Manual.ly Logo

Benning CM 12 Manual

5.0 · 1 Ratings

PDF manual · 58 Pages

English

M: QW-35-FL
page

/ 58

Loading...
05ebe4cf77dc2a2e86b096d446346211d3e5 page 28
40
08/ 2018
BENNING CM 12
9.3 Battery replacement
Before opening the BENNING CM 12, make sure that the device
is free of voltage! Electrical danger!
The BENNING CM 12 is powered by six 1.5 V micro batteries (IEC LR03/ type
AAA). Battery replacement (see gure 11) is required as soon as all segments
of the battery symbol
L
have disappeared and the battery symbol is ashing.
Proceed as follows to replace the batteries:
- First remove the safety measuring leads from the measurement circuit.
- Remove the safety measuring leads from the BENNING CM 12.
- Turn the rotating switch
5
to “OFF”.
- Put the BENNING CM 12 face down and unscrew the four screws of the bat-
tery compartment cover.
- Lift the battery compartment cover off the bottom part.
- Remove the discharged batteries from the battery compartment.
- Insert the new batteries into the battery compartment at the provided places
(please observe correct polarity of the batteries).
- Lock the battery compartment cover into place on the bottom part and tighten
the screws.
See gure 11: Battery replacement
Remember the environment! Do not dispose of used batteries
with domestic waste. Dispose of them at a battery-collection
point or as toxic waste. Your local authority will give you the
information you need.
9.5 Calibration
Benning guarantees compliance with the technical and accuracy specications
stated in the operating manual for the rst 12 months after the delivery date.
To maintain the specied accuracy of the measurement results, the instrument
must be recalibrated at regular intervals by our factory service. We recommend
a recalibration interval of one year. Send the multimeter to the following address:
Benning Elektrotechnik & Elektronik GmbH & CO. KG
Service Centre
Robert-Bosch-Str. 20
D - 46397 Bocholt
10. Technical data of the measuring accessories
- Standard: EN 61010-031,
- Maximum rated voltage to earth () and measuring category:
With push-on caps: 1000 V CAT III, 600 V CAT IV,
Without push-on caps: 1000 V CAT II,
- Maximum rated current: 10 A,
- Protective class II (), continuous double or reinforced insulation,
- Contamination class: 2,
- Length: 1.4 m, AWG 18,
- Environmental conditions:
Maximum barometric elevation for making measurements: 2000 m,
Temperatures: 0 °C to + 50 °C, humidity 50 % to 80 %
- Only use the measuring leads if in perfect and clean condition as well as
according to this manual, since the protection provided could otherwise be
impaired.
- Throw the measuring lead out if the insulation is damaged or if there is a
break in the lead/ plug.
- Do not touch the bare contact tips of the measuring lead. Only grab the area
appropriate for hands!
- Insert the angled terminals in the testing or measuring device.
11. Environmental notice
At the end of the product’s useful life, please dispose of it at appropriate
collection points provided in your country.

Chat with your Benning CM 12 manual using AI

Get instant AI answers from your Benning CM 12 manual

Ask anything about the Benning CM 12. Answers come from this manual, with the pages they are based on.

CM 12 Maintenance Schedule

Remind me when maintenance is due
Yearly
Calibrate the device

Send the multimeter to Benning factory service for recalibration to maintain specified accuracy. Recommended interval is one year.

Show in the manual (page 40)
Regularly
Clean the housing

Wipe the outside of the unit with a clean dry cloth. Do not use solvents or abrasives. Ensure battery contacts are free from electrolyte leakage.

Show in the manual (page 40)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend CM 12?

Yes No
0
User Pic

RepudiandaeCorrupti67

5 months ago

Is the Benning current clamp suitable for electrical installations and measuring instruments?

0
User Pic

Manual.ly

5 months ago

Yes, the Benning current clamp is highly recommended for electrical installations. It provides accurate measurements and is considered a reliable tool for checking and verifying electrical systems. Many users find it essential to have this device when performing installation or maintenance tasks.

M: QW-35-FL
M: QW-35-FL
0
User Pic

Abbigail Bosco

6 months ago

Does the Benning clamp work well with other measurement tools?

