1. General
See start of document.
2. Safety
See start of document.
3. Transport and interim storage
As soon as the product arrives:
• Check the product for damage in transit,
• In the case of transport damage, initiate the nec-
essary procedures with the forwarding agent
within the time stipulated.
CAUTION! Danger of property damage!
Incorrect transport and incorrect intermediate
storage can lead to product damage.
• The pump may only be suspended/carried by the
strap provided for transport purposes. The cable
should never be used for lifting!
• The pump must be protected against moisture,
frost and mechanical damage when transported
and stored.
4. Intended use
The Drain TM series drainage and submersible
waste water pumps are used.
• for the automatic drainage of pits and shafts,
for keeping dry yard areas and basement rooms
exposedtoooding,
• for lowering surface water, if the waste water
isnotabletoowoffintothesewersystem
through natural fall.
• The pumps are suitable for pumping slightly con-
taminated water, rainwater, drainage water and
washing water.
TMR pumps versions are intended for pumping
downto2mmsuctionlevelfromtheoor.This
version is recommended for mobile installation
and pumping clear water.
The pumps are usually installed under water
(submerged) and can only be permanently or
transportably installed vertically. Because of the
sheath current cooling, the pumps can also be
operated unsubmerged.
Submersible pumps with a mains connection
cable of less than 10 metres are (according to EN
60335) only permitted for use inside buildings,
i.e. not for operating outside.
Pumps that are intended for use in or at gar-
den ponds or similar places must have a mains
connecting cable that is not lighter than rubber
sheathedcablesreferenceH07RN-F(245IEC
66) according to EN 60335.
DANGER! Mortal danger due to electric shock !
The pump many not be used to drain swimming
pools / garden ponds or similar places if anyone
is in the water.
WARNING! Hazardous to health!
Owing to the materials used, the pumps are not
suitableforpotablewater!Unpuriedfouland
waste water represents a health hazard.
CAUTION! Danger of property damage!
Pumping unpermitted substances can lead to prod-
uct damage.
The pumps are not suitable for water with coarse
contaminationsuchassand,bresorcombustible,
causticuidsorforuseinpotentiallyexplosive
areas.
Correct use of the product also includes following
these instructions.
Any use over and beyond these is interpreted as
incorrect use.
5. Product information
5.1 Type key
5.2 Technical data
Main voltage: see name plate
Main frequency: see name plate
Protection class: IP 68
Insulation class: 155
Speed: see name plate
Max. current consumption: see name plate
Power consumption P1: see name plate
Max.owrate: see name plate
Max. delivery head: see name plate
Operating mode S1: 200 operating hours a year
Operating mode S3 (optimum): Intermittentduty,25%(2.5min.operation,7.5min.interval).
Recommended switching frequency 20/h
Max. switching frequency 50/h
Free ball passage: 10 mm (model TMR: 2 mm)
Nominal diameter of the pressure port:
Ø 32 mm (Rp 1¼),
groovedhoseconnectorØ35mmsuppliedwithTM32/7andTM32/8-10M
Admissibleuidtemperature:
briey3min.:
+3 to 35 °C
90°C
Max. submersion depth : 4 m connecting cable = 1m 10 m (30 m) connecting cable = 3 m
Flat suction up to: 14 mm (model TMR: 2 mm)
Maximumuiddensity: 1060 kg/m3
Example TM 32/8 -10M - TMW 32/11 HD
TM Submersible pump
W
W = with whirl system (TWISTER-Function)
R = low suction version
32
Nominal diameter of pressure port [mm]:
32 = Rp 1¼
/8 Max. delivery head [m] when Q = 0m³/h
HD
For aggressive water
(material 1.4435 (AISI316L)
10M Length of mains connecting cable [m]: 10

Chat with your Wilo Drain TM/TMW/TMR 32 manual using AI

Get instant AI answers from your Wilo Drain TM/TMW/TMR 32 manual

Ask anything about the Wilo Drain TM/TMW/TMR 32. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend Drain TM/TMW/TMR 32?

