8
sure a capacitive coupling to earth.
- Apply the probe tips L1/-
2
and L2/+
3
to two external
conductors (phases) and check whether the external con-
ductor voltage of e.g. 400 V is applied.
- A clockwise phase sequence (phase L1 before phase L2)
is given, if the green LED „►“ of the phase sequence in-
dication
L
and the symbol of the phase sequence
indication
P
light up on the LC display
6
.
- A counter-clockwise phase sequence (phase L2 before
phase L1) is given, if the green LED „◄“ of the phase
sequence indication
L
and the symbol of the phase
sequence indication
P
light up on the LC display
6
.
- The phase sequence test always requires a countercheck
with the probe tips L1/-
2
and L2/+
3
being inverted dur-
ing which the phase sequence must change.
Note:
The phase sequence test can be carried out in an earthed
three-phase mains from 400 V - 900 V, 50/60 Hz (phase to
phase) on. Protective clothing and insulating conditions on site
might impair the function.
8. Continuity test (gure I)
- The continuity test must be carried out on system parts
which are free of voltage. If necessary, capacitors have to
be discharged.
- Apply the two probe tips L1/-
2
and L2/+
3
to the system
parts to be tested.
- In case of continuity (R < 100 kΩ), an acoustic signal is
emitted and the yellow LED Ω
M
for continuity lights up.
- If a voltage is applied to the test point, the voltage tester
automatically switches over to the voltage test function
and indicates this function.
9. Resistance measurement (gure J)
- The resistance measurement must be carried out on sys-
tem parts which are free of voltage. If necessary, capaci-
tors have to be discharged.
- Short-circuit the probe tips L1/-
2
and L2/+
3
and press
the push-button
7
of the display handle L2
9
once until
the kΩ symbol and „Ohm“ are shown on the LC display
6
. Display: „OL“ stands for a measured value which is
outside the measuring range.
- The resistance measurement function is active for approx.
10 seconds.
- Apply the probe tips L1/-
2
and L2/+
3
to the system
parts to be tested in order to measure resistances from
0.1 kΩ to 300 kΩ.
Note:
If required, it is possible to carry out a null balance with the
resistance measurement function being activated. For this pur-
pose, short-circuit the probe tips L1/-
2
and L2/+
3
and press
and hold the push-button
7
of the display handle L2
9
for
approx. 2 seconds until „0.0“ kΩ is shown on the LC display.
10. Diode test (gures K/L)
- The diode test must be carried out on system parts which
are free of voltage. If necessary, capacitors have to be dis-
charged.
- Short-circuit the probe tips L1/-
2
and L2/+
3
and press
the push-button
7
of the display handle L2
9
twice until
the diode symbol and „diod“ are shown on the LC
display
6
. Display: „OL“ VDC
- The diode test is active for approx. 10 seconds.
- Apply the probe tip L1/-
2
to the cathode and the probe
tip L2/+
3
to the anode of the diode to determine the con-
ducting-state voltage between 0.3 V and 2 V. In case of a
defective (broken down) diode, a voltage value of approx.
0.0 V will be displayed.
- In case of a diode tested in non-conducting direction, the
LC display shows „OL“.
11. Cable break detector (gure M)
- The cable break detector is intended for the non-contact
localization of cable breaks on exposed live lines.
- Switch the voltage tester on by briefly actuating the push-
button
7
of the display handle L2
9
(remains switched
on for approx. 10 seconds!). When the device is switched
on, the display shows „0.0“.
- Fully grasp the display handle L2
9
and pass the detec-
tor
5
over a live line (e.g. a cable reel or a chain of lights)
from the feeding point (phase) in direction of the other end
of the line.
- As long as the line is not interrupted, the yellow LED Ω
M
for continuity is flashing.
- The point of the cable break has been localized as soon as
the yellow LED Ω
M
goes out.
Note:
The cable break detector may grounded power from 230 V,
50/60 Hz (phase to earth) are used. Insulating protective cloth-
ing and site conditions can affect the function.
12. Measuring point/display illumination (gure N)
- The measuring point illumination
4
can be switched on
with the probe tips being open by actuating the push-but-
ton
7
of the display handle L2
9
(1 second).
- The off automatically after 10 seconds
- The background lighting of the LC display
6
is activated
automatically by means of a light sensor
N
.
13. Battery replacement (gure O)
- Do not apply voltage to the device when the battery com-
partment is open!
- Please replace the batteries as soon as the
symbol
is shown on the LC display
6
.
- The battery compartment is located on the back of the dis-
play handle L2/+
9
.
- Unscrew the screw of the battery compartment cover and
replace the used batteries by two new micro batteries
(LR03/AAA).

Chat with your Benning DUSPOL digital manual using AI

Get instant AI answers from your Benning DUSPOL digital manual

Ask anything about the Benning DUSPOL digital. Answers come from this manual, with the pages they are based on.

DUSPOL digital Maintenance Schedule

As needed
Replace batteries when low battery symbol appears

Replace the two Micro LR03/AAA batteries as soon as the discharged battery symbol is shown on the LC display.

