(grey) J for approx. 3 seconds.
9.1 Securing the instrument
Under certain circumstances safe operation of the BENNING CM 5-1 is no
longer ensured, for example in the case of:
- Visible damage of the casing.
- Incorrect measurement results.
- Recognisable consequences of prolonged storage under improper condi-
tions.
- Recognisable consequences of extraordinary transportation stress.
- Failure of the self-test; „FAIL“ is shown on the display.
In such cases the BENNING CM 5-1 must be switched off immediately, discon-
nected from the measuring points and secured to prevent further utilisation.
9.2 Cleaning
Clean the exterior of the housing with a clean dry cloth (exception: special
cleaning wipers). Avoid using s olvents and/ or scouring agents for cleaning the
instrument. It is important to make sure that the battery compartment and bat-
tery contacts are not contaminated by leaking electrolyte.
If electrolyte contamination or white deposits occur in the area of the batteries
or battery compartment, clean them too with a dry cloth.
9.3 Battery replacement
Before opening the BENNING CM 5-1, make sure that it is free
of voltage! Electrical danger!
The BENNING CM 5-1 is fed by a 9 V block battery.
A battery replacement (see figure 7) is required, if the battery symbol 9 appears
on the display .
Proceed as follows to replace the batteries:
- Disconnect the safety measuring leads from the measuring circuit.
- Disconnect the safety measuring leads from the BENNING CM 5-1.
- Switch off the BENNING CM 5-1.
- Lay the BENNING CM 5-1 face down and release the screws of the battery
compartment cover.
- Lift the battery compartment lid (in the housing recess area) from the bottom
part.
- Lift the discharged battery from the battery compartment and disconnect the
battery supply lines from the battery.
- The new battery have to be connected to the battery supply lines, and
arrange these such that they are not crushed between the housing parts.
Then place the battery into the battery compartment provided for this pur-
pose.
- Place the battery compartment cover onto the bottom part and tighten the
screw.
See figure 7: Battery replacement
Make your contribution to environmental protection!
Do not dispose of discharged batteries in the household
garbage. Instead, take them to a collecting point for discharged
batteries and special waste material. Please inform yourself in
your community.
9.4 Calibration
Benning guarantees compliance with the technical and accuracy specifications
stated in the operating manual for the first 12 months after the delivery date.
To maintain the specified accuracy of the measurement results, the instrument
must be recalibrated at regular intervals by our factory service. We recommend
a recalibration interval of one year. Send the multimeter to the following address:
Benning Elektrotechnik & Elektronik GmbH & CO. KG
Service Centre
Robert-Bosch-Str. 20
D - 46397 Bocholt
10. Technical data of the measuring accessories
- Standard: EN 61010-031,
- Maximum rated voltage to earth (
) and measuring category:
With push-on caps: 1000 V CAT III, 600 V CAT IV,
Without push-on caps: 1000 V CAT II,
- Maximum rated current: 10 A,
- Protective class II (
), continuous double or reinforced insulation,

Chat with your Benning CM 5-1 manual using AI

Get instant AI answers from your Benning CM 5-1 manual

Ask anything about the Benning CM 5-1. Answers come from this manual, with the pages they are based on.

CM 5-1 Maintenance Schedule

Remind me when maintenance is due
Yearly
Calibrate the device at factory service

To maintain specified accuracy, send the instrument to Benning Service Center for recalibration. The recommended interval is one year.

Show in the manual (page 23)
Regularly
Clean the housing with a dry cloth

Wipe the exterior regularly with a clean dry cloth and cleaning agent. Do not use polishing agents or solvents.

Show in the manual (page 23)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend CM 5-1?

Yes No

Frequently Asked Questions

A

The device can measure up to 1000 V DC and 750 V AC. It is rated for CAT III 1000 V and CAT IV 600 V applications.

Is this answer helpful?

A

AUTOTEST automatically identifies whether you need to measure voltage, current, resistance, or diodes and selects the best range without manual input.

Is this answer helpful?

A

Yes, it uses True RMS technology to provide accurate readings on non-sinusoidal waveforms, though some additional error may occur at high crest factors.

Is this answer helpful?

A

If the self-test fails, the display will show FAIL. You should stop using the device immediately and contact service for calibration or repair.

Is this answer helpful?

A

A single 9V alkaline battery typically lasts about 125 hours of operation before needing replacement.

Is this answer helpful?

A

No, it has an IP 30 rating which protects against solid objects larger than 2.5 mm but offers no protection against water.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • AUTOTEST function automatically selects the correct measurement mode and range for efficiency.
  • High safety rating supports CAT III 1000 V and CAT IV 600 V for hazardous environments.
  • True RMS technology ensures accurate readings on non-sinusoidal waveforms.
  • Large LCD with auto backlight improves readability in low-light conditions.
  • Durable construction with IP 30 protection against solid objects.
VS

Disadvantages

  • Battery life is limited to approximately 125 hours under typical usage.
  • Device cannot be opened or repaired by the user; requires professional service.
  • Accuracy may decrease slightly when conductors are not clamped centrally.
  • Low voltage DC measurements below 2.1 V are not supported.
  • No data logging or Bluetooth connectivity for remote monitoring.
M: QW-35-FL

Product Specification

Measurement Range

max. 600A, max. 1000V, max. 10kΩ

Package Contents

Bag

M: QW-35-FL

Product Description

Benning CM 5-1 Clamp Meter-Multimeter: Precision and Safety in Every Measurement

The Benning CM 5-1 is a versatile digital clamp meter designed for professionals who demand accuracy and safety in their electrical work. This robust device combines the functionality of a standard multimeter with a powerful current clamp, making it ideal for measuring direct and alternating voltage, current, resistance, and performing continuity and diode tests. Whether you are an electrician or a maintenance technician, this tool streamlines your workflow with advanced features that ensure reliable results.

At the heart of the Benning CM 5-1 is the innovative AUTOTEST function. This intelligent system automatically detects the type of measurement required and selects the optimal range, saving you time and reducing the risk of user error. The AutoSense feature guides you through every step, ensuring you are always using the correct settings for DC or AC measurements up to 600 A and 750 V AC. The large, clear LCD display provides easy-to-read values, while the automatic backlight ensures visibility even in dimly lit environments.

Safety is paramount with the Benning CM 5-1. Built to meet strict international standards including CAT III 1000 V and CAT IV 600 V, it protects users from high-voltage hazards. The device features a self-test function that alerts you if any internal issues arise, displaying FAIL on the screen if a problem is detected. Additionally, the protective class II insulation guarantees double protection against electric shock. The unit also includes a Hold function to freeze readings for easier analysis and an Auto Power Off feature to conserve battery life after 20 minutes of inactivity.

Designed for durability and ease of use, the Benning CM 5-1 comes with a compact protective pouch and high-quality safety leads rated for 10 A. Its ergonomic design allows for comfortable handling during extended periods, and the large jaw opening accommodates cables up to 30 mm in diameter. With a True RMS measurement capability, it delivers accurate readings even on non-sinusoidal waveforms, making it a trusted companion for complex electrical diagnostics.

M: QW-35-FL

© Copyright 2026 Manual.ly