7043fbf1a6a9dc7673a17d2361871ecc1d96 page f
05/ 2019
BENNING MM 4
9
Operating Manual
BENNING MM 4
Digital Multimeter with current transducer clamp for:
- AC current measurement
- AC-voltage measurement
- DC-voltage measurement
- Resistance measurement
- Diode testing
- Continuity testing
Contents:
1. Notes for the user
2. Safety notes
3. Scope of supply
4. Description of unit
5. General data
6. Ambient conditions
7. Electrical data
8. Measuring with the BENNING MM 4
9. Maintenance
10. Technical data of the measuring accessories
11. Environmental notice
1. Notes for the user
This Operating Manual is intended for:
- electricians and
- persons possessing knowledge of electrical technology.
The BENNING MM 4 is designed for measurements in dry surroundings. It must
not be used in circuits with rated voltages higher than 600 V (for more details,
see section 6 “Ambient conditions”).
The following symbols are used in the Operating Manual and on the BENNING MM 4
itself:
Application around and removal from HAZARDOUS LIVE
conductors is permitted.
This symbol indicates an electrical hazard.
This symbol indicates sources of danger when using the BENNING MM 4
(see documentation).
This symbol on the BENNING MM 4 indicates that the unit is
protection insulated (safety class II).
This symbol appears in the display for a discharged battery.
This symbol indicates the “continuity-testing” application. The
buzzer provides an audible signal.
This symbol indicates the “diode-testing” application.
(DC)-voltage.
(AC)-voltage or current.
Earth (voltage to earth).
Note
After unmark the adhesive label „Warnung...“ (on battery compartment lid) the
English text appears.

Chat with your Benning MM 4 manual using AI

Get instant AI answers from your Benning MM 4 manual

Ask anything about the Benning MM 4. Answers come from this manual, with the pages they are based on.

MM 4 Maintenance Schedule

Remind me when maintenance is due
Yearly
Calibrate the multimeter

Send the device to Benning Service Center for calibration to maintain measurement accuracy. Recommended interval is once per year.

Show in the manual (page 14)
As needed
Replace batteries

Replace the two 1.5V batteries when the battery symbol appears in the display. Ensure device is voltage-free before opening.

Show in the manual (page 14)
Regularly
Clean housing and battery compartment

Clean exterior with a dry cloth. Do not use solvents or abrasives. Clean battery contacts if electrolyte leakage or white deposits are found.

Show in the manual (page 13)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend MM 4?

Yes No
0
User Pic

Ruthe Watsica

5 months ago

Is this measuring device compact and portable enough for service technicians to carry easily?

0
User Pic

Manual.ly

5 months ago

Yes, the device is designed to be small and handheld, making it ideal for service and customer support work. It includes all the essential features you need for your tasks.

M: QW-35-FL
M: QW-35-FL
0
User Pic

edward59

4 months ago

Does this unit come with all necessary accessories or does it require additional purchases for basic operation?

M: QW-35-FL

Frequently Asked Questions

A

The device is rated for a maximum of 600 V in Category II circuits and 300 V in Category III circuits against earth potential. Always observe safety limits to prevent electric shock.

Is this answer helpful?

A

Attach the current clamp accessory firmly to the multimeter. Switch to AC current mode by pressing the blue function button for two seconds. Open the clamp jaws, surround a single live conductor, and read the value on the display.

Is this answer helpful?

A

No, the device is designed only for dry surroundings. It has an IP30 protection rating which guards against solid objects but offers no protection against water ingress.

Is this answer helpful?

A

It uses two 1.5 V micro batteries (IEC LR03). The display will show a battery symbol when the voltage drops below the required operating level.

Is this answer helpful?

A

Yes, the HOLD/REL button allows you to freeze the displayed measurement value. Pressing it once holds the value, while holding it for two seconds activates the relative value mode.

Is this answer helpful?

A

For optimal accuracy, Benning recommends calibrating the unit once per year through their service center to maintain compliance with technical specifications.

Is this answer helpful?

A

The package contains the multimeter, current clamp attachment, black safety test lead, two red test probes, a compact protective case, two micro batteries, and the operating manual.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Measures AC current up to 300 A without breaking the circuit
  • Clear LCD display with auto-ranging capabilities
  • Includes safety test leads and protective carrying case
  • Buzzer alerts for continuity testing under 50 ohms
  • Dual voltage measurement for DC and AC applications
VS

Disadvantages

  • Cannot measure temperature, humidity, or other environmental factors
  • Requires manual range selection for some high-precision tasks
  • No water resistance rating beyond IP30 protection
  • Maximum altitude limit of 2000 meters for operation
  • Battery life depends on usage frequency and alkaline quality
M: QW-35-FL

Product Specification

Measurement range

max. 300A, max. 600V, max. 42MΩ

Package contents

Bag

M: QW-35-FL

Product Description

Discover the Benning MM 4 Current Clamp Multimeter

The Benning MM 4 Current Clamp Multimeter is a versatile digital tool designed for electricians and technicians who require precision in dry environments. This robust device combines a standard multimeter with an attachable current transducer clamp, allowing users to measure alternating current without breaking the circuit. Whether you are troubleshooting electrical panels or performing routine maintenance, this instrument provides reliable readings for voltage, resistance, and continuity.

Designed with safety as a priority, the Benning MM 4 operates within specific overvoltage categories, ensuring protection up to 600 volts in category II circuits. The unit features a clear liquid crystal display that shows measurement values, polarity, and battery status at a glance. Users can easily switch between functions like direct voltage, alternating voltage, resistance, diode testing, and continuity checks using the intuitive sliding switch and function buttons. The included buzzer provides audible feedback during continuity tests, making it easier to verify connections quickly.

The package includes essential accessories such as safety test leads, red test probes, a compact protective case, and two micro batteries. The current clamp attachment expands the device capabilities significantly, enabling AC current measurements from 0.1 A to 300 A. Its ergonomic design allows for a maximum conductor diameter of 29 mm, fitting most standard cables. Maintenance is straightforward, with clear instructions for battery replacement and cleaning, ensuring long-term reliability. This multimeter stands out as an essential tool for anyone needing accurate, safe, and efficient electrical measurements.

M: QW-35-FL

© Copyright 2026 Manual.ly