OPERATING INSTRUCTIONS
VERSION 10/19
VOLTAGE TESTER “VC-65”
ITEM NO.: 1377526
INTENDED USE
The two-pole voltage tester can be used to measure and display DC and AC voltages in an electrical
low-voltage circuit. The product also has an acoustic and visual circuit indicator as well as a resistance
measurement and an RCD test function. Power is supplied by two batteries of type
AAA/Micro included in the delivery.
The voltage tester complies with the standard for two-pole voltage testers of 12 - 1000 V/AC and
12 - 1200 V/DC, CAT III 1000 V, CAT IV 600 V according to EN 61243-3:2014/EN 60529 as well as
protection class IP64 (dust and spray water). The product is suitable for use in dry or damp conditions.
Use during rain or other precipitation is not permitted. The voltage tester is designed for use by electrically
skilled persons using personal protective equipment.
The measuring instrument must not be operated when the battery compartment is open.
Measuringunderadverseambientconditionssuchasdustandammablegases,vapoursorsolventsis
not permitted.
Always observe the safety instructions and all other information included in these operating instructions.
This product complies with the applicable national and European requirements. All names of companies
and products are the trademarks of the respective owners. All rights reserved.
DELIVERY CONTENT
• Voltage tester
• 2x batteries of type Micro/AAA
• 2x protective plastic covers
• 2x 4 mm adapter to open probe tips
• Operating instructions
Up-to-date operating instructions
Download the latest operating instructions via the link www.conrad.com/downloads or scan the QR code.
Follow the instructions on the website.
EXPLANATION OF SYMBOLS
Thelighteningashsymbolinatrianglewarnsagainsttheriskofanelectricshockor
interference with the electrical safety of the device.
An exclamation mark inside a triangle refers to important. notes in the operating instructions.
The arrow symbol indicates special information and advice on operating the device.
SAFETY INSTRUCTIONS
The warranty will expire in case of any damage caused by the failure to follow these
operating instructions! We assume no liability for any resulting consequential damage!
We assume no liability for any damage to property or personal injuries caused by
improper use or non-compliance with the safety instructions! In such cases, the warranty
will be null and void.
• Theunauthorisedconversionand/ormodicationoftheproductisnotpermittedforsafetyand
approval reasons (CE). Do not disassemble the product.
• This product is not a toy. Therefore, be especially careful when children are around. Use the
product where it is out of the reach of children.
• Never use the product immediately after it has been taken from a cold room to a warm one.
The condensation that forms can ruin the product under certain circumstances.
• Avoid the following adverse conditions at the location of installation and during transport:
- Extreme cold or heat, direct sunlight
-Dustorammablegases,fumesorsolvents
- Strong impacts, blows
• Do not leave packaging material carelessly lying around, since it could become a dangerous
plaything for children.
• Handletheproductwithcare,itcanbedamagedbyimpacts,blows,oraccidentalfalls,even
from a low height.
• Never touch the measuring tips or a measuring point during the measuring process. There is
a risk of electric shock.
• Never touch areas outside of the marked handling area during a measurement.
• Donotuseintheimmediateproximityofstrongmagneticorelectromagneticeldsor
transmission aerials. These can affect the measurement.
• Prior to and after each measurement, check your instrument and the measuring leads for
damages. Never take any measurements if the protecting insulation is defective or the
measuring instrument is damaged otherwise.
• Be especially careful when dealing with voltages higher than 50 V/AC or 75 V/DC. Even at
such voltages you can get a life-threatening electric shock if you come into contact with live
electric wires.
• The measuring instrument is suitable for use in dry or damp conditions. Avoid use in a damp
or wet environment. Always ensure that the probe tips are perfectly clean. Dirty or even
corroded test clips can lead to an incorrect measurement.
• The test probes must only be touched at the handles provided for this purpose. Otherwise,
there is danger of an electric shock.
• Never exceed the highest permissible voltage values. If the stated values are exceeded, the
product becomes damaged and poses a hazard that can be fatal. (See chapter “Technical
data”).
• Therecoverytimeasspeciedin“Technicaldata”mustalwaysbeadheredto.Otherwise,the
product could be damaged.
• Thevoltagevaluesspeciedarenominalvoltages.
• If the neutral wire (N) or the earth wire (PE) is interrupted, no reading is shown.
• The measuring instrument must only be used within the permissible ambient conditions (see
chapter “Technical data”).
• Always attach the measuring tip cover if you are no longer using the device.
• Store the measuring instrument in a dry place, protected against dust, if you are no longer
using it.
• When using the voltage tester in the measurement category CAT III and CAT IV, it is
recommended to attach the plastic protective covers to the test probes to decrease the length
of the free contact tips. This reduces the risk of a possible short circuit during testing.
• Depending on the internal impedance of the voltage tester, there are different ways of
displaying “operating voltage present” or “operating voltage not present” in the presence of
interference voltage.
• A voltage tester with relatively low internal impedance does not display all interference
voltageswithaninitialvalueaboveELV,comparedtothereferencevalueof100kΩ.Upon
contact with the parts to be tested, the voltage tester may temporarily reduce the interference
voltage by discharging to a level below ELV; however, after removing the voltage detector, the
interference voltage will assume its original value again.
• Whenthenotication“voltagepresent”doesnotappear,itisstronglyrecommendedthatyou
insert the earthing device before starting work.
• A voltage tester with relatively high internal impedance will not clearly display “operating
voltage present” in the event of existing interference voltage, compared to the reference value
of100kΩ.
• When “voltage present” appears on a part which is considered disconnected from the system,
it is strongly recommended to check the state “operating voltage not present” with additional
measures (e.g., using a suitable voltage tester, visual inspection of the disconnection point
in the electrical network, etc.) to make sure the voltage indicated by the voltage tester is not
a fault.
• A voltage tester indicating two values of the internal impedance has passed the design test
for handling interference voltages and is able to differentiate (within technical limits) the
operating voltage from the interference voltage and directly or indirectly display the existing
voltage type.
• CAT I Measurement category I for measuring electrical and electronic devices that are
not directly supplied with mains voltage (e.g. battery-operated devices, etc.)
• CAT II Measurement category II for measuring electrical and electronic devices that are
directly supplied with mains voltage via a mains plug.
• CAT III Measurement category III for measuring building installations (e.g. mains sockets
or sub-distributors).
• CAT IV Measurement category IV for measuring the source of low-voltage installations
(e.g. main distribution, main transfer point of the utility company) and outdoors.
GENERAL BATTERY INSTRUCTIONS
• Batteries should be kept out of the reach of children.
• Do not leave batteries lying around in the open; there is a risk of them being swallowed by children or
pets. If they are swallowed, consult a doctor immediately.
• Leaking or damaged batteries can lead to caustic burning of the skin. Therefore, use suitable protective
gloves.
• Batteriesmustnotbeshort-circuited,openedorthrownintore.Thereisariskofexplosion.
• Makesurethatthepolarityiscorrectwheninsertingthebatteries(payattentiontoplus/+andminus/–).

