d1cf126f63b2754d310ebf5a5be61bcd0dcc page 16
03/ 2019
BENNING CM 2
16
See fig. 4: Resistance measurement
8.4 Continuity testing with buzzer
- Select the area marked with the buzzer symbol with the sliding switch
and the function button of the BENNING CM 2.
- Contact the black safety measuring lead with the COM-socket(black).
- Contact the red safety measuring lead with the V- socket (red).
- Bring the black and red measuring tips into contact with the measurement
points. If the resistance between the measurement points is less than 50 ,
the buzzer incorporated in the BENNING CM 2 sounds.
See fig. 5: Continuity testing with buzzer
8.5 Current measurement
8.5.1 Preparation for measurement
Store and use the BENNING CM 2 only under the correct temperature condi-
tions stated. Always avoid long exposure to sunlight.
- Strong sources of interference close to the BENNING CM 2 may produce
unstable readings and measurement errors.
Do not apply voltage to the output contacts of the BENNING CM 2.
If necessary, remove the safety measuring leads connected.
When measuring DC current, observe correct polarity.
8.5.2 Current measurement
- Select the desired measuring function with the sliding switch and the
function button .
- Press the “ZERO” button to set the BENNING CM 2 to the starting point.
- Operate the opening lever . Grip the single wire containing the current to
be measured with the prongs of the BENNING CM 2.
- Read the value in the digital display .
See fig. 6: AC/ DC current measurement
9. Maintenance
Before opening the BENNING CM 2, ensure that it is not
connected to a source of voltage! Electrical hazard!
Any work required on the BENNING CM 2 when it is under voltage must be
done only by a qualified electrician. Special steps must be taken to pre-
vent accidents.
Before opening the BENNING CM 2, remove it from all sources of voltage as
follows:
- Remove first the black and the red measuring tip from the measurement object.
- Then remove the black and red safety measuring leads from the BENNING CM 2.
- Move the sliding switch to the position “OFF”.
9.1 Making the unit safe
Under certain circumstances, the safety of the BENNING CM 2 can no longer
be guaranteed. This may be the case if:
- there are visible signs of damage on the unit,
- errors occur in measurements,
- the unit has been stored for a long period of time under the wrong condi-
tions, and
- if the unit has been subjected to rough handling during transport.
In these cases, the BENNING CM 2 must be switched off immediately, removed
from the measuring points and secured to prevent it from being used again.
9.2 Cleaning
Clean the outside of the unit with a clean dry cloth. (Exception: any type of
special cleaning cloth). Never use solvents or abrasives to clean the clamp
meter. Ensure that the battery compartment and the battery contacts have not
been contaminated by electrolyte leakage. If any electrolyte or white deposits
are seen in the battery compartment or battery housing, remove these with a
dry cloth.
9.3 Battery replacement
Before opening the BENNING CM 2, ensure that it is not
connected to a source of voltage! Electrical hazard!
The BENNING CM 2 is powered by two 1.5 V batteries. The batteries must be
replaced (see fig. 8) when the battery symbol appears in the display .

Chat with your Benning CM 2 manual using AI

Get instant AI answers from your Benning CM 2 manual

Ask anything about the Benning CM 2. Answers come from this manual, with the pages they are based on.

CM 2 Maintenance Schedule

Remind me when maintenance is due
Yearly
Calibrate the device at factory service

Send the unit to Benning Service Center for regular recalibration to maintain specified measurement accuracy. Recommended interval is one year.

Show in the manual (page 23)
As needed (battery symbol)
Replace batteries when low

Replace the two 1.5V batteries immediately when the battery symbol appears on the display. Ensure device is voltage-free before opening.

Show in the manual (page 22)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend CM 2?

Yes No
0
User Pic

RV_Traveler_DE

6 months ago

Does the device have a backlight for the display and is it suitable for measuring high currents in RVs?

0
User Pic

Manual.ly

6 months ago

The Benning CM2 does not feature a backlit display, which can limit readability in low-light conditions. However, it is well-suited for measuring higher currents in RVs due to its high accuracy and practical Max Hold function. Users have confirmed it effectively calibrates power displays and handles DC measurements reliably.

M: QW-35-FL
M: QW-35-FL
0
User Pic

Klaus Meier

5 months ago

Why does my new unit drain batteries quickly after shutting down automatically? Is this normal behavior?

M: QW-35-FL

Frequently Asked Questions

A

The device is rated for a maximum voltage of 600 V against earth potential in Category II and 300 V in Category III. Using it beyond these limits can compromise safety.

Is this answer helpful?

A

When using standard alkaline batteries, the Benning CM 2 offers an approximate service life of 60 hours under normal operating conditions before needing replacement.

Is this answer helpful?

A

Yes, the built-in current clamp with a Hall sensor allows you to measure AC and DC current by simply clamping around a single conductor without breaking the circuit.

Is this answer helpful?

A

Yes, the device automatically switches off after approximately 30 minutes of inactivity to conserve battery power. A beep signals when this occurs.

Is this answer helpful?

A

It is designed for Overvoltage Category II up to 600 V and Category III up to 300 V. Protective caps must be used for Category III measurements to ensure user safety.

Is this answer helpful?

A

Benning recommends calibrating the instrument every year to maintain the specified measurement accuracy and ensure compliance with technical specifications.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • True RMS technology ensures accurate readings on non-sinusoidal waveforms
  • Hall sensor current clamp allows safe, non-contact current measurement
  • Comprehensive safety compliance with CAT III and CAT IV standards
  • Auto-ranging feature eliminates the need for manual range selection
  • Built-in buzzer provides audible feedback for continuity testing
VS

Disadvantages

  • Maximum voltage limit of 600 V restricts use in high-voltage industrial circuits
  • Battery compartment requires screwdriver access for replacement
  • No backlight on the LCD display makes reading difficult in low light
  • Accuracy decreases slightly at extreme temperatures outside reference range
  • Continuity threshold varies between 50 and 300 ohms which may be inconsistent
M: QW-35-FL

Product Specification

Measurement Range

max. 300A, max. 600V, max. 40MΩ

Delivery Scope

Case, test leads, battery

M: QW-35-FL

Product Description

Benning CM 2 Current Clamp Multimeter Overview

The Benning CM 2 is a versatile digital multimeter designed for professionals who require precise measurements in various electrical environments. This True RMS device stands out as a reliable tool for measuring alternating current, AC voltage, DC current, resistance, and performing continuity tests. Its compact design and robust build make it suitable for use by qualified electricians and electrotechnically trained personnel.

Equipped with a Hall sensor-based current clamp head, the Benning CM 2 allows for non-intrusive current measurements without breaking the circuit. The device features a clear liquid crystal display that shows up to 3999 counts, ensuring high visibility of readings even in dimly lit areas. Users can easily switch between functions using a sliding switch and dedicated function buttons, which also toggle between AC/DC modes and resistance/continuity settings.

Safety is a paramount concern with this instrument. It adheres to strict safety standards including DIN VDE 0411 and EN 61010-1, allowing operation in overvoltage categories II and III with maximum voltages of 600 V and 300 V respectively. The unit includes protective caps for measurement tips to enhance user safety during category III measurements. Additionally, the multimeter automatically shuts off after approximately 30 minutes of inactivity to preserve battery life, which typically lasts around 60 hours on alkaline batteries.

The package includes two safety test leads, a protective case, and two micro-batteries. Regular calibration is recommended annually to maintain accuracy, and the device supports environmental protection through proper disposal guidelines. Whether for maintenance tasks or complex troubleshooting, the Benning CM 2 offers a balance of functionality, safety, and ease of use.