate of up to 500 MSa/s, allowing for precise capture of dynamic signals.

Is this answer helpful?

A

Yes, the device includes an integrated Fast Fourier Transform (FFT) function that converts time-domain signals into frequency spectra for detailed analysis.

Is this answer helpful?

A

The oscilloscope features two input channels, CH1 and CH2, enabling simultaneous observation and comparison of two different signals.

Is this answer helpful?

A

Absolutely. The device is equipped with a USB port for connecting to computers, facilitating data transfer and potential remote control options.

Is this answer helpful?

A

The Autoset button automatically configures the vertical scale, horizontal time base, and trigger level to display a stable waveform quickly.

Is this answer helpful?

A

Yes, the oscilloscope has a VGA output port that allows connection to external monitors or projectors for larger viewing areas.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • High resolution 8-inch TFT display for clear visualization
  • Sampling rates up to 500 MSa/s for accurate fast signal capture
  • Integrated FFT function for frequency domain analysis
  • Multiple trigger modes including Edge, Video, and Pulse
  • USB and LAN connectivity for easy data transfer and networking
VS

Disadvantages

  • Bandwidth limitation on lower models restricts high-frequency use
  • No internal battery included in standard package
  • Complex menu structure may require learning curve for beginners
  • VGA output requires separate monitor setup
  • Probe attenuation must be manually matched to avoid errors
M: QW-35-FL

Product Specification

Display

Japanese

Features

2-channel, 60MHz bandwidth

M: QW-35-FL

Product Description

Mastering Signal Analysis with the PeakTech 1240 Digital Oscilloscope

The PeakTech 1240 Digital Oscilloscope stands as a robust tool for engineers and hobbyists alike, designed to simplify complex waveform analysis. This device offers a comprehensive suite of features that make it an essential addition to any electronics workbench. With its high-resolution 8-inch TFT display, users can visualize signals with clarity and precision, ensuring that no detail is missed during critical testing phases.

At the heart of the PeakTech 1240 lies its impressive sampling rate, capable of reaching up to 500 MSa/s. This speed allows for accurate capture of fast-changing signals, making it ideal for troubleshooting modern electronic circuits. The oscilloscope supports multiple trigger modes, including Edge, Video, Slope, and Pulse, providing flexibility when dealing with various signal types. Whether you are analyzing a simple sine wave or a complex digital pulse train, the intuitive control panel ensures smooth operation.

One of the standout capabilities of this unit is its built-in FFT function. By converting time-domain signals into the frequency domain, users can easily identify noise sources, harmonics, and system frequencies. The math functions further enhance its utility, allowing for real-time operations like addition, subtraction, multiplication, and division between channels. This makes it possible to perform advanced calculations directly on the screen without external software.

Connectivity is another strong point, featuring both USB and LAN interfaces for seamless data transfer and network integration. Users can save waveforms, settings, and screenshots internally or to an external USB drive for later review. The inclusion of a VGA output also permits connecting the oscilloscope to larger monitors or projectors, which is beneficial for educational demonstrations or collaborative troubleshooting sessions.

The device prioritizes safety with clear warnings regarding voltage limits and proper grounding procedures. It complies with EU regulations for electromagnetic compatibility and low voltage, ensuring reliable operation in professional environments. The user interface supports multiple languages, making it accessible to a global audience. From automatic calibration to cursor measurements, every aspect of the PeakTech 1240 is designed to streamline the measurement process while maintaining high accuracy.

Key Notes

  • Always ensure probe compensation before taking measurements.
  • Use AC coupling to block DC components when analyzing small AC signals.
  • The band limit feature helps reduce high-frequency noise on specific models.
  • Regular self-calibration is recommended after significant temperature changes.
  • Safety precautions must be followed strictly to prevent equipment damage.
M: QW-35-FL

© Copyright 2026 Manual.ly