Body temperature
Replace the
battery as soon
as possible.
·
6 7
Current battery
capacity is too low.
To protect the environment, dispose of empty
batteries at appropriate collection sites according to
national or local regulations.
Dispose of at public collection point in the EU
countries – 2006/66/EC Directive.
Care and Cleaning
1. The probe (comprising a temperature sensor and a distance
sensor) is the most intricate part of the thermometer, and
should be kept clean and intact to acquire accurate
readings.
Use the following method to clean the probe:
Gently swab the surface of the probe using a cotton bud
soaked in > 75% medical alcohol.
2. If the probe (sensor) is broken, please contact customer
services.
3. Use a piece of soft, dry cloth to clean the display screen and
external surface of the thermometer. If the thermometer is
very dirty, the cloth can be moistened with some medical
alcohol to clean the device.
4. The product is not waterproof. Do not clean the device with
detergents. Do not soak the thermometer in water or other
liquids.
1. This company has not authorized any agency or individual
to carry out product repairs or maintenance. Do not
attempt to disassemble or modify the thermometer if you
suspect functional issues with the device.
2. The IR thermometer is an extremely precise instrument. Any
improper maintenance, disassembly, or modication may
lead to inaccuracies of the product measurements.
3. If you suspect any product issues during the warranty
period, please contact customer services for subsequent
handling.
Maintenance
Disposal
Dispose of the battery in accordance with the
regulation applicable at the place of operation.
Dispose of at public collection point in the EU
countries – 2002/96/EC WEEE Directive.
If you have any queries, please refer to the local
authorities responsible for waste disposal.
Notes
• Please act according to local laws for disposal of used
batteries.
• Take out the battery if you are not going to use the unit for
a long time.
Body temperature varies from person to person and
uctuates during the course of the day. For this reason, it is
suggested to know one's normal, healthy forehead
temperature to correctly determine the temperature.
Body temperature runs approximately from 95.9°F to100°F
(35.5℃-37.8℃). To determine if one has a fever, compare the
temperature detected with the person's normal temperature.
A rise over the reference body temperature of 1°F(1℃) or
more is generally an indication of fever.
Dierent measurement sites(rectal, axillary, oral, frontal,
auricular) will give dierent readings. Therefore it is wrong to
compare the measurement taken from dierent sites.
Rectal
Axillary
Oral
Auricular
36.6℃ to 38℃
34.7℃ to 37.3℃
35.5℃ to 37.5℃
35.8℃ to 38℃
97.9°F-99.1°F
94.5°F-99.1°F
95.9°F-99.5°F
96.4°F-100.4°F
·
Replace the
batteries
· Measurement
distance too long
·
·
·
Product errors and troubleshooting
Item to detect SolutionProblem
·
Battery depleted
· Batteries have been
installed with the
wrong polarity
· Batteries are not
installed properly
Unable to carry out
measurement as
current battery
capacity is too low.
Target temperature is
beyond range of
measurements 89.6℉-
109.2℉(32℃-42.9℃)
Environment temperature
either exceeds the design
range 59℉-104℉(15℃-
40℃) or is unstable
Current state: All
symbols are ashing
on the screen. The
product is not usable.
Follow the
instruction
manual and
repeat the
measurements
Take out the
batteries and
re-install them
correctly.
Replace old
batteries with
new ones
Please contact
customer
services.
When using, shall not touch battery and the patient
simultaneously.
Do not throw batteries into re.
The typical service life of the new and unused batteries is
300 measurements for the operation time is 60s.
The following aretypical temperatures for adults, based
on dierent measurement sites:

Chat with your iHealth PT3 manual using AI

Get instant AI answers from your iHealth PT3 manual

Ask anything about the iHealth PT3. Answers come from this manual, with the pages they are based on.

PT3 Maintenance Schedule

Remind me when maintenance is due
If not used for more than one month
Remove batteries if stored for over a month

Take out the batteries from the thermometer if the device will not be used for more than one month to prevent damage.

As needed / Before use
Clean the IR probe with alcohol swab

Gently swipe the probe surface with a cotton swab dipped in >75% medical alcohol. Let it sit for at least 15 minutes before measuring.

