73db1cbf81d17a3d69bf72b150be7e952156 page 7
05/ 2018
TRITEST
®
pro
4
Note:
Phase sequence tests can be carried out even with
the batteries being removed or exhausted.
5. LED torch
Warning!
Potentiallydangerousopticalradiation!
Do not look directly or indirectly via
reflecting surfaces into the LED beam!
Dangertoyourretina!
- The device is provided with a high-power LED
torch
6
with can be switched on and off by press-
ing the push-button
7
.
6. Batteryreplacement
- Do not apply voltage to the device when the bat-
tery compartment is open!
- The battery compartment is located on the back of
the device.
- Slightly press down the catch by means of a
screwdriver and push off the battery compartment
cover in downward direction at the same time.
- Replace the exhausted batteries by three new
ones of type AA (LR06). Make sure that the new
batteries are inserted with correct polarity!
- Push the battery compartment cover back onto
the housing until the catch locks into place with
an audible click.
Note:
The battery compartment cover is provided with an
integrated magnet and a belt clip for attachment of the
device.
7. Technical data
- Regulations: DIN EN 61010-1 and -031, IEC
61010-1 and -31, DIN EN 61557-1 and -7, IEC
61557-1 and -7, DIN EN 62471
- Nominal voltage range: 400 V to 500 V
- Measuring category: CAT III 300 V to earth
- Nominal frequency range f: 50 Hz / 60 Hz
- Current consumption: I
s
< 3.5 mA (500 V)
- Contamination level: 2
- Protection category: IP 40 (DIN VDE 0470-1 IEC /
EN 60529)
4 - first index: protection against access to dan-
gerous parts and protection against solid impuri-
ties of a diameter > 1.0 mm
0 - second index: no protection against water
- Battery: 3 x 1.5 V batteries of type AA (LR06)
- Weight: approx. 250 g
- Measuring line with test handles: length of approx.
1,000 mm
- Operating temperature range: - 15 °C to + 55 °C
- Storage temperature range: - 15 °C to + 55 °C
- Relative air humidity: 20 % to 80 %
8. General maintenance
Clean the exterior of the device with a clean dry cloth.
If there is contamination or deposits in the area of the
battery or the battery housing, clean these areas as
well by means of a dry cloth.
If the device is stored for a longer period of time,
remove the batteries from the device!
9. Environmental protection
At the end of product life, dispose of the
unserviceable device as well as used batte-
ries via appropriate collecting facilities provi-
ded in your community.

Chat with your Benning TRITEST pro manual using AI

Get instant AI answers from your Benning TRITEST pro manual

Ask anything about the Benning TRITEST pro. Answers come from this manual, with the pages they are based on.

TRITEST pro Maintenance Schedule

Before and after each use
Check device functionality

Test the LEDs for phase indication and rotation direction on a known voltage source immediately before and after every use.

As needed
Replace batteries

Replace the three AA (LR06) batteries when the brightness of the LED torch decreases.

Regularly / As needed
Clean device exterior

Clean the outside of the housing with a clean dry cloth. Also clean the battery compartment if contaminated.

Before long-term storage
Remove batteries

If the device is stored for a longer period of time, remove the batteries from the device to prevent damage.

M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend TRITEST pro?

Yes No
0
User Pic

Wellington Larson

6 months ago

Does the Benning TRITEST pro include a flashlight and magnetic mount for easier handling?

0
User Pic

Manual.ly

6 months ago

Yes, the device features an integrated LED flashlight activated by a side button, a magnet on the back, and a belt clip to assist with positioning during use.

M: QW-35-FL
M: QW-35-FL
0
User Pic

Duane Kuvalis

5 months ago

Are the test leads color-coded and labeled for users with color blindness?

M: QW-35-FL

Frequently Asked Questions

A

Yes, the TRITEST pro phase sequence test works fully even when the batteries are removed or completely discharged. However, the LED flashlight will not function without power.

Is this answer helpful?

A

No, the device contains magnets that can affect cardiac pacemakers and implanted defibrillators. Users with these devices must maintain a safe distance from the instrument.

Is this answer helpful?

A

The device is rated for a nominal voltage range of 400 V to 500 V AC. It should only be used in circuits belonging to overvoltage category CAT III with a maximum of 300 V to earth.

Is this answer helpful?

A

Open the battery compartment on the back of the device by pressing the catch and sliding the cover down. Replace the three old AA batteries with new ones, ensuring correct polarity, then slide the cover back until it clicks.

Is this answer helpful?

A

The green LED illuminates to indicate a clockwise (right-hand) rotating field sequence. If the red LED for left-hand rotation lights up instead, the sequence is reversed.

Is this answer helpful?

A

No, the device has an IP 40 rating which protects against solid objects but offers no water protection. You must keep the device dry and free from condensation at all times.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Clear visual indication of phase sequence with distinct red and green LEDs
  • Operates effectively even with removed or dead batteries
  • Includes a powerful integrated LED flashlight for low-light conditions
  • Robust build quality with IP 40 protection against dust and solids
  • Convenient belt clip and magnet for easy attachment to tools or belts
VS

Disadvantages

  • Not waterproof and offers no protection against water ingress
  • Magnets inside the case can interfere with pacemakers and defibrillators
  • Requires careful handling to avoid direct exposure to the bright LED beam
  • Limited to specific voltage ranges and measurement categories
  • Must be used by qualified personnel due to high-voltage risks
M: QW-35-FL

Product Specification

Measurement range

400-500V

M: QW-35-FL

Product Description

Benning Tritest pro Rotating Field Direction Indicator Phase Tester

The Benning Tritest pro is a specialized instrument designed for electricians to verify the phase sequence and direction of rotating fields in three-phase electrical systems. This robust device operates within a nominal voltage range of 400 V to 500 V AC, making it ideal for industrial applications where precise phase rotation checks are critical for motor safety and operation.

Equipped with intuitive LED indicators, the tester provides immediate visual feedback. Three red LEDs confirm the presence of voltage on phases L1, L2, and L3. A fourth red LED signals a counter-clockwise (left-hand) phase sequence, while a green LED indicates a clockwise (right-hand) sequence. This clear distinction helps professionals quickly identify wiring errors before connecting motors or other sensitive equipment.

Beyond its primary function, the unit features a high-power LED flashlight for use in dimly lit environments like switchgear rooms. The design prioritizes user safety with insulated test probes and specific warnings regarding magnetic interference with medical devices such as pacemakers. The device is built to withstand harsh conditions with an IP 40 rating, protecting against solid objects larger than 1 mm, though it is not waterproof.

Maintenance is straightforward, requiring only periodic battery replacement using three standard AA batteries. Interestingly, the phase sequence test remains functional even if the batteries are removed or depleted, ensuring reliability in critical situations. The unit includes a belt clip and magnet on the battery cover for convenient hands-free carrying during field work.

Key Features

  • Direct reading of phase sequence without complex calculations.
  • Integrated high-intensity LED torch for visibility.
  • Safe operation up to CAT III 300 V limits.
  • Durable construction suitable for professional trade use.

Notes

Always ensure all three phases are present before analyzing the sequence indicator. Avoid looking directly into the LED beam to prevent eye damage.

M: QW-35-FL

© Copyright 2026 Manual.ly