Manual.ly Logo

Voltcraft SMA-10 Manual

4.5 · 2 Ratings

PDF manual · 4 Pages

English

M: OA-GPT-54-NAN
page

/ 4

Loading...
b2fbaa14d0a5ced096c716f85d559802d78d page 2
3. Power 4. Earth leakage current
5. Insulation 6. Connections
DISPOSAL7.
Electronic devices are recyclable waste and must not be disposed of in the household waste.
At the end of its service life, dispose of the product according to the relevant statutory
regulations.
TECHNICAL DATA8.
Measurement adapter
Nominal voltage: 230 V/AC, 50 Hz, 10 A
Operating temperature: +5 ºC to +40 ºC
Operating humidity: max. 80 %
Operating altitude: max. 2000 m
Dimensions (W x H x D): 111 x 53 x 67 mm
Weight: 350 g
Consumer
Nominal current: 10 A
Max. power: 2300 W
OPERATING INSTRUCTIONS
Version 11/11
SMA-10 MEASUREMENT ADAPTER
Item No. 12 39 80
INTENDED USE1.
This product is designed to check electrical consumers for the following parameters, using an optional measuring
instrument: electric current, voltage, power output, earth leakage current, insulation and connections. The
housing of the consumer to be measured does not have to be opened to perform the measurement. This
product shall only be operated by qualifi ed specialists. The product is powered by line voltage of 230 V/AC,
50 Hz.
Do not operate the measurement adapter when the cabinet is open. Do not perform measurements in humid
premises or outdoors and avoid unfavourable ambient conditions.
Unfavourable ambient conditions are for example:
moisture and high air humidity•
dust and combustible gases, vapours or solvents,•
strong vibrations,•
strong magnetic fi elds as existing in the vicinity of machines and speakers,•
thunderstorms or similar conditions such as strong electrostatic fi elds, etc.•
Unauthorised conversion and/or modifi cation of the device are inadmissible because of safety and approval
reasons (CE). Any usage other than described above is not permitted and can damage the product and lead to
associated risks such as short-circuit, fi re, electric shock, etc. Please read the operating instructions thoroughly
and keep them for further reference.
CONTENT OF DELIVERY2.
Measurement adapter•
3 x Measuring bridges•
Operating instructions•
SAFETY INSTRUCTIONS3.
We do not assume liability for resulting damages to property or personal injury if the
product has been abused in any way or damaged by improper use or failure to observe
these operating instructions. The warranty/ guarantee will then expire!
The icon with exclamation mark indicates important information in the operating
instructions. Carefully read the whole operating instructions before operating the device,
otherwise there is risk of danger.
Personal safety
Products operated using the mains voltage must be kept out of the reach of children. For this reason, be •
particularly careful when using the product in the presence of children. They may try to stick objects into the
device through openings in the housing. This poses a risk of death by electric shock.
Never pour liquids over electrical appliances and never leave objects fi lled with liquids (e.g. vases) on it or •
in the vicinity. There is a high risk of fi re or life-threatening electric shock.
Operate the product in dry interior spaces only. It must not get damp or wet. Otherwise there is a risk of a •
life-threatening electric shock!
In schools, training facilities, hobby or self-service workshops, handling of electrical devices must be •
monitored by trained personnel.
When operating on commercial premises, the relevant accident prevention regulations of workers’ •
compensation boards for electrical equipment must be observed.
Always lay the cables so that nobody can trip over or become entangled in them. This poses a risk of •
injury.
If you have reason to assume that safe operation is no longer ensured, switch the device off and secure it so •
that it cannot be operated accidentally. Safe operation is no longer ensured under the following conditions:
The device has visible damages or is no longer working. -
The power cable or the plug is worn out or otherwise damaged. -
The internal fuse is defective. In this case, have the fuse replaced by a specialist. -
The device was stored for a longer period of time under unfavourable conditions. -
The device was exposed to heavy strain during transport. -
Product safety
Check the product for damage(s) each time before use. If you discover any damages, do not use the •
product. Disconnect the power supply and unplug the mains adapter from the wall outlet. Then bring the
product to a specialised workshop.
Use only a proper mains socket (230 V~ / 50Hz) connected to the public power supply. •
Do not pull the mains adapter out of the wall outlet by its cable!•
The plug must be pulled out of the socket under the following conditions:•
before cleaning the product -
during a thunder storm -
if the product is not being used over a long period. -
When used in conjunction with other devices, observe the operating instructions and safety notices of •
connected devices.
The product must not be subjected to heavy mechanical stress.•
The product must not be exposed it to extreme temperatures, direct sunlight, intense vibration, or •
dampness.
Miscellaneous
Repair works must only be carried out by a specialist/ specialist workshop.•
If you have queries about handling the device, that are not answered in this operating instruction, our •
technical support is available under the following address and telephone number: Voltcraft
®
, 92242
Hirschau, Lindenweg 15, Germany, phone 0180 / 586 582 7
OPERATING ELEMENTS4.
1
2
3
4
1. Power plug
2. Measuring bridges
3. Terminals PE, N and L (top down)
4. Outlet for connecting the consumer
CIRCUIT DIAGRAM5.
L
L
N
N
OPERATION6.
Insert the three measuring bridges into the measurement adapter’s terminals PE, N and L.1.
Connect the measurement adapter’s mains plug to a suitable mains outlet.2.
Connect the electrical consumer’s mains plug to the outlet of the measurement adapter.3.
Switch the electrical consumer on.4.
Note the following circuit diagrams for the correct positioning of your measuring instrument’s test prods and 5.
the correct use of the measuring bridges for each different type of measurement.
Note that for current measurements, the measuring bridge has to be removed and the measuring
instrument has to be connected in series.
An insulation tester is available at Item No. 101015. For other types of measurement, a diverse
range of Voltcraft measuring instruments is available.
1. Current 2. Voltage
These operating instructions are published by Voltcraft®,
Lindenweg 15, D-92242 Hirschau/ Germany, Phone +49 180 586 582 7.
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfi lming, or the
capture in electronic data processing systems require the prior written approval by the editor. Reprinting,
also in part, is prohibited.
The operating instructions refl ect the current technical specifi cations at time of print.
We reserve the right to change the technical or physical specifi cations.
© Copyright 2011 by Voltcraft®.
V2_1111_02-SB

