Victron Energy EasyPlus C 12/1600/70-16 Manual
PDF manual · 150 Pages
English

Quick check
Incorrect answer, please try again.
Chat with your Victron Energy EasyPlus C 12/1600/70-16 manual using AI
Get instant AI answers from your Victron Energy EasyPlus C 12/1600/70-16 manual
Ask anything about the Victron Energy EasyPlus C 12/1600/70-16. Answers come from this manual, with the pages they are based on.
Ask a Question
Do you recommend EasyPlus C 12/1600/70-16?
Yes NoFrequently Asked Questions
It functions as a true sine-wave inverter, an adaptive multi-stage battery charger and a fast AC transfer switch in one unit, providing uninterrupted AC power and intelligent battery charging.
Is this answer helpful?
PowerAssist supplements a limited external AC source by briefly supplying extra power from the battery during peaks, letting you handle short surges without oversizing the generator or shore connection; spare power is then used to recharge the battery.
Is this answer helpful?
Adaptive 4-stage charging (bulk, absorption, float, storage), BatterySafe to limit gassing, storage mode to lower float voltage and weekly equalization, temperature compensation via included sensor, and bulk protection limiting long bulk times.
Is this answer helpful?
Yes — up to six identical units can be paralleled or configured for three-phase operation using RJ45 UTP interconnects; equal DC cable lengths, proper configuration via VEConfigure and, for more than three units, a dongle are required.
Is this answer helpful?
Use the front On/Off/Charger-Only switch and set it to 'charger only' when you want the charger active but prevent automatic inverter start on AC loss, avoiding battery depletion.
Is this answer helpful?
Install near batteries in a dry, well-ventilated area with at least 10 cm clearance, use correct cable cross-sections and fusing, ensure uninterrupted protective grounding, and have a qualified electrician perform the installation.
Is this answer helpful?
VEConfigureII or VE.Bus System Configurator software, an RJ45 UTP cable and the MK2.2b RS485-to-RS232 interface (or RS232-to-USB adapter) are required for full configuration; a dongle is needed for advanced systems with four or more units.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- Integrated inverter, adaptive charger and fast transfer switch for uninterrupted AC power and compact installation.
- PowerControl and PowerAssist intelligently manage limited shore or generator power and support peak demands.
- Adaptive 4-stage charging with BatterySafe and storage mode reduces gassing, stratification and battery aging.
- Supports remote control, programmable relay, parallel and three-phase operation for flexible system design.
- Comprehensive protections and configurability (DIP switches and VEConfigure software) for varied battery types.
Disadvantages
- Requires qualified installation and careful grounding to meet Safety Class I requirements.
- Parallel or 3-phase setups demand identical units, equal cable lengths and extra configuration effort.
- Starter output limited (~4 A), so an external starter alternator charger may be required for heavy starting needs.
- Advanced features (VEConfigure, dongle for >3 units) add complexity and may require additional accessories.
- Default charge current (75% of max) may be too high for many battery banks and should be adjusted.
Product Specification
Note
Prices partially include 0%-VAT tax rates for AT and DE
Type
Battery Inverter
Input Voltage
9.5-17V DC voltage
Input Current max.
70A
Output Power
1.6kW
Output Phases
3-phase
Efficiency
92.0% max.
Protection Class
IP21
Ambient Temperature
-4°F to +122°F
Dimensions
8.43x20.08x4.33in (WxHxD)
Weight
25.81lb
Product Description
Victron Energy EasyPlus C 12/1600/70-16 — Smart inverter/charger overview ## A versatile hybrid power solution The Victron Energy EasyPlus C 12/1600/70-16 combines a true sine-wave inverter, an adaptive multi-stage battery charger and a fast AC transfer switch in a compact, wall-mountable enclosure. Designed for mobile and stationary applications, it provides uninterrupted AC power (switching in under 20 ms) and advanced power management features that let you maximize limited shore or generator power while protecting batteries. ## Key capabilities and how they help PowerControl lets you cap generator or shore current so the EasyPlus only uses spare capacity for charging, avoiding overloads. PowerAssist can actively supplement a weak shore or generator source by drawing short bursts from the battery to cover peaks, then replenishing the battery when load decreases. The adaptive four-stage charger (bulk, absorption, float, storage) automatically adjusts absorption time to match battery use — reducing gassing and aging after shallow cycles and extending absorption after deep discharges. BatterySafe limits voltage rise when gassing voltage is reached, and storage mode reduces float voltage during long idle periods with weekly equalization to prevent stratification and sulphation. Two charger outputs support house and starter batteries (starter output is limited to ≈4 A). Temperature compensation via the included sensor helps protect sealed batteries. ## Operation and control The front-panel On/Off/Charger-Only switch lets you choose inverter+charger, inverter or charger-only modes; charger-only prevents inverter startup if mains is lost, protecting batteries from deep discharge. Remote control is supported via a 3‑way switch or a Digital Multi Control panel, permitting AC input current limits to be set (for PowerControl/PowerAssist) and enabling forced absorption or equalization sequences. A programmable relay (default alarm) can be reconfigured for tasks such as generator start. Parallel and 3‑phase configurations are supported (up to six identical units in parallel; RJ45 interconnects) with software configuration for advanced setups. ## Installation and safety notes Install in a dry, well-ventilated area near batteries, allow at least 10 cm clearance for cooling, and follow wiring, grounding and fuse recommendations. Use appropriately sized battery cables to minimize voltage drop, observe polarity, and connect protective grounding. The unit is Safety Class I and requires qualified installation. ## Maintenance and troubleshooting Minimal maintenance is required—periodic inspection of connections is recommended. Built-in protections include overload, short-circuit, over/under battery voltage, temperature, and excessive input ripple. Detailed LED indications, DIP-switch and software-configurable settings allow field tuning of charge voltages, absorption times, frequency selection, input current limits, UPS behavior and more. ## Final thought The EasyPlus C 12/1600/70-16 is a full-featured hybrid inverter/charger that blends adaptive battery care with intelligent power-sharing features, making it well-suited for boats, mobile homes, off-grid cabins and small renewable or backup systems where space, reliability and battery longevity matter.
Notes
- Adaptive charging optimizes absorption time based on discharge depth; storage mode reduces float to 13.2 V (12 V system) and equalizes weekly.
- PowerAssist can reduce generator sizing or increase usable shore power for short peaks.
- Parallel/3-phase setups require identical units, equal DC cable lengths, and configuration via VEConfigure; systems over three units require a dongle.
- Respect safety warnings: disconnect AC and battery before servicing and do not operate with panels removed.
- Use the included battery temperature sensor for temperature-compensated charging, especially with sealed batteries.