c) Connection to a Direct Voltage Source
• Donotwearanymetalorconductivematerials,suchasjewellery(necklaces,bracelets,rings,etc.).A
shortcircuitattherechargeablebatteryorinvertercausesadangerofinjury,reandexplosion.
• Foraconverterwithpoleterminals,asuitableconnectioncablewithasufcientlylargelinecross-sec-
tionmustbeused(seechapter"TechnicalData").Thelongertheconnectioncable,thelargertheline
cross-section has to be. If the line cross-section is too small, the connection cable may grow hot. There
isadangerofre!Keeptheconnectioncablebetweentheconverterandtherechargeablebatteryas
short as possible for this reason.
Very strong overheating may also cause a defect to the insulation of the connection cable, which may
causeshortcircuit.Thereisariskofexplosionoftherechargeablebattery,aswellasdangerofre!
Aconverterwithpoleterminalsshouldneverbedirectlyconnectedtoadirectvoltagesource(e.g.acar
battery), but only via an accordingly sized fuse. This fuse should be placed as close as possible to the
direct voltage source.
• Ataconverterwithcigarettelighterplug(types"SW-100"and"SW-150"),theconnectioncablemust
not be cut off, shortened or extended.
• Beforetheinverterisconnectedtothedirectvoltagesource,itmustbeswitchedoff.
• Alwaysobservethecorrectpolarity(plus/+andminus/-)forconnectionoftheconverter.
• Dependingonthepowertakenfromtheinverter,thedirectvoltagesource(e.g.acarbattery)mustbe
able to supply the corresponding current strength.
 • Checkallconnectionsfortighttandgoodelectricalcontactatregularintervals.Hightransferresist-
ancesnotonlyreducetheperformanceoftheinverterbutalsomaycauseoverheatingandre.
• Theinvertermustnotbeconnectedtoelectricalsystems(e.g.amotorvehicle)wherethepluspoleis
grounded or connected to the chassis of the vehicle.
d) Mains Voltage Output
• Donotpullthemainsplugfromthemainssocketoftheinverterbypullingthecable.
• Neverconnecttheoutputoftheinvertertoanother230Vsource(e.g.amainssocket).Theinverter
must not be used to feed mains voltage into an electrical building installation.
• Inthedeactivatedcondition,thechargedcapacitorsmaystillcausethealternatingvoltagetobe
pending at the mains sockets of the converter.
e) Operation
• Donotoperatetheinverterunsupervised.
• Nevertouchtheblanklivecontactsorconnectionterminalsontheinputsideoftheconverter.
• Evenaftertriggeringtheinternalprotectivedeviceordeviceprotection,partsoftheconvertermaystill
be live!
• Thehousingoftheinverterwillheatupinoperation(dependingontheoutput).Therefore,always
observesufcientventilationoftheinverter;nevercoveritinoperation.Neverclosetheventilationslots
of the inverter.
Keep a minimum distance of 10 cm from other devices around the housing of the inverter.

Chat with your Voltcraft SW manual using AI

Get instant AI answers from your Voltcraft SW manual

Ask anything about the Voltcraft SW. Answers come from this manual, with the pages they are based on.

SW Maintenance Schedule

As needed
Replace blown fuse

If the fuse trips, switch off the inverter, disconnect consumers, remove the cause, and replace with an identical rated current fuse. Never bridge a defective fuse.

Show in the manual (page 34)
Regular intervals
Check connection tightness

Check all connections for tight fit and good electrical contact at regular intervals to prevent overheating and fire due to high transfer resistances.

Show in the manual (page 27)
As needed
Clean housing and vents

Switch off and disconnect before cleaning. Use only a soft, dry, lint-free cloth or a clean brush/vacuum for dust. Do not use cleaning agents.

Show in the manual (page 34)
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend SW?

Yes No

Frequently Asked Questions

A

Yes, provided the inverter's peak power rating exceeds the refrigerator's startup surge, which is often ten times its rated power. For example, a 50W fridge may need 500W momentarily.

Is this answer helpful?

A

The inverter will first blink red to warn you. If voltage continues to drop below the threshold, it will automatically shut off the output to prevent damaging the battery through deep discharge.

Is this answer helpful?

A

Yes, especially for models with pole terminals. A fuse must be placed close to the battery source to protect against fire and explosion risks caused by short circuits.

Is this answer helpful?

A

No, the instructions explicitly state not to operate the inverter unsupervised due to potential overheating or electrical faults that could lead to fire hazards.

Is this answer helpful?

A

No, the SW-100 and SW-150 models with cigarette lighter plugs do not have a remote control input port. Only larger models with pole terminals support remote switching.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • True sine wave output compatible with sensitive electronics
  • Multiple power ratings from 100W to 4000W for diverse needs
  • Comprehensive safety protections against overload and short circuits
  • Clear LED status indicators for easy monitoring
  • Soft-start function handles motor startup surges effectively
VS

Disadvantages

  • Requires careful selection of battery capacity and cable thickness
  • Housing generates significant heat requiring adequate ventilation
  • Not suitable for tropical climates or outdoor wet environments
  • Some high-power models require complex wiring and fusing
  • Cannot be used directly with positive-grounded vehicle electrical systems
M: QW-35-FL

Product Specification

Output Voltage

230V AC Sine Wave

Inputs

1x Terminal Block

Outputs

1x IEC C13 Outlet, 1x Euro Outlet

Average Efficiency

>88%

M: QW-35-FL

Product Description

Voltcraft SW Inverter Series: Reliable Power Conversion for Any Need

The Voltcraft Wechselrichter SW series represents a robust solution for converting direct current into high-quality alternating current. Designed for both hobbyists and professionals, these inverters transform DC voltage from batteries - available in 12V or 24V configurations - into a stable 225V AC output at 50Hz. This true sine wave technology ensures compatibility with sensitive electronics that might struggle with modified sine waves, making it ideal for powering tools, medical devices (with caution), and household appliances off-grid.

Available in various power ratings ranging from 100W to 4000W, the SW series offers versatility for different applications. Smaller models like the SW-100 and SW-150 feature convenient cigarette lighter plugs for mobile use in vehicles, while higher-power units utilize heavy-duty pole terminals for permanent installations in caravans, boats, or solar systems. Each unit is equipped with essential safety features including overload protection, short-circuit prevention, polarity reversal safeguards, and thermal shutdown mechanisms to ensure long-term reliability.

Operation is straightforward thanks to clear LED indicators that display status conditions such as normal operation, low battery warnings, or fault states. The devices include soft-start functions to handle the initial surge of motors and compressors without tripping the system. Proper ventilation is critical during operation, as the housing can become warm under load. Users must adhere to strict installation guidelines, ensuring the device remains dry, free from flammable materials, and securely mounted to prevent movement or damage.

Whether you need a compact unit for camping or a powerful inverter for a home backup system, the Voltcraft SW series delivers consistent performance with an excellent price-to-performance ratio. Always consult the technical specifications for recommended battery capacities and cable cross-sections to maximize efficiency and safety.

M: QW-35-FL

© Copyright 2026 Manual.ly