Chat with your Voltcraft SMA-10 manual using AI

Get instant AI answers from your Voltcraft SMA-10 manual

Ask anything about the Voltcraft SMA-10. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend SMA-10?

Yes No
0
User Pic

Finn Schwab

7 months ago

Can I measure with a current clamp using this device, or does it only work with the included plug bridges? I want to avoid unsafe wiring mistakes.

0
User Pic

Manual.ly

7 months ago

The included plug bridges are designed for the intended connection layout, so a direct measurement with a current clamp is not possible through the bridge sockets. For current measurements, you typically use a short, suitable measuring lead connected to the corresponding jack(s). If you plan to connect other cables, make sure they use matching, properly insulated plugs and that the wiring matches your circuit (to prevent short circuits and exposure of live conductors). When in doubt, follow the VDE0100 test procedure and verify the correct pairing of jacks before applying power. Using the supplied bridges reduces the risk of misconnection.

M: OA-GPT-54-NAN
M: OA-GPT-54-NAN

Frequently Asked Questions

A

It is designed to verify electrical consumers using optional measuring instruments for current, voltage, power output, earth leakage current, insulation, and connection assignment.

Is this answer helpful?

A

No. The measurement concept allows checking the connected consumer without opening its housing, as long as you use the correct adapter connections and compatible measuring equipment.

Is this answer helpful?

