53aefd00ee84ab471d185944e5350f269a16 page 10
BENNING CM 5-1
05/ 2019
10
Operating instructions
BENNING CM 5-1
Digital current clamp multimeter with AUTOTEST function for
- Direct voltage measurements
- Alternating voltage measurements
- Direct current measurements
- Alternating current measurements
- Resistance measurements
- Continuity testing
- Diode testing
Table of contents
1. User notes
2. Safety note
3. Scope of delivery
4. Unit description
5. General information
6. Ambient conditions
7. Electrical specifications
8. Measuring with the BENNING CM 5-1
9. Maintenance
10. Technical data of the measuring accessories
11. Environmental note
1. User notes
These operating instructions are intended for
- qualified electricians and
- electrotechnically trained persons.
The BENNING CM 5-1 is intended for making measurements in dry environ-
ment. It must not be used in power circuits with a nominal voltage higher than
1000 V DC and 750 V AC (More details in Section 6. “Ambient conditions”).
The following symbols are used in these operating instructions and on the
BENNING CM 5-1:
Application around and removal from HAZARDOUS LIVE
conductors is permitted.
Warning of electrical danger!
Indicates instructions which must be followed to avoid danger to
persons.
Important, comply with the documentation!
The symbol indicates that the information provided in the operating
instructions must be followed with in order to avoid risks.
This symbol on the BENNING CM 5-1 means that the
BENNING CM 5-1 is totally insulated (protection class II).
This symbol on the BENNING CM 5-1 means that the
BENNING CM 5-1 complies with the EU directives.
This symbol appears on the display to indicate a discharged
battery.
This symbol designates the „continuity test“ range.
The buzzer is used for the acoustic result output.
(DC) Direct voltage or current.
(AC) Alternating voltage or current.
Ground (Voltage against ground).
Note
After unmark the adhesive label „Warnung...“ (on battery compartment lid) the
English text appears.

Chat with your Benning CM 5-1 manual using AI

Get instant AI answers from your Benning CM 5-1 manual

Ask anything about the Benning CM 5-1. Answers come from this manual, with the pages they are based on.

CM 5-1 Maintenance Schedule

Remind me when maintenance is due
Yearly
Calibrate the device at factory service

To maintain specified accuracy, send the instrument to Benning Service Center for recalibration. The recommended interval is one year.

Show in the manual (page 23)
Regularly
Clean the housing with a dry cloth

Wipe the exterior regularly with a clean dry cloth and cleaning agent. Do not use polishing agents or solvents.

Show in the manual (page 23)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend CM 5-1?

Yes No

Frequently Asked Questions

A

The device can measure up to 1000 V DC and 750 V AC. It is rated for CAT III 1000 V and CAT IV 600 V applications.

Is this answer helpful?

A

AUTOTEST automatically identifies whether you need to measure voltage, current, resistance, or diodes and selects the best range without manual input.

Is this answer helpful?

A

Yes, it uses True RMS technology to provide accurate readings on non-sinusoidal waveforms, though some additional error may occur at high crest factors.

Is this answer helpful?

A

If the self-test fails, the display will show FAIL. You should stop using the device immediately and contact service for calibration or repair.

Is this answer helpful?

A

A single 9V alkaline battery typically lasts about 125 hours of operation before needing replacement.

Is this answer helpful?

A

No, it has an IP 30 rating which protects against solid objects larger than 2.5 mm but offers no protection against water.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • AUTOTEST function automatically selects the correct measurement mode and range for efficiency.
  • High safety rating supports CAT III 1000 V and CAT IV 600 V for hazardous environments.
  • True RMS technology ensures accurate readings on non-sinusoidal waveforms.
  • Large LCD with auto backlight improves readability in low-light conditions.
  • Durable construction with IP 30 protection against solid objects.
VS

Disadvantages

  • Battery life is limited to approximately 125 hours under typical usage.
  • Device cannot be opened or repaired by the user; requires professional service.
  • Accuracy may decrease slightly when conductors are not clamped centrally.
  • Low voltage DC measurements below 2.1 V are not supported.
  • No data logging or Bluetooth connectivity for remote monitoring.
M: QW-35-FL

Product Specification

Measurement Range

max. 600A, max. 1000V, max. 10kΩ

Package Contents

Bag

M: QW-35-FL

Product Description

Benning CM 5-1 Clamp Meter-Multimeter: Precision and Safety in Every Measurement

The Benning CM 5-1 is a versatile digital clamp meter designed for professionals who demand accuracy and safety in their electrical work. This robust device combines the functionality of a standard multimeter with a powerful current clamp, making it ideal for measuring direct and alternating voltage, current, resistance, and performing continuity and diode tests. Whether you are an electrician or a maintenance technician, this tool streamlines your workflow with advanced features that ensure reliable results.

At the heart of the Benning CM 5-1 is the innovative AUTOTEST function. This intelligent system automatically detects the type of measurement required and selects the optimal range, saving you time and reducing the risk of user error. The AutoSense feature guides you through every step, ensuring you are always using the correct settings for DC or AC measurements up to 600 A and 750 V AC. The large, clear LCD display provides easy-to-read values, while the automatic backlight ensures visibility even in dimly lit environments.

Safety is paramount with the Benning CM 5-1. Built to meet strict international standards including CAT III 1000 V and CAT IV 600 V, it protects users from high-voltage hazards. The device features a self-test function that alerts you if any internal issues arise, displaying FAIL on the screen if a problem is detected. Additionally, the protective class II insulation guarantees double protection against electric shock. The unit also includes a Hold function to freeze readings for easier analysis and an Auto Power Off feature to conserve battery life after 20 minutes of inactivity.

Designed for durability and ease of use, the Benning CM 5-1 comes with a compact protective pouch and high-quality safety leads rated for 10 A. Its ergonomic design allows for comfortable handling during extended periods, and the large jaw opening accommodates cables up to 30 mm in diameter. With a True RMS measurement capability, it delivers accurate readings even on non-sinusoidal waveforms, making it a trusted companion for complex electrical diagnostics.

M: QW-35-FL

© Copyright 2026 Manual.ly