Show in the manual (page 11)
Before and after each use
Perform functional test before checking absence of voltage

Check the voltage tester for correct functioning immediately before and after using it to ensure safety.

When storing long-term
Remove batteries from device during storage

If the device is stored for a longer period of time, remove the batteries from the device to prevent damage.

As needed
Clean housing and battery compartment with dry cloth

Clean the exterior of the device and any contamination in the battery area with a clean, dry cloth.

M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend DUSPOL digital?

Yes No
0
User Pic

Dan King

4 months ago

Is calibration service necessary for this device, or can I skip it?

0
User Pic

Manual.ly

4 months ago

Based on user feedback, the calibration service is not required. The device performs its intended function accurately out of the box without additional calibration steps.

M: QW-35-FL
M: QW-35-FL
0
User Pic

Jaleel Marquardt

6 months ago

Why were batteries already installed in the packaging when I received the item?

M: QW-35-FL

Frequently Asked Questions

A

Perform a functional test by short-circuiting the probe tips and holding the push-button for three seconds. The buzzer should sound, and all LEDs and the display segments must light up. You should also test it on a known voltage source like a 230 V socket.

Is this answer helpful?

A

Yes, by short-circuiting the probes and pressing the button three times until Lo U appears. This activates a low-volt range allowing measurements from 1.0 V to 11.9 V, though frequency indication is disabled in this mode.

Is this answer helpful?

A

The vibration motor helps distinguish between operating voltage and interference voltages. By activating both buttons, you switch to a low internal resistance mode which suppresses reactive voltages and discharges capacitors.

Is this answer helpful?

A

Locate the battery compartment on the back of the display handle. Unscrew the cover, remove the old AAA batteries, insert two new ones ensuring correct polarity, and screw the cover back on tightly.

Is this answer helpful?

A

It has an IP65 rating, meaning it is dust-tight and protected against water jets. It can be used in rain, but should not be submerged in water.

Is this answer helpful?

A

If the voltage exceeds 1,050 V AC or 1,250 V DC, the display will show OL and all step-indicator LEDs will flash to warn of overload.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Distinguishes between operating voltage and interference voltages using a load connection and vibration motor
  • Comprehensive testing capabilities including continuity, resistance, diode, and cable break detection
  • High safety rating with IP65 protection against dust and water jets for use in harsh environments
  • Automatic self-test function ensures all components like LEDs and buzzer are working correctly before use
  • Dual-handle design with insulated grips ensures safe handling during live circuit testing
VS

Disadvantages

  • Requires a minimum voltage of 9 V to activate, limiting use on very low power sources without special mode
  • Battery life may be reduced during extended load tests due to the high current draw of the vibration motor
  • Phase sequence indication only works in earthed networks at 50/60 Hz, limiting global applicability
  • Cannot be used with the battery compartment open, requiring careful management of power access
  • Maximum duty cycle is limited to 30 seconds to prevent overheating, requiring pauses during prolonged testing
M: QW-35-FL

Product Specification

Measurement range

1-1000V

M: QW-35-FL

Product Description

Benning Digital Voltage Tester with Bag - Essential Safety for Professionals

The Benning Digital Voltage Tester with Bag is a robust and reliable tool designed for qualified electricians who demand precision and safety in their daily work. This device, known as the DUSPOL digital, represents a significant advancement in electrical testing equipment by combining multiple diagnostic functions into a single, ergonomic unit. Whether you are checking for voltage absence, testing phase sequences, or locating cable breaks, this tester provides clear visual and auditory feedback to ensure your safety.

Equipped with an intuitive LC display and a multi-level LED indicator, the tester offers immediate insights into the electrical environment. It can measure alternating current up to 1,000 V and direct current up to 1,200 V with high accuracy. The inclusion of a vibration motor allows users to distinguish between operating voltage and interference voltages, a critical feature when dealing with complex installations where stray currents might cause false readings. The device automatically switches on when it detects a voltage of at least 9 V, ensuring that you are never caught off guard during an inspection.

Designed with user safety as the top priority, the tester features insulated handles and requires a specific two-pole test to confirm the absence of voltage, adhering to strict safety standards like DIN EN 61243-3. The built-in self-test function verifies the integrity of the buzzer, LEDs, and display before every use, giving you confidence in your results. Additionally, the low-volt mode allows for precise measurements down to 1.0 V, making it versatile for various applications beyond standard mains voltage checks.

The package includes a durable carrying bag, protecting the instrument from dust, moisture, and physical damage during transport. With its IP65 rating, the tester is resistant to water jets and dust, making it suitable for use in harsh industrial environments or outdoor conditions. Regular maintenance is simple, involving just a dry cloth for cleaning and timely battery replacement using standard AAA cells. For professionals seeking a comprehensive solution for electrical diagnostics, the Benning Digital Voltage Tester with Bag stands out as a trusted companion that combines functionality, durability, and safety.

M: QW-35-FL

© Copyright 2026 Manual.ly