As needed
Wipe exterior and screen with soft dry cloth

Use a soft, dry cloth to clean the display and external surface. If very dirty, moisten the cloth slightly with medical alcohol.

When low battery symbol appears
Replace batteries when capacity is low

Replace old batteries with new ones when the low power symbol flashes or device fails to measure. Ensure correct polarity.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend PT3?

Yes No

Frequently Asked Questions

A

Turn off the device. Press and hold the measurement button for 8 seconds until both symbols flash. Press the button once to select your preferred unit, then hold for 8 seconds again to confirm.

Is this answer helpful?

A

Yes, the iHealth PT3 is safe for babies, children, and adults. However, infants and young children should not operate the device themselves; an adult must take the measurement.

Is this answer helpful?

A

Ensure the forehead is clean and dry, and wait 30 minutes after eating or exercising. Check the battery level and ensure the device has acclimated to the room temperature. Repeat the measurement up to three times.

Is this answer helpful?

A

Batteries typically last for about 300 measurements. Replace them immediately if the low battery icon appears or if the device fails to power on correctly.

Is this answer helpful?

A

No, the device is not waterproof. Do not submerge it in water or use detergents. Clean the exterior with a soft cloth slightly dampened with alcohol.

Is this answer helpful?

A

The warranty period is one year from the date of delivery. Proof of purchase is required for any claims under the warranty terms.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Non-contact measurement ensures hygiene and prevents cross-contamination between users.
  • Fast reading time provides instant results with a simple beep and vibration alert.
  • Dual unit support allows easy switching between Celsius and Fahrenheit for global use.
VS

Disadvantages

  • Accuracy can be affected by environmental factors like direct sunlight or strong EM interference.
  • Requires regular battery replacement as the typical lifespan is around 300 measurements.
  • Not suitable for measuring temperature over scar tissue or areas with inflammation.
M: QW-35-FL

Product Specification

Type

Infrared Thermometer

Power Source

Battery Powered (2x AAA Battery)

Application

On Forehead

Units

°C, °F (Switchable)

Measurement Range

89.6°F to 109.2°F (Body Temperature)

Accuracy

±0.54°F

Measurement Time

1s

Display

Yes

Features

Auto Power Off

M: QW-35-FL

Product Description

Discover the iHealth PT3 Infrared Thermometer

The iHealth PT3 is a cutting-edge infrared thermometer designed to provide quick, non-contact temperature readings for the entire family. This high-tech device measures body heat by detecting infrared energy emitted from the forehead, ensuring a hygienic and efficient way to monitor health conditions. Whether you are checking on a sleeping child or assessing your own well-being, this tool offers peace of mind with its user-friendly design.

Key Features and Performance

This device operates within a measurement range of 89.6°F to 109.2°F (32°C to 42.9°C), making it suitable for detecting fevers accurately. The precision is set at ±0.4°F within the critical range of 95°F to 107.6°F. It features an LED display that shows readings in both Celsius and Fahrenheit, allowing users to switch units easily by holding the measurement button. The thermometer runs on two AAA batteries and includes a low-power indicator to ensure reliability when needed.

Usage and Safety

To use the iHealth PT3, simply aim the probe at the center of the forehead from a distance of approximately 1.18 inches (3 cm). The device vibrates upon successful measurement, providing immediate feedback. For accurate results, ensure the forehead is free from sweat, cosmetics, or dirt, and avoid measuring immediately after eating, drinking, or physical activity. The product is intended for consumer use only and should not replace professional medical advice.

Maintenance and Care

Cleaning the probe gently with a cotton swab dipped in 75% alcohol helps maintain accuracy. Avoid exposing the device to direct sunlight, extreme temperatures, or moisture. Always remove batteries if the device will not be used for more than a month to prevent leakage. The iHealth PT3 is built with durable materials that meet safety standards, ensuring no toxicity or irritation during contact.

Important Notes

  • Do not measure over scar tissue or open wounds.
  • Allow the device to acclimate to room temperature before use if moved from a different environment.
  • Keep out of reach of children to prevent accidental ingestion of batteries.
M: QW-35-FL

© Copyright 2026 Manual.ly