A

The adapter is powered by 230 V AC at 50 Hz. It is rated for 10 A consumer connection current and supports up to 2300 W maximum power for the connected consumer.

Is this answer helpful?

A

Only in dry interior locations. Measurements are not allowed in humid premises or outdoors, and unfavourable conditions such as moisture, excessive dust, combustible vapours, strong vibrations, and strong magnetic fields should be avoided.

Is this answer helpful?

A

Insert the three supplied measuring bridges into terminals PE, N, and L. Connect the adapter to a suitable 230 V AC mains outlet. Then plug the consumer into the adapter outlet, switch the consumer on, and follow the relevant measurement diagram.

Is this answer helpful?

A

Yes. For current measurements, the measuring bridge must be removed and your measuring instrument has to be connected in series with the consumer.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • Multifunction checks: current, voltage, power, earth leakage current, insulation, and connection assignment.
  • No need to open the consumer housing, simplifying verification for many appliances.
  • Includes 3 measuring bridges to set up PE, N, and L connection quickly.
  • Rated for 10 A and up to 2300 W, supporting a wide range of consumer testing.
  • Clear measurement guidance, including probe positioning and current-measurement handling notes.
VS

Disadvantages

  • Not permitted in humid rooms or outdoors, limiting use to dry indoor environments.
  • For safety, it must not be used when the adapter cabinet is open.
  • Requires a qualified specialist and compatible optional measuring instruments.
  • Current measurement needs special setup (bridge removed, instrument connected in series).
  • Unauthorized modifications are explicitly disallowed, which can restrict customization.
M: OA-GPT-54-NAN

Product Description

Voltcraft SMA-10 Socket Tester (Socket Tester with Measurement Adapter)

The Voltcraft SMA-10 Socket Tester is a practical measurement adapter designed for checking key electrical parameters of everyday consumers without having to open their housings. Powered from 230 V AC (50 Hz), it lets you evaluate common values such as current, voltage, power, earth leakage current, insulation, and connection assignment. In short, it is built to help you verify whether a connected device behaves as expected, using compatible measuring instruments.

What makes the Voltcraft SMA-10 stand out is its straightforward workflow: you connect the three supplied measuring bridges to the PE, N, and L terminals on the adapter, then plug the adapter into a suitable mains socket. Finally, you connect the consumer to the adapter outlet, switch the consumer on, and perform the appropriate measurements with your test equipment. The Voltcraft SMA-10 Socket Tester Manual is especially useful here, because it clarifies how to position probes and how different bridge usage applies to different measurement types.

Technical highlights at a glance

  • Nominal supply: 230 V AC, 50 Hz
  • Measurement adapter rated current: 10 A
  • Maximum power: 2300 W (for the consumer connection)
  • Operating temperature: +5 C to +40 C
  • Intended environment: dry indoor use, up to 2000 m altitude

Safety-first approach

This adapter must not be operated when its cabinet is open, and measurements are not permitted in humid rooms or outdoors. The instructions also emphasize qualified specialist use, and warn against unauthorized modifications. Before each use, check for visible damage, ensure you use only a proper mains socket, and avoid mechanical stress or extreme environmental conditions.

Key results

  • Checks multiple consumer parameters: current, voltage, power, earth leakage current, insulation, and connection assignment.
  • Uses an easy bridge-based setup to work with optional measuring instruments, without opening the consumer.
  • Rated for 10 A and up to 2300 W, suitable for typical appliance verification tasks.
  • Designed for dry indoor operation only, with clear limits on humidity, dust, vibration, and magnetic fields.
  • Includes essential guidance on probe positioning and notes on special handling for current measurements.

Notes

  • For current measurements, the measuring bridge must be removed and your instrument connected in series.
  • An insulation tester is offered separately (mentioned in the instructions) for insulation checks.
  • Only qualified personnel should perform the intended electrical measurements and related work.
M: OA-GPT-54-NAN

© Copyright 2026 Manual.ly