996338f8d94f3e91cc3b7b5d3342cb1ba7e9 page 8
11/ 2018
PROFIPOL
®
+
4
correct functioning of the buzzer and of the yellow
LED Ω
K
for continuity.
- Please replace the batteries as soon as the
buzzer, the yellow LED Ω
K
for continuity or the
single-pole phase indication
8
do not work any-
more.
- The LED step indicator
9
works independently of
the battery voltage.
- Test the voltage tester with familiar voltage
sources, e.g. with a 230 V socket.
- Do not use the voltage tester, if the voltage indi-
cation and the phase indication are not working
properly!
4. Checking the absence of voltage of an installa-
tion (fig ure C/ D/ E)
For checking the installation, please test the absence
of voltage by checking the voltage indication and the
single-pole phase indication (the phase indication only
works in an earthed AC voltage mains). The instal-
lation is only free of voltage, if both test circuits (vol-
tage indication and phase indication) are signaling the
absence of voltage.
- Apply the two probe tips
2
and
3
to the system
parts to be tested.
- The level of voltage applied is indicated by means
of the LED step indicator
9
.
- Alternating voltages (AC) are indicated by the
+ LED and the - LED lighting up simultaneously.
- Direct voltages (DC) are indicated by the + LED
or the - LED lighting up. The polarity indication
J
shows the polarity (+ or -) applied to the positive
test probe
3
.
5. External conductor test (phase indication)
(figure E)
- Fully grasp the handles
5
and
6
, in order to
en sure a capacitive coupling to earth.
- Apply the probe tip
3
to the system part to be
tested.
During the single-pole external conductor test
(phase in dication), make absolutely sure not to
touch the probe tip
2
and that it remains contact-
less.
- If the red LED
8
lights up on the display, the
external conductor (phase) of an AC voltage is
applied to this sys tem part.
Note:
The single-pole external conductor test (phase indi-
cation) can be carried out in an earthed mains from
230 V, 50 Hz/ 60 Hz (phase to earth) on. Protective
clothing and insulating condi tions on site might impair
the function.
Attention!
The absence of voltage must be determined additio-
nally by means of a two-pole test.
6. Continuity test (figure F)
- The continuity test must be carried out on sys-
tem parts which are free of voltage. If necessary,
capacitors have to be discharged.
- Apply the two probe tips
2
and
3
to the system
parts to be tested.
- In case of continuity (R < 100 kΩ), an acoustic
signal is emitted and the yellow LED Ω
K
for con-
tinuity lights up.
- If a voltage is applied to the test point, the voltage
tester automatically switches over to the voltage
test function and indicates this function.
7. Cable break detector (figure G)
- The cable break detector is intended for the non-
contact localization of cable breaks on exposed
live lines.
- Fully grasp the display handle
6
and pass the
detector
4
over a live line (e.g. a cable reel or a
chain of lights) from the feeding point (phase) in
direction of the other end of the line.
- As long as the line is not interrupted, the yellow
LED Ω
K
for continuity lights.
- The point of the cable break has been localized as
soon as the yellow LED Ω
K
goes out.
Note:
The cable break detector can be used in earthed
mains from 230 V, 50 Hz/ 60 Hz (phase to earth) on.
Protective clothing and insulating conditions on site
might impair the function.
8. Battery replacement (figure H)
- Do not apply voltage to the device when the bat-
tery com partment
7
is open!
- The battery compartment
7
is located in the bot-
tom part of the display handle
6
.
- Unscrew the screw of the battery compartment
7
until the battery compartment
7
can be pulled off
in downward direction over the connecting cable.
Replace the exhausted batteries by two new bat-
teries of type AAA (LR03). Make sure that the new
batteries are inserted with correct polarity!
- Screw the battery compartment
7
back onto the
display handle
6
.
9. Technical data
- regulation: DIN EN 61243-3: 2015, IEC 61243-3:
2014
- nominal voltage range: 12 V to 690 V AC / DC
- nominal frequency range f: 0 to 500 Hz
- max. indication error: U
n
±15%, ELV U
n
+0% -15%
- Impedance (internal resistance): 124 kΩ
- current consumption: I
S
< 6,0 mA (690 V)
- polarity indication: + LED, - LED
- external conductor test (phase indication):
≥ U
n
230 V, 50 Hz/ 60 Hz
- continuity test: 0 to approx. 100 kΩ, LED Ω
K
+
buzzer, testing current: max. 10 μA
- overvoltage category: CAT III 600 V, CAT II 690 V
- protection category: IP 54 (DIN VDE 0470-1 IEC/
EN 60529)
5 - first index: dustproof
4 - second index: protected against water jets
- max. allowable Duty cycle: 30 s (max. 30 sec-
onds), 240 s off
- battery: 2 x micro, LR03/AAA (1,5 V)
- weight: approx. 200 g
- Length of the display handle incl. probe tip:
approx. 207 mm
- Length of the probe tip: approx. 15 mm
- length of connecting cable: approx. 1,000 mm
- operating temperature and storage temperature
range: - 15 °C to + 55 °C (climatic category N)
10. General maintenance
Clean the exterior of the device with a clean dry cloth.
If there is contamination or deposits in the area of the
battery or the battery housing, clean these areas as
well by means of a dry cloth.
If the device is stored for a longer period of time,
remove the batteries from the device!
11. Environmental protection
Please lead batteries and also the device at
the end of its useful life to the available return
and collection systems

Chat with your Benning PROFIPOL+ manual using AI

Get instant AI answers from your Benning PROFIPOL+ manual

Ask anything about the Benning PROFIPOL+. Answers come from this manual, with the pages they are based on.

