To replace the batteries, proceed as follows:
- Remove the black and red measuring tips from the measurement circuit.
- Remove the black and red safety measuring leads from the BENNING CM 2.
- Lay the BENNING CM 2 on its front and unscrew the screw on the cover of
the battery compartment.
- Push the cover of the battery compartment to the side out of its guide.
- Remove the discharged batteries from the battery holder.
- Insert the new batteries into the battery holder. Make sure that they are
connected to the correct battery poles.
- Push the cover of the battery compartment into its correct position and
replace the screw.
See fig. 7: Replacing the batteries.
Remember the environment! Do not dispose of used batteries
with domestic waste. Dispose of them at a battery-collection
point or as toxic waste. Your local authority will give you the
information you need.
9.4 Calibration
Benning guarantees compliance with the technical and accuracy specifications
stated in the operating manual for the first 12 months after the delivery date.
To maintain the specified precision of the measurement results, the instrument
must be recalibrated at regular intervals by our factory service. We recommend
a recalibration interval of one year. Send the appliance to the following address:
Benning Elektrotechnik & Elektronik GmbH & CO. KG
Service Centre
Robert-Bosch-Str. 20
D - 46397 Bocholt
10. Technical data of the measuring accessories
- Standard: EN 61010-031,
- Maximum rated voltage to earth (
) and measuring category:
With push-on caps: 1000 V CAT III, 600 V CAT IV,
Without push-on caps: 1000 V CAT II,
- Maximum rated current: 10 A,
- Protective class II (
), continuous double or reinforced insulation,
- Contamination class: 2,
- Length: 1.4 m, AWG 18,
- Environmental conditions:
Maximum barometric elevation for making measurements: 2000 m,
Temperatures: 0 °C to + 50 °C, humidity 50 % to 80 %
- Only use the test leads if in perfect condition and according to this manual,
since the protection provided could otherwise be impaired.
- Throw the test leads out if the insulation is damaged or if there is a break in
the cable/ plug.
- Do not touch the bare contact tips of the test leads. Only grab the area
appropriate for hands!
- Insert the angled terminals in the testing or measuring device.
11. Environmental note
At the end of the product’s useful life, please dispose of the device at
collection points provided in your community.

Chat with your Benning CM 2 manual using AI

Get instant AI answers from your Benning CM 2 manual

Ask anything about the Benning CM 2. Answers come from this manual, with the pages they are based on.

CM 2 Maintenance Schedule

Remind me when maintenance is due
Yearly
Calibrate the device at factory service

Send the unit to Benning Service Center for regular recalibration to maintain specified measurement accuracy. Recommended interval is one year.

Show in the manual (page 23)
As needed (battery symbol)
Replace batteries when low

Replace the two 1.5V batteries immediately when the battery symbol appears on the display. Ensure device is voltage-free before opening.

Show in the manual (page 22)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend CM 2?

Yes No
0
User Pic

RV_Traveler_DE

6 months ago

Does the device have a backlight for the display and is it suitable for measuring high currents in RVs?

0
User Pic

Manual.ly

6 months ago

The Benning CM2 does not feature a backlit display, which can limit readability in low-light conditions. However, it is well-suited for measuring higher currents in RVs due to its high accuracy and practical Max Hold function. Users have confirmed it effectively calibrates power displays and handles DC measurements reliably.

M: QW-35-FL
M: QW-35-FL
0
User Pic

Klaus Meier

5 months ago

Why does my new unit drain batteries quickly after shutting down automatically? Is this normal behavior?

M: QW-35-FL

Frequently Asked Questions

A

The device is rated for a maximum voltage of 600 V against earth potential in Category II and 300 V in Category III. Using it beyond these limits can compromise safety.

Is this answer helpful?

A

When using standard alkaline batteries, the Benning CM 2 offers an approximate service life of 60 hours under normal operating conditions before needing replacement.

Is this answer helpful?

A

Yes, the built-in current clamp with a Hall sensor allows you to measure AC and DC current by simply clamping around a single conductor without breaking the circuit.

Is this answer helpful?

A

Yes, the device automatically switches off after approximately 30 minutes of inactivity to conserve battery power. A beep signals when this occurs.

Is this answer helpful?

A

It is designed for Overvoltage Category II up to 600 V and Category III up to 300 V. Protective caps must be used for Category III measurements to ensure user safety.

Is this answer helpful?

A

Benning recommends calibrating the instrument every year to maintain the specified measurement accuracy and ensure compliance with technical specifications.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • True RMS technology ensures accurate readings on non-sinusoidal waveforms
  • Hall sensor current clamp allows safe, non-contact current measurement
  • Comprehensive safety compliance with CAT III and CAT IV standards
  • Auto-ranging feature eliminates the need for manual range selection
  • Built-in buzzer provides audible feedback for continuity testing
VS

Disadvantages

  • Maximum voltage limit of 600 V restricts use in high-voltage industrial circuits
  • Battery compartment requires screwdriver access for replacement
  • No backlight on the LCD display makes reading difficult in low light
  • Accuracy decreases slightly at extreme temperatures outside reference range
  • Continuity threshold varies between 50 and 300 ohms which may be inconsistent
M: QW-35-FL

Product Specification

Measurement Range

max. 300A, max. 600V, max. 40MΩ

Delivery Scope

Case, test leads, battery

M: QW-35-FL

Product Description

Benning CM 2 Current Clamp Multimeter Overview

The Benning CM 2 is a versatile digital multimeter designed for professionals who require precise measurements in various electrical environments. This True RMS device stands out as a reliable tool for measuring alternating current, AC voltage, DC current, resistance, and performing continuity tests. Its compact design and robust build make it suitable for use by qualified electricians and electrotechnically trained personnel.

Equipped with a Hall sensor-based current clamp head, the Benning CM 2 allows for non-intrusive current measurements without breaking the circuit. The device features a clear liquid crystal display that shows up to 3999 counts, ensuring high visibility of readings even in dimly lit areas. Users can easily switch between functions using a sliding switch and dedicated function buttons, which also toggle between AC/DC modes and resistance/continuity settings.

Safety is a paramount concern with this instrument. It adheres to strict safety standards including DIN VDE 0411 and EN 61010-1, allowing operation in overvoltage categories II and III with maximum voltages of 600 V and 300 V respectively. The unit includes protective caps for measurement tips to enhance user safety during category III measurements. Additionally, the multimeter automatically shuts off after approximately 30 minutes of inactivity to preserve battery life, which typically lasts around 60 hours on alkaline batteries.

The package includes two safety test leads, a protective case, and two micro-batteries. Regular calibration is recommended annually to maintain accuracy, and the device supports environmental protection through proper disposal guidelines. Whether for maintenance tasks or complex troubleshooting, the Benning CM 2 offers a balance of functionality, safety, and ease of use.