Manual.ly Logo

Benning CM 9-1 Manual

0.0 · 0 Ratings

PDF manual · 46 Pages

English

M: QW-35-FL
page

/ 46

Loading...
aef559a9656eecfc3bcfb6a4df0785377b25 page 1a
10/ 2020
BENNING CM 9-1
26
9.1 Securing the instrument
Under certain circumstances safe operation of the BENNING CM 9-1 is no longer ensured, for
example in the case of:
- Visible damage of the casing.
- Incorrect measurement results.
- Recognisable consequences of prolonged storage under improper conditions.
- Recognisable consequences of extraordinary transportation stress.
In such cases the BENNING CM 9-1 must be switched off immediately, disconnected from the
measuring points and secured to prevent further utilisation.
9.2 Cleaning
Clean the casing externally with a clean dry cloth (exception: special cleaning wipers). Avoid
using solvents and/ or scouring agents for cleaning the instrument. It is important to make sure
that the battery compartment and battery contacts are not contaminated by leaking electrolyte.
If electrolyte contamination or white deposits are present in the region of the batteries or battery
casing, clean them too with a dry cloth.
9.3 Battery replacement
Before opening the BENNING CM 9-1, make sure that it is free of voltage!
Electrical danger!
The BENNING CM 9-1 is supplied by means of two 1.5 V batteries of type AAA (IEC LR03).
Battery replacement is required, if the battery symbol appears on the display
9
. Proceed
as follows to replace the batteries:
- Disconnect the safety measuring leads from the measuring circuit.
- Disconnect the safety measuring leads from the BENNING CM 9-1.
- Set the rotary switch
5
to the switch setting “OFF”.
- Lay the BENNING CM 9-1 face down and release the screws of the battery compartment
cover.
- Lift the battery compartment lid (in the housing recess area) from the bottom section.
- Replace the exhausted batteries by two new ones of type AAA (LR03). Make sure that the
new batteries are inserted with correct polarity!
- Place the battery compartment cover onto the bottom part and tighten the screw.
See figure 12: Battery replacement
Make your contribution to environmental protection! Do not dispose of
discharged batteries in the household garbage. Instead, take them to a
collecting point for discharged batteries and special waste material. Please
inform yourself in your community.
9.4 Calibration
Benning guarantees compliance with the technical and accuracy specifications stated in the
operating manual for the first 12 months after the delivery date.
To maintain the specified accuracy of the measurement results, the instrument must be
recalibrated at regular intervals by our factory service. We recommend a recalibration interval of
one year. Send the unit to the following address:
Benning Elektrotechnik & Elektronik GmbH & CO. KG
Service Centre
Robert-Bosch-Str. 20
D - 46397 Bocholt
10. Technical data of the measuring accessories
- Standard: EN 61010-031,
- Maximum rated voltage to earth () and measuring category:
With push-on caps: 1000 V CAT III, 600 V CAT IV,
Without push-on caps: 1000 V CAT II,
- Maximum rated current: 10 A,
- Protective class II (), continuous double or reinforced insulation,
- Contamination class: 2,
- Length: 1.4 m, AWG 18,
- Environmental conditions:
Maximum barometric elevation for making measurements: 2000 m,
Temperatures: 0 °C to + 50 °C, humidity 50 % to 80 %
- Only use the test leads if in perfect and clean condition as well as according to this manual,
since the protection provided could otherwise be impaired.

Chat with your Benning CM 9-1 manual using AI

Get instant AI answers from your Benning CM 9-1 manual

Ask anything about the Benning CM 9-1. Answers come from this manual, with the pages they are based on.

CM 9-1 Maintenance Schedule

Remind me when maintenance is due
Yearly
Calibrate the device at factory service

Send the unit to Benning Service Center for recalibration to maintain specified accuracy. Recommended interval is one year.

Show in the manual (page 26)
Regularly
Clean the housing with a dry cloth

Wipe the casing externally with a clean dry cloth. Do not use solvents or scouring agents. Ensure battery compartment is free of electrolyte leaks.