PROFIPOL+ Maintenance Schedule

Before and after each use
Perform functional test of the voltage tester

Check the device for correct functioning immediately before and after every use by shorting probe tips and testing on a known voltage source.

As needed / During cleaning
Clean housing and battery compartment

Clean the exterior of the device with a clean dry cloth. If contamination is present in the battery area, clean it with a dry cloth as well.

When storing long-term
Remove batteries from device

If the device is stored for a longer period of time, remove the batteries from the device to prevent damage or leakage.

M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend PROFIPOL+?

Yes No
0
User Pic

W. S.

5 months ago

Is this product easy to install for someone without electrical experience?

0
User Pic

Manual.ly

5 months ago

Yes, the product is designed to be user-friendly and can be installed by individuals without professional electrical training. The instructions are clear, and many users have successfully completed the installation themselves.

M: QW-35-FL
M: QW-35-FL
0
User Pic

Tom Klein

6 months ago

How would you describe the build quality and handling of this item?

M: QW-35-FL

Frequently Asked Questions

A

The device is designed to test nominal voltages ranging from 12 V up to 690 V AC/DC. It is suitable for use in overvoltage categories CAT III up to 600 V and CAT II up to 690 V.

Is this answer helpful?

A

Before and after every use, you must perform a functional test by short-circuiting the probe tips. This should activate the buzzer and light up the yellow continuity LED. If these do not work, replace the batteries immediately.

Is this answer helpful?

A

Yes, you can perform two-pole voltage tests using the LED step indicator even with exhausted batteries. However, other functions like the buzzer and phase indication will not work without power.

Is this answer helpful?

A

The detector uses a sensor on the handle to locate breaks in live cables without contact. You run the sensor along the cable; the yellow LED stays lit until it reaches the break point where it turns off.

Is this answer helpful?

A

The tester requires two Micro batteries, specifically type LR03 or AAA (1.5 V). Ensure they are inserted with the correct polarity as indicated by the symbol inside the compartment.

Is this answer helpful?

A

No, the LED step indicator is designed to show the voltage range, not for precise measurement purposes. It indicates whether voltage is present and roughly how high it is within the specified limits.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Comprehensive voltage detection range from 12 V to 690 V AC/DC
  • Non-contact cable break detector for safe localization of faults
  • Dual-pole and single-pole testing capabilities with clear LED indicators
  • Built-in functional self-test ensures reliability before every use
  • Robust IP54 protection against dust and water splashes
VS

Disadvantages

  • Maximum continuous operation time limited to 30 seconds per cycle
  • Impedance may cause interference voltage misreadings in some scenarios
  • Requires removal of batteries during long-term storage to prevent leakage
  • Single-pole phase test requires full hand coverage of handles for accuracy
  • Not intended for precise measurement but rather for range indication
M: QW-35-FL

Product Specification

Measurement range

12-690V

M: QW-35-FL

Product Description

Benning Profipol Voltage Tester: Essential Safety for Electricians

The Benning Profipol Voltage Tester stands as a critical tool for any professional electrician or electrotechnically trained person. Designed to ensure safety during electrical work, this device offers comprehensive functionality for detecting voltage presence, verifying phase indicators, and locating cable breaks without direct contact. Whether working on residential circuits or industrial installations, the PROFIPOL+ provides reliable data through its intuitive LED display system.

This tester is engineered to handle nominal voltages ranging from 12 V up to AC/DC 690 V. Its robust construction meets strict international standards, including DIN EN 61243-3 and IEC 61243-3, ensuring it performs reliably in demanding environments. The device features dual probe tips for two-pole testing and a specialized sensor for non-contact cable break detection. Users can quickly distinguish between alternating current (AC) and direct current (DC) based on specific LED patterns, while the polarity indicator clarifies positive and negative connections.

Safety remains the paramount feature of the Benning Profipol Voltage Tester. The unit includes insulated handles that must be gripped fully to ensure capacitive coupling to earth during single-pole phase tests. A built-in functional test allows users to verify the buzzer and LEDs before every use, preventing dangerous false readings. The device automatically switches modes if voltage is detected during a continuity check, adding an extra layer of protection against accidental shock.

Maintenance is straightforward, requiring only a dry cloth for cleaning and periodic battery replacement using standard AAA cells. The IP54 rating ensures resistance against dust and water jets, making it suitable for various job site conditions. By adhering to the recommended duty cycle of 30 seconds, users can maximize the longevity and accuracy of this indispensable diagnostic instrument.