220096babc03527c45b4c3fbdea1a67742fa page 11
15
Read these instructions and the
accompanying safety information
carefully before starting up the
device and starting work with the device.
Keep these instructions in a place that is accessible to all
users.
Safety information
Thisappliancecanbeusedby
childrenagedfrom8yearsand
above and persons with reduced
physical,sensoryormentalcapa-
bilitiesorlackofexperienceand
knowledgeiftheyhavebeengiven
supervision or instruction concer-
ning use of the appliance in a safe
wayandunderstandthehazardsin-
volved.Childrenshallnotplaywith
the appliance.
Cleaningandusermaintenance
shallnotbemadebychildrenwit-
hout supervision.
WARNING
Electrical shock
If the device is faulty, active electrical conduc-
tors may be bare or the PE conductor may not be
functional.
RepairsmustalwaysbereferredtoaWeller-trained
specialist.
‚Iftheelectricaltool‘‘spowersupplycordisdamaged,this
mustbereplacedwithaspeciallyprefabricatedpower
supplycordavailablethroughthecustomerservice
organisation.‘
WARNING
Danger of injury
Thedeviceorpartsofthedevicemayfalloffduring
transportation.
WARNING
Danger of asphyxiation, Danger of
poisoning
Improper installation can result in above-normal
workplace concentrations
Measure the workplace concentration upon completion
of installation work
Inappropriate maintenance cycles for gas media
may result in above-normal workplace concentra-
tions
Specifymaintenancecycle
Above-normal contamination levels in the ambient
air during cleaning work on the pipe system/extrac-
tion area
Ifsuctioncapacityisimpairedbybuild-upwithinthe
pipesystem,replacethecontaminatedparts
A saturated activated carbon lter will not be able
to capture harmful substances. The harmful subs-
tances will be released back into the environment
unltered.
Observetherecommendedlterreplacement
intervals.
High concentrations of harmful gases can lead to
overheating of the activated carbon and possibly
trigger spontaneous combustion of the lter.
Run the unit on clean air for several minutes before
switching off.
Specied Conditions Of Use
Thisltrationsystemissuitablefortheextractionand
ltrationofparticlesandgases,dependingonthelter
medium used.
Thisdevicemayonlybeusedatroomtemperature
and indoors.
Theunitisdesignedforuseasasurfaceextraction
unitandisnotsuitableforextractingfumesdirectly
from the soldering gun.
Soldering or welding enamelled wire
Forsolderingandweldingenamelledwire,usethe
standardprelterF7.
Extractionofadhesivevapours
Useabroadbandgaslter(withoutasuspended
matterlter)fortheextractionofadhesivevapours.
WARNING
Danger of asphyxiation, Danger of
poisoning
Improperusemayresultinrespiratoryproblems,
asphyxiation,poisoningorcancer
Particlesandgaseswhichareunsuitableforthelter
mediuminusemaynotbeextracted.
Liquidsandammablegasesmaynotbeextracted
Neverusethedevicewithoutalterorwithafulllter.
Never use the device without the fan cover
GB
ENGLISH

Chat with your Weller Zero Smog TL manual using AI

Get instant AI answers from your Weller Zero Smog TL manual

Ask anything about the Weller Zero Smog TL. Answers come from this manual, with the pages they are based on.

Zero Smog TL Maintenance Schedule

Remind me when maintenance is due
Yearly
Replace the compact filter

The compact filter must be replaced at least once a year to ensure proper function. Also replace if workplace concentration limits are exceeded.

Show in the manual (page 14)
Every 10 pre-filter changes
Replace compact filter after 10 pre-filters

It is strongly recommended to replace the compact filter after no more than 10 changes of the fine dust pre-filter.

Show in the manual (page 14)
Regularly
Clean nozzle, arm and hose

To ensure proper function, clean the nozzle, extractor arm and connecting hose on a regular basis.

Show in the manual (page 15)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend Zero Smog TL?

Yes No

Frequently Asked Questions

A

It is designed to extract and filter particles and gases from compatible indoor soldering processes. Filtration performance depends on the filter medium installed and the contaminants present.

Is this answer helpful?

A

No. The unit is designed as a surface extraction system and is not intended for direct fume extraction at the soldering iron.