Show in the manual (page 26)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend CM 9-1?

Yes No

Frequently Asked Questions

A

The device is rated for Overvoltage Category III with a maximum of 600 V and Category IV with a maximum of 300 V. It must not be used in circuits exceeding these limits to ensure user safety.

Is this answer helpful?

A

Press and hold the ZERO/LPF button for two seconds. This activates the filter between 40 Hz and 70 Hz, which helps suppress high-frequency noise from frequency converters.

Is this answer helpful?

A

The BENNING CM 9-1 is powered by two 1.5 V micro batteries, specifically the IEC LR03 or AAA type. Battery replacement is required when the low battery symbol appears on the display.

Is this answer helpful?

A

No, the BENNING CM 9-1 is designed exclusively for dry environments. It has an IP 30 rating, which offers protection against solid objects but no protection against water.

Is this answer helpful?

A

When the input exceeds the selected range, the digital display will show "0L." indicating an overload. Note that there is no specific warning signal for complete overload conditions.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • True RMS measurement capability ensures accurate readings on non-sinusoidal waveforms
  • Complies with CAT III 600 V and CAT IV 300 V safety standards for high-risk environments
  • Integrated low-pass filter effectively suppresses high-frequency interference from inverters
  • Acoustic continuity buzzer activates below 45 ohms for quick circuit verification
  • Large 4-digit LCD display with automatic range selection simplifies reading results
VS

Disadvantages

  • No built-in fuse requires careful handling to prevent internal damage during overloads
  • Battery life may decrease significantly if the backlight or acoustic tests are used frequently
  • Device cannot be opened or repaired by the user, necessitating professional service for issues
  • Limited to dry environments and cannot withstand moisture or water exposure
  • Accuracy can drift outside the specified temperature range of 18 to 28 degrees Celsius
M: QW-35-FL

Product Specification

Measurement Range

max. 60A, max. 600V, 600kΩ

M: QW-35-FL

Product Description

BENNING CM 9-1 Current Clamp Multimeter: Precision and Safety for Electrical Professionals

The BENNING CM 9-1 stands as a robust solution for electricians and technicians requiring precise measurements in complex electrical environments. Designed strictly according to DIN EN 61557-13, this True RMS leakage current clamp multimeter offers a comprehensive suite of diagnostic capabilities essential for maintaining modern electrical systems. Whether you are troubleshooting industrial machinery or inspecting residential wiring, this tool ensures accuracy where it matters most.

At the heart of the BENNING CM 9-1 is its ability to measure leakage currents, including differential and protective conductor currents, with high reliability. The device features a large 4-digit LCD display that clearly presents readings up to 6000 counts, ensuring that even subtle variations in voltage or current are easily visible. Its design prioritizes user safety, adhering to CAT III 600 V and CAT IV 300 V standards, making it suitable for use in distribution circuits and feed-in points without compromising operator protection.

Beyond leakage detection, the multimeter excels in measuring AC and DC voltages, alternating currents, and resistance values. The inclusion of a low-pass filter (LPF) allows users to suppress high-frequency interference signals often generated by frequency converters, providing cleaner data in noisy environments. For continuity testing, an integrated buzzer provides immediate acoustic feedback when resistance drops below 45 ohms, streamlining fault identification. The unit is powered by two standard AAA batteries, offering a battery life of approximately 40 to 60 hours depending on usage patterns.

This versatile instrument comes complete with safety-rated test leads, a protective carrying case, and detailed instructions in multiple languages. Its compact form factor and ergonomic opening lever make it easy to handle around various conductor sizes, with a maximum jaw opening of 23 mm. By combining rigorous safety protocols with advanced measurement technology, the BENNING CM 9-1 remains an indispensable asset for professionals dedicated to electrical integrity and safety.

M: QW-35-FL

© Copyright 2026 Manual.ly