EN NL FR DE ES IT
1. IMPORTANT SAFETY INSTRUCTIONS – SAVE
THESE INSTRUCTIONS!
In general
Please read the documentation supplied with this product first, so that you are familiar with the
safety signs en directions before using the product.
This product is designed and tested in accordance with international standards. The equipment
should be used for the designated application only.
Warning – These servicing instructions are for use by qualified
personnel only. To reduce the risk of electric shock, do not
perform any servicing other than that specified in the operating
instructions unless you are qualified to do so.
WARNING: ELECTRIC SHOCK HAZARD
The product is used in conjunction with a permanent energy source (battery). Input and/or output
terminals may still be dangerously energized, even when the equipment is switched off. Always
disconnect the battery before carrying out maintenance or servicing the product.
The product has no internal user-serviceable components. Do not remove the front plate or
operate the product if any panels have been removed. All servicing must be undertaken by
qualified personnel.
Please read the installation instructions in the installation manual before installing the equipment.
This is a Safety Class I product (supplied with a protective grounding terminal). The chassis must
be grounded. A grounding point is located on the outside of the product. Whenever it is likely that
the grounding protection has been damaged, the product must be turned off and secured against
unintended operation; please contact qualified service staff.
The AC output is isolated from the DC input and the chassis unless the unit is equipped with a
Ground Fault Circuit Interrupter (GFCI). Units with a GFCI have AC output neutral
connected to chassis inside the device by default. A qualified installer should check this
connection since it is necessary for the GFCI to function properly. Local regulations may
require a true neutral. In this case one of the AC output wires must be connected to the chassis,
and the chassis must be connected to a reliable ground. Please note that a true neutral is
needed to ensure correct operation of an earth leakage circuit breaker.
Ensure that the equipment is used under the correct ambient conditions.
Never operate the product in a wet or dusty environment.
Never use the product where there is a risk of gas or dust explosions.
Ensure there is adequate free space (10 cm) for ventilation around the product and check that the
ventilation vents are not blocked.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
Children should be supervised to ensure that they do not play with the appliance.
Use of an attachment not recommended or sold by the marine unit manufacturer may result in a
risk of fire, electric shock, or injury to persons.

Chat with your Victron Energy Phoenix Inverter VE.Direct manual using AI

Get instant AI answers from your Victron Energy Phoenix Inverter VE.Direct manual

Ask anything about the Victron Energy Phoenix Inverter VE.Direct. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend Phoenix Inverter VE.Direct?

Yes No

Frequently Asked Questions

A

It switches to standby when the load drops below a preset value. It wakes periodically to check for load increase. Default start power is 15 Watts. If power exceeds this, the inverter continues operation.

Is this answer helpful?

A

No. Never connect the output to another AC source like a wall outlet or generator. This can damage the device. The unit has no protection for AC output connections.

Is this answer helpful?

A

It is a communication port to connect to computers or smartphones for monitoring and configuring settings remotely. You need specific cables or dongles for Bluetooth connectivity.

Is this answer helpful?

A

The output voltage decreases to limit current. If exceeded continuously the unit shuts down and resets after 30 seconds. After three resets it will stay off until manual restart.

Is this answer helpful?

A

It depends on the model. Some fuses are replaceable while others are not and require service. Check the technical table for your specific variant to know the fuse type.

Is this answer helpful?

A

Mount securely on wall or floor. Keep 10cm ventilation space. Ground the chassis. Use correct cable cross sections. Avoid direct sunlight and moisture to ensure longevity.

Is this answer helpful?

A

Remove the cause of the fault. Switch off then switch back on. Wait for temperature to drop if it was caused by excessive heat or overload conditions.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Proven toroidal transformer topology ensures long term reliability for critical loads.
  • VE.Direct port allows easy monitoring and configuration via mobile app or computer.
  • Adjustable ECO mode reduces no load consumption effectively saving battery power daily.
  • Comprehensive protection against overload, high temperature, and low battery voltage conditions.
  • Wide input voltage range supports various battery systems up to 62 volts DC.
VS

Disadvantages

  • Internal DC fuses are not replaceable in certain lower wattage models permanently.
  • Requires strict grounding and correct neutral connection to chassis for safety compliance.
  • Ventilation clearance of 10 centimeters is mandatory to prevent overheating shutdowns.
  • High power models are heavy which complicates mounting in some mobile applications.
  • LED diagnostics require manual interpretation to identify specific fault codes accurately.
M: QW-35-FL

Product Specification

Input Voltage

12V DC

Input Voltage Range

9.2-17.3V

Output Voltage

230V AC Sine Wave

Inputs

1 x Terminals

Outputs

1 x AC Outlet

M: QW-35-FL

Product Description

Victron Energy Phoenix 12V VE.Direct Inverter Overview

Transforming direct current into alternating current is essential for many modern power systems. The Victron Energy Phoenix 12V VE.Direct Inverter provides a robust solution for off-grid and mobile applications. This device converts battery power efficiently into a clean sinusoidal output suitable for sensitive electronics. It is built for reliability in challenging conditions, ensuring your equipment stays powered during critical moments. Users will appreciate the stability it brings to their energy setup.

Connectivity and Configuration Options

A standout feature is the VE.Direct communication port. This allows users to connect their smartphones or tablets using the VictronConnect app for detailed insights. You can monitor battery voltage, AC output voltage, and load indicators in real time without extra hardware. Configuration is fully flexible to meet specific needs. You can adjust low battery voltage alarms, output voltage levels between 210 and 245 volts, and frequency settings for 50 or 60 Hz. This flexibility makes it adaptable to various regions and load requirements effectively.

Energy Efficiency and Safety Features

Efficiency is maintained with a proven toroidal transformer topology. The unit features an ECO mode to switch to standby when the load decreases significantly. This reduces power consumption substantially when devices are idle. Safety is paramount for all installations involved. The chassis must be grounded according to international standards to prevent hazards. Internal fuses protect against reverse polarity and short circuits automatically. Overload protection ensures the unit shuts down gracefully if demands exceed limits continuously.

Installation and Placement Guidelines

Proper placement is critical for longevity and optimal performance. Leave at least 10 centimeters of clearance for good ventilation around the unit. The ambient temperature should remain between minus 20 and 40 degrees Celsius for safe operation. Avoid dusty or wet environments completely. Do not mount the unit upside down if not approved. Internal fuses are not replaceable in all smaller models, so correct wiring sizing is essential to prevent damage. Always disconnect the battery before servicing.

Technical Performance Notes

The inverter handles peak power surges well for starting motors or lamps. It includes LED diagnostics for clear visual feedback on status and faults. A quick transfer switch can be added to integrate with other AC sources seamlessly. This ensures power continuity without interruption during switching events. The unit supports various output sockets for global compatibility. It is a solid choice for stable DC to AC conversion in demanding scenarios.

Summary of Benefits

This inverter balances performance with ease of use. Whether for marine, recreational, or home backup power, it delivers consistent sine wave output. The inclusion of remote connectivity enhances troubleshooting capabilities significantly. Users should consult safety instructions before installation to ensure compliance with local regulations and maintain warranty coverage. It remains a top choice for reliable inverter technology today.