Is this answer helpful?

A

The system uses an F7 prefilter and a compact main filter that combines H13 high-efficiency particle filtration with activated carbon.

Is this answer helpful?

A

Replace the compact filter at least once per year, according to the maintenance plan, or sooner if required by workplace conditions. Replace the fine-dust prefilter more frequently, and consider replacing the compact filter after no more than 10 prefilter changes.

Is this answer helpful?

A

A flashing yellow light with an alarm indicates the recommended filter service life has expired. A steady red light with an alarm indicates low extraction capacity and requires inspection of the airflow path and possibly filter replacement.

Is this answer helpful?

A

Switch off the unit, inspect and clean the nozzle, hoses, pipes, and extraction arm, and check for leaks. If the alarm returns after restarting, replace the filter.

Is this answer helpful?

A

No. Do not use the extractor for liquids or flammable gases. It must also not be exposed to open flames, condensed solvents, or temperatures above 50 C.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • Staged filtration combines an F7 prefilter, H13 particle filtration, and activated carbon.
  • Maximum airflow of 190 m3/h supports surface-level solder fume extraction.
  • Filter-life and extraction-capacity alerts help identify required maintenance.
  • Compact 335 x 330 x 445 mm design and ESD-compatible construction suit electronics workstations.
  • Automatic shutdown after persistent low airflow helps limit overheating.
VS

Disadvantages

  • Designed for surface extraction, not direct extraction at the soldering iron.
  • Requires regular prefilter changes and compact-filter replacement at least annually.
  • Not suitable for liquids, flammable gases, temperatures above 50 C, or outdoor operation.
  • Filter suitability depends on the contaminants being extracted and the installed filter medium.
  • Contaminated replacement filters must be handled as special waste.
M: gpt-5.6-terra

Product Description

Weller FT91015699N Zero Smog TL Kit 1 FN Solder Fume Extractor - Read, Download & Print Free

The Weller FT91015699N Zero Smog TL Kit 1 FN Solder Fume Extractor is designed to support cleaner indoor soldering work through surface-level fume extraction. Built for electronics benches, repair stations, and production environments, it helps capture airborne particles and gases generated during compatible soldering processes. Its compact footprint makes it practical where workspace is limited, while its ESD-compatible design suits sensitive electronic assemblies.

Filtration and airflow performance

The Zero Smog TL uses a staged filtration approach. An F7 prefilter captures a portion of larger fine dust before the air reaches the compact main filter. The main filter combines an H13 high-efficiency particle filter with activated carbon, helping address both particulate contamination and selected gas-phase pollutants. The unit offers a maximum airflow of 190 m3/h and a maximum vacuum of 3000 Pa, providing the capacity needed for properly arranged surface extraction setups.

At approximately 53 dB(A) measured from one meter away, the extractor is intended to balance workstation performance with a manageable operating sound level. The housing measures 335 x 330 x 445 mm and weighs about 9 kg, making it a relatively compact unit for fixed bench placement. A 2.5 L gas filter capacity supports the activated-carbon stage.

Monitoring and routine maintenance

Filter status indicators help users monitor operating time and extraction capacity. A yellow warning light and audible alarm indicate that the recommended filter service life has elapsed. A continuous red warning light and alarm indicate low extraction performance, prompting users to inspect nozzles, hoses, and extraction arms for blockage or contamination. If the issue continues after cleaning, the filter should be replaced.

The fine-dust prefilter requires more frequent replacement than the compact main filter. The compact filter should be changed at least once yearly, according to the maintenance plan, or sooner when workplace exposure limits are exceeded. The system also includes a filter-time reset procedure after a main-filter replacement.

Important use notes

This extractor is intended for indoor use at room temperature and as a surface extraction system. It is not intended for direct extraction at the soldering iron. Never use it without filters, with saturated filters, or for liquids and flammable gases. For adhesive vapors, a compatible broadband gas filter without a suspended-particle filter is specified. Run the unit with clean air for several minutes before shutdown when processing harmful gases to reduce heat buildup in the activated carbon.

Note: Regular cleaning of the nozzle, extraction arm, and connecting hose supports reliable airflow. Contaminated filters require disposal as special waste according to local regulations.