Chat with your Voltcraft VC-65 manual using AI

Get instant AI answers from your Voltcraft VC-65 manual

Ask anything about the Voltcraft VC-65. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend VC-65?

Yes No
0
User Pic

RepellendusDolorum70

6 months ago

Does the device indicate when the load function is active and voltage is present, or does it behave like a normal measurement?

0
User Pic

Manual.ly

6 months ago

The device provides visual and acoustic feedback during phase detection. However, for the load function specifically, please ensure that both the probe and the reference point are correctly connected to complete the circuit. If the vibration or buzzer does not activate, verify that the measured voltage exceeds the minimum threshold of approximately 9V and that the load resistor is properly engaged.

M: QW-35-FL
M: QW-35-FL
0
User Pic

Jennifer Kennedy

5 months ago

Is this multimeter suitable for professional use or just hobby projects compared to US products?

M: QW-35-FL

Frequently Asked Questions

A

No, the manual strictly prohibits the use of rechargeable batteries. You must use standard alkaline AAA/Micro batteries to ensure proper operation and safety.

Is this answer helpful?

A

CAT III is for building installations like sockets, while CAT IV is for the source of low-voltage installations like main distribution boards. The VC65 supports both categories safely within its voltage limits.

Is this answer helpful?

A

It has limited functionality without batteries. The dangerous voltage warning LED will still activate at 50V AC or 120V DC, but no other measurements or displays will function.

Is this answer helpful?

A

Hold both measuring tips together. If the device works, you will hear a signal tone and see the continuity symbol light up on the display.

Is this answer helpful?

A

It is splash-proof with an IP64 rating, meaning it resists dust and water jets. However, it should never be operated during rain or submerged in water.

Is this answer helpful?

A

Yes, for AC voltages of 100V or higher, the LCD display shows the phase rotation direction as either L or R.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Measures AC and DC voltages up to 1200V with high precision
  • Includes RCD, continuity, and resistance testing capabilities
  • IP64 rated for protection against dust and water splashes
  • Auto-power-on feature saves battery life effectively
  • Built-in LED light aids visibility in dark workspaces
VS

Disadvantages

  • Rechargeable batteries are explicitly not allowed for use
  • Cannot determine specific tripping current or time for RCD tests
  • Single-pole mode cannot verify absence of voltage alone
  • Requires annual calibration to ensure long-term accuracy
  • Probe covers may slightly reduce reach in tight spaces
M: QW-35-FL

Product Specification

Measurement range

12-1200V

M: QW-35-FL

Product Description

Voltcraft VC65 Voltage Tester - Read, Download & Print Free

The Voltcraft VC65 Voltage Tester is a robust and versatile tool designed for electricians and technicians who require precise measurements in low-voltage circuits. This two-pole device excels at measuring both alternating and direct currents, offering a wide voltage range from 12 to 1000 V AC and up to 1200 V DC. It adheres to strict safety standards, including CAT III 1000 V and CAT IV 600 V classifications, ensuring reliable performance even in demanding environments.

Beyond simple voltage detection, the VC65 integrates multiple diagnostic functions. Users can perform continuity checks with audible and visual feedback, measure electrical resistance up to 1999 Ohms, and test Residual Current Devices (RCDs) to verify safety mechanisms. The device features an automatic power-on function that activates when voltage is detected above 12 V, conserving battery life during idle periods. A clear LCD display provides real-time data, including phase rotation direction for three-phase systems and a bar graph indicating the measurement range.

Safety is paramount with this instrument. It carries an IP64 rating, making it resistant to dust and water splashes, suitable for both dry and damp conditions, though it must not be used in rain. The unit includes protective plastic covers for the probes to minimize short-circuit risks during high-category testing. Additionally, a built-in LED light illuminates the measurement point in low-light scenarios, and a hold function allows users to freeze readings for easier analysis. The tester runs on two standard AAA batteries, which are included in the package along with necessary adapters and a durable carrying case design.

Important Usage Notes

  • Always perform a functional self-test before every use by touching the probe tips together.
  • Never exceed the maximum voltage limits specified in the technical data to prevent fatal injury or device damage.
  • Ensure the battery compartment is fully closed during operation to maintain safety integrity.
  • Use alkaline batteries only; rechargeable batteries are not permitted for this model.
  • Calibrate the device annually to maintain measurement accuracy over time.