e7ad9918d5f4bc79cf9d39b492b60ccc9c39 page 3
Copyrights 2008 Victron Energy B.V.
All Rights Reserved
This publication or parts thereof may not be reproduced in any form, by any method, for any
purpose.
For conditions of use and permission to use this manual for publication in other than the
English language, contact Victron Energy B.V.
VICTRON ENERGY B.V. MAKES NO WARRANTY, EITHER EXPRESSED OR IMPLIED, INCLUDING
BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, REGARDING THESE VICTRON ENERGY PRODUCTS AND MAKES SUCH
VICTRON ENERGY PRODUCTS AVAILABLE SOLELY ON AN ‘AS IS’ BASIS.
IN NO EVENT SHALL VICTRON ENERGY B.V. BE LIABLE TO ANYONE FOR SPECIAL, COLLATERAL,
INCIDENTAL, OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR ARISING OUT OF
PURCHASE OR USE OF THESE VICTRON ENERGY PRODUCTS. THE SOLE AND EXCLUSIVE
LIABILITY TO VICTRON ENERGY B.V., REGARDLESS OF THE FORM OF ACTION, SHALL NOT
EXCEED THE PURCHASE PRICE OF THE VICTRON ENERGY PRODUCTS DESCRIBED HERE IN.
Victron Energy B.V. reserves the right to revise and improve its products as it sees fit. This
publication describes the state of this product at the time of its publication and may not
reflect the product at all times in the future

Chat with your Victron Energy EasyPlus C 12/1600/70-16 manual using AI

Get instant AI answers from your Victron Energy EasyPlus C 12/1600/70-16 manual

Ask anything about the Victron Energy EasyPlus C 12/1600/70-16. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend EasyPlus C 12/1600/70-16?

Yes No

Frequently Asked Questions

A

It functions as a true sine-wave inverter, an adaptive multi-stage battery charger and a fast AC transfer switch in one unit, providing uninterrupted AC power and intelligent battery charging.

Is this answer helpful?

A

PowerAssist supplements a limited external AC source by briefly supplying extra power from the battery during peaks, letting you handle short surges without oversizing the generator or shore connection; spare power is then used to recharge the battery.

Is this answer helpful?

A

Adaptive 4-stage charging (bulk, absorption, float, storage), BatterySafe to limit gassing, storage mode to lower float voltage and weekly equalization, temperature compensation via included sensor, and bulk protection limiting long bulk times.

Is this answer helpful?

A

Yes — up to six identical units can be paralleled or configured for three-phase operation using RJ45 UTP interconnects; equal DC cable lengths, proper configuration via VEConfigure and, for more than three units, a dongle are required.

Is this answer helpful?

A

Use the front On/Off/Charger-Only switch and set it to 'charger only' when you want the charger active but prevent automatic inverter start on AC loss, avoiding battery depletion.

Is this answer helpful?

A

Install near batteries in a dry, well-ventilated area with at least 10 cm clearance, use correct cable cross-sections and fusing, ensure uninterrupted protective grounding, and have a qualified electrician perform the installation.

Is this answer helpful?

A

VEConfigureII or VE.Bus System Configurator software, an RJ45 UTP cable and the MK2.2b RS485-to-RS232 interface (or RS232-to-USB adapter) are required for full configuration; a dongle is needed for advanced systems with four or more units.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • Integrated inverter, adaptive charger and fast transfer switch for uninterrupted AC power and compact installation.
  • PowerControl and PowerAssist intelligently manage limited shore or generator power and support peak demands.
  • Adaptive 4-stage charging with BatterySafe and storage mode reduces gassing, stratification and battery aging.
  • Supports remote control, programmable relay, parallel and three-phase operation for flexible system design.
  • Comprehensive protections and configurability (DIP switches and VEConfigure software) for varied battery types.
VS

Disadvantages

  • Requires qualified installation and careful grounding to meet Safety Class I requirements.
  • Parallel or 3-phase setups demand identical units, equal cable lengths and extra configuration effort.
  • Starter output limited (~4 A), so an external starter alternator charger may be required for heavy starting needs.
  • Advanced features (VEConfigure, dongle for >3 units) add complexity and may require additional accessories.
  • Default charge current (75% of max) may be too high for many battery banks and should be adjusted.
M: OA-GPT-5-NAN

Product Specification

Note

Prices partially include 0%-VAT tax rates for AT and DE

Type

Battery Inverter

Input Voltage

9.5-17V DC voltage

Input Current max.

70A

Output Power

1.6kW

Output Phases

3-phase

Efficiency

92.0% max.

Protection Class

IP21

Ambient Temperature

-4°F to +122°F

Dimensions

8.43x20.08x4.33in (WxHxD)

Weight

25.81lb

M: OA-GPT-54-NAN

Product Description

Notes

  • Adaptive charging optimizes absorption time based on discharge depth; storage mode reduces float to 13.2 V (12 V system) and equalizes weekly.
  • PowerAssist can reduce generator sizing or increase usable shore power for short peaks.
  • Parallel/3-phase setups require identical units, equal DC cable lengths, and configuration via VEConfigure; systems over three units require a dongle.
  • Respect safety warnings: disconnect AC and battery before servicing and do not operate with panels removed.
  • Use the included battery temperature sensor for temperature-compensated charging, especially with sealed batteries.