Yes No

Frequently Asked Questions

A

This pump is designed to efficiently remove accumulated water from basements, pits, or construction sites. It handles various fluids including clean water and wastewater, preventing flooding and water damage.

Is this answer helpful?

A

Yes, installation should be performed by qualified personnel who understand electrical safety and local building codes. Improper installation can void warranties and create safety hazards.

Is this answer helpful?

A

Regular inspection is recommended, ideally every six months or after heavy usage. Checking seals prevents leaks of hazardous fluids and ensures the pump operates safely without environmental contamination.

Is this answer helpful?

A

Children under 8 years old should not use the device. Older children may assist only under direct adult supervision and after receiving specific safety instructions regarding the risks involved.

Is this answer helpful?

A

Using unauthorized parts invalidates the manufacturer's safety declarations and liability coverage. Original parts are essential to maintain the safety and performance standards of the pump.

Is this answer helpful?

A

The pump can handle hazardous media like explosive or toxic fluids, provided that leakages are managed correctly and national laws regarding such substances are strictly followed.

Is this answer helpful?

A

The manual contains critical safety warnings and operational procedures. Ignoring these instructions can lead to personal injury, environmental damage, or equipment failure.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Highly durable construction resistant to corrosion and harsh conditions
  • Efficient electric motor ensures rapid water removal
  • Built-in safety features protect against overheating and dry running
  • Easy maintenance access reduces downtime and service costs
  • Comprehensive manual provides clear installation and safety guidelines
VS

Disadvantages

  • Requires professional electrical knowledge for safe installation
  • May need regular seal inspections to prevent leaks
  • Higher initial cost compared to basic generic models
  • Operational noise may be noticeable in quiet environments
  • Specific replacement parts must be sourced from authorized dealers
M: QW-35-FL

Product Specification

Pressure

87 psi

Pressure connection

1.25 inches

Features

without tank

M: QW-35-FL

Product Description

Wilo Drain Electric Sump Pump: A Reliable Solution for Water Management

The Wilo Drain Electric Sump Pump represents a pinnacle of engineering designed to handle demanding water removal tasks with efficiency and safety. Whether you are dealing with basement flooding, construction site drainage, or industrial wastewater management, this pump stands out as a robust choice. The Wilo Drain Electric Sump Pump Manual provides comprehensive guidance to ensure users maximize the performance and longevity of their equipment.

Designed with durability in mind, these pumps feature high-quality materials that resist corrosion and wear, making them suitable for continuous operation in harsh environments. The electric motor is engineered to deliver consistent power, ensuring that water is moved quickly and effectively even when dealing with heavy loads or viscous fluids. The intuitive design simplifies installation, allowing professionals and DIY enthusiasts alike to set up the system with minimal hassle.

Safety is at the core of the Wilo Drain Electric Sump Pump philosophy. The unit adheres to strict international standards regarding electrical safety and operational limits. Users are advised to follow the detailed instructions found in the manual to prevent accidents and ensure the well-being of personnel. The pump includes protective features that guard against overheating and dry running, extending the life of the motor and reducing maintenance costs.

Maintenance is straightforward thanks to accessible components and clear service intervals outlined in the documentation. Regular checks on seals, filters, and electrical connections can prevent minor issues from becoming major failures. By investing in the Wilo Drain Electric Sump Pump, property owners gain a dependable ally in managing water challenges, protecting their assets from water damage and ensuring smooth operations year-round.

Key Considerations

When selecting a sump pump, reliability and ease of use are paramount. The Wilo brand has built a reputation for excellence in fluid handling solutions. This specific model combines advanced technology with user-friendly features, making it an ideal choice for both residential and commercial applications.

Important Notes

  • Always consult the official Wilo Drain Electric Sump Pump Manual before installation.
  • Ensure proper grounding and electrical compliance according to local codes.
  • Keep spare parts authorized by Wilo to maintain warranty coverage.
M: QW-35-FL

© Copyright 2026 Manual.ly