Manual.ly Logo

T.I.P. Maxima 350 IPX DUO Manual

0.0 · 0 Ratings

PDF manual · 84 Pages

English

M: gpt-5.6-terra
page

/ 84

Loading...
6ef19454d8298e2885f90777405b4e319d79 page e
1
Dear customer,
Congratulation for buying your new device from T.I.P.!
Like all our products, this one, too, was developed using the latest technological knowledge.
The device was manufactured and assembled on the basis of state-of-the-art pump
technology using most reliable electrical or electronic components which ensure a high level
of quality and a long life of your new product. Please read through these operating
instructions carefully to make sure that you can fully benefit from all features. Some
explanatory illustrations can be found at the end of these operating instructions.
We hope you will enjoy your new device!
Table of contents
1. General safety information ............................................................................................. 1
2. Range of use ................................................................................................................. 2
3. Technical Data ............................................................................................................... 2
4. Scope of delivery ........................................................................................................... 3
5. Installation ..................................................................................................................... 3
6. Electrical conection ........................................................................................................ 7
7. Putting into operation ..................................................................................................... 7
8. Maintenance and troubleshooting .................................................................................. 7
9. Warranty ........................................................................................................................ 9
10. How to order spare parts ..............................................................................................10
11. Service .........................................................................................................................10
1. General safety information
Please read through these operating instructions carefully and make yourself conversant with
the control elements and the proper use of this product. We shall not be liable in the case of
damage caused as a result of the nonobservance of instructions and provisions of the
present operating instructions. Any damage caused as a result of the nonobservance of the
instructions and regulations contained in the present operating instructions shall not be
covered by the warranty terms. Please keep these operating instructions in a safe place and
hand them on together with the device should you ever dispose of it.
Persons not conversant with the contents of these operating instructions must
not use this device.
The pump must not be used by children.
The pump may be used by persons with reduced physical, sensory or mental
capabilities or lack of experience and / or knowledge if they have been
supervised or instructed in the safe use of the equipment and have understood
the resulting hazards.
Children are not allowed to play with the device.
The pump must not be used when people or animals are in the water.
The pump must be supplied through a residual current device (RCD) having a
rated residual operating current not exceeding 30mA.
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
Notes and instructions with the following symbols require particular attention:
12

Chat with your T.I.P. Maxima 350 IPX DUO manual using AI

Get instant AI answers from your T.I.P. Maxima 350 IPX DUO manual

Ask anything about the T.I.P. Maxima 350 IPX DUO. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend Maxima 350 IPX DUO?

Yes No

Frequently Asked Questions

A

It is suitable for draining cellars, ponds, tanks, basins, dirty-water pits, rainwater areas, and flooded spaces. It can be used for temporary or fixed domestic installations, provided the liquid and operating conditions stay within its stated limits.

Is this answer helpful?

A

The pump has a maximum flow rate of 20,000 litres per hour when used with a free, unrestricted outlet. Actual flow can be lower depending on hose diameter, hose length, lift height, bends, and restrictions in the discharge line.

Is this answer helpful?

A

Yes. With the pump foot adjusted to dirty-water mode, it can handle solid particles up to 30 mm. Avoid sand, mud, and abrasive material where possible, as these can accelerate wear and reduce pumping performance.

Is this answer helpful?

A

In clear-water mode with manual float operation, it can reduce the remaining water level to about 1 mm. In dirty-water mode, the minimum suction level is about 35 to 40 mm. Manual operation requires continuous monitoring.

Is this answer helpful?

A

Yes. Its float switch starts the pump as water rises to the selected cut-in level and stops it as water falls to the cut-out level. The free cable length can be adjusted to change these operating levels.

Is this answer helpful?

A

Use a properly earthed 230 V AC supply protected by a residual current device rated at no more than 30 mA. Keep plug connections in a flood-safe area and inspect the power cable and plug before each use.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • Moves up to 20,000 l/h, supporting rapid drainage of flooded or water-filled areas.
  • Adjustable base supports both near-dry clear-water removal and dirty-water pumping with solids up to 30 mm.
  • Manual mode can reduce clear-water residue to approximately 1 mm.
  • Adjustable float switch enables automatic start and stop based on water level.
  • Includes a 10 m cable and multi-size connector for flexible installation options.
VS

Disadvantages

  • Designed for private domestic use, not commercial, industrial, or continuous-duty operation.
  • Manual low-level drainage requires constant supervision to prevent dry running.
  • Not suitable for saltwater, sewage, drinking water, or hazardous liquids.
  • Maximum pumped-liquid temperature is limited to 35 C.
  • Sand and abrasive debris can increase wear and reduce performance.
M: gpt-5.6-terra

Product Specification

Features

tankless

Cable length

32.81 ft

M: gpt-5.6-terra

Product Description

T.I.P. Maxima Electric Dirty Water Submersible Pump - Powerful Drainage for Home Use

The T.I.P. Maxima Electric Dirty Water Submersible Pump - Read, Download & Print Free is designed for dependable water removal in demanding domestic drainage tasks. Built for clean-water and dirty-water applications, this versatile submersible pump is suited to emptying flooded cellars, ponds, tanks, collection pits, basins, and rainwater-filled areas. Its dual operating design helps homeowners adapt the pump to changing cleanup and drainage needs.

Strong Performance for Dirty Water

Powered by an 800 W motor, the Maxima 350 IPX DUO can move up to 20,000 litres of water per hour under free-flow conditions. It offers a maximum delivery head of 8 metres and can be submerged to depths of up to 7 metres. In dirty-water mode, the adjustable pump base allows solids up to 30 mm to pass through, making it useful where leaves, grit, and other small debris may be present.

The pump is intended for private household use rather than industrial work or continuous circulation. It should not be used with saltwater, sewage, flammable liquids, corrosive substances, explosive liquids, or drinking water. The pumped liquid must not exceed 35 C.

Adjustable Base for Clear or Dirty Water

A key feature is the adjustable pump foot. In clear-water mode, the pump can remove water down to a residual level of approximately 1 mm when operated manually. This makes it a practical choice for near-dry floor drainage after leaks or flooding. Switching to dirty-water mode raises the pump base and supports particles up to 30 mm, with a minimum suction level of about 35 to 40 mm.

An integrated float switch provides automatic operation based on the water level. The cable length can be adjusted to alter the start and stop points. For very low-level drainage, the float can be secured for manual operation, but the pump must then be watched continuously to prevent dry running.

Installation and Everyday Safety

The pump includes a 10 m connection cable, a connection bend, and a multi-size connector for common hose and threaded connections. A pressure line with a diameter at least equal to the pump outlet is recommended for efficient flow. For fixed installations, a non-return valve and shut-off valve can help prevent backflow and simplify maintenance.

For safe operation, connect the pump to a properly earthed 230 V supply protected by a 30 mA residual current device. Place it on firm ground, keep the float switch unobstructed, and never lift the unit by its cable or hose.

Note: Clean the hydraulic section when needed, protect the pump from frost, and store it dry after draining. The integrated thermal motor protection helps guard against overload, but blockages and dry running should always be avoided.