M: QW-35-FL

Frequently Asked Questions

A

The device supports a maximum nominal voltage of 1000 V AC/DC in Category III and 600 V AC/DC in Category IV. Exceeding these limits can damage the unit or cause safety hazards.

Is this answer helpful?

A

Yes, it features Bluetooth Low Energy 4.0. You can download the BENNING MM-CM Link app from the App Store or Google Play to view real-time data and logs on your Android or iOS device.

Is this answer helpful?

A

Select the AC Voltage or Current function, then navigate to the THD menu using the cursor keys. Press OK to start the measurement. The device will display the total harmonic distortion percentage and individual harmonics.

Is this answer helpful?

A

No, it has an IP 30 rating which protects against solid objects larger than 2.5 mm but offers no protection against water. It is intended for dry environments only.

Is this answer helpful?

A

Benning recommends calibrating the device every year to maintain the specified accuracy. Calibration services are available through their official service center.

Is this answer helpful?

A

When the battery is depleted, all segments in the battery symbol will disappear and the symbol will flash. You must replace the six AAA batteries immediately to prevent incorrect measurements.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Supports TRUE RMS measurements for high accuracy on complex waveforms
  • Features Bluetooth Low Energy 4.0 for wireless data transmission to mobile apps
  • Includes AUTO SENSE mode to automatically select correct range and coupling
  • Capable of measuring total harmonic distortion and power factor
  • High overload protection up to 1000 V CAT III and 600 V CAT IV
VS

Disadvantages

  • Requires six AAA batteries which may need frequent replacement during heavy use
  • Non-contact voltage indicator does not confirm absence of voltage
  • Limited water resistance with only IP 30 protection rating
  • Display backlight turns off after 15 seconds if no activity occurs
  • Accuracy decreases slightly with high crest factors above 3.0
M: QW-35-FL

Product Specification

Measurement range

max. 600A, max. 1000V, max. 100kΩ

Package contents

Bag, test leads

M: QW-35-FL

Product Description

Benning CM 12 Clamp Meter Multimeter Review

The Benning CM 12 Clamp Meter Multimeter stands as a robust solution for professional electricians and technicians who require precision in complex electrical environments. This TRUE RMS digital instrument is designed to handle a wide array of measurements, from direct current and alternating voltage to resistance and capacitance. Its intelligent AUTO SENSE mode automatically detects the correct range and coupling type, streamlining the workflow for users who need quick and accurate readings without manual configuration.

Equipped with advanced features like Bluetooth connectivity, this device allows for real-time data transmission to smartphones or tablets via the BENNING MM-CM Link app. Users can log up to 9,999 measurements using the built-in data logger or store 1,000 values manually. The unit also excels in analyzing power quality, offering functions to measure total harmonic distortion (THD), power factor, and phase sequence. Whether you are troubleshooting single-phase loads or managing three-phase systems, the Benning CM 12 provides the reliability needed for CAT III 1000 V and CAT IV 600 V applications.

Safety is paramount with this tool. It features a non-contact voltage indicator and strict adherence to safety standards ensures protection against dangerous voltages. The durable design includes a large clamp opening for easy access to thick cables, and the clear LCD display with backlighting ensures readability even in dim conditions. With its comprehensive suite of measurement capabilities and wireless integration, the Benning CM 12 is an essential addition to any electrical toolkit.

Key Features

  • TRUE RMS Technology: Ensures accurate readings on non-sinusoidal waveforms.
  • Bluetooth Connectivity: Seamless data transfer to mobile devices for analysis.
  • AUTO SENSE Mode: Automatically selects the best measuring range and type.
  • Data Logging: Stores extensive measurement series for later review.
  • Phase Sequence Detection: Quickly identifies rotation direction in three-phase systems.

Important Notes

Always ensure the device is free of voltage before performing maintenance or battery replacement. Use only the provided safety leads for high-voltage measurements to maintain CAT III and CAT IV compliance. Regular calibration is recommended annually to preserve measurement accuracy.

M: QW-35-FL

© Copyright 2026 Manual.ly