Manual.ly Logo

T.I.P. Extrema Series Manual

0.0 · 0 Ratings

PDF manual · 36 Pages

English

M: gpt-5.6-terra
page

/ 36

Loading...
29095a413c42b7eb8cc3d758ac74adcf02d3 page a
Translation of the Original Operating Instructions
1
Dear customer,
Congratulation for buying your new device from T.I.P.!
Like all our products, this one, too, was developed using the latest technological knowledge. The device was
manufactured and assembled on the basis of state-of-the-art pump technology using most reliable electrical or
electronic components which ensure a high level of quality and a long life of your new product.
Please read through these operating instructions carefully to make sure that you can fully benefit from all features.
Some explanatory illustrations can be found at the end of these operating instructions.
We hope you will enjoy your new device!
Table of contents
1. General safety information ............................................................................................................................. 1
2. Technical Data ............................................................................................................................................... 2
3.
Range of use .................................................................................................................................................. 2
4.
Scope of delivery ........................................................................................................................................... 2
5.
Installation ...................................................................................................................................................... 3
6. Electrical connection ...................................................................................................................................... 3
7.
Putting into operation ..................................................................................................................................... 4
8.
Maintenance and troubleshooting .................................................................................................................. 4
9.
Warranty ........................................................................................................................................................ 6
10. How to order spare parts ................................................................................................................................ 6
11.
Service ........................................................................................................................................................... 6
Annex: Illustrations
1. General safety information
Please read through these operating instructions carefully and make yourself conversant with the control
elements and the proper use of this product. We shall not be liable in the case of damage caused as a result of
the nonobservance of instructions and provisions of the present operating instructions. Any damage caused as a
result of the nonobservance of the instructions and regulations contained in the present operating instructions
shall not be covered by the warranty terms. Please keep these operating instructions in a safe place and hand
them on together with the device should you ever dispose of it.
Persons not conversant with the contents of these operating instructions must not
use this device.
The pump must not be used by children.
The pump may be used by persons with reduced physical, sensory or mental
capabilities or lack of experience and / or knowledge if they have been supervised or
instructed in the safe use of the equipment and have understood the resulting
hazards. Children are not allowed to play with the device. Keep the appliance and its
cord out of reach of children.
The pump must not be used when people or animals are in the water.
The pump must be supplied through a residual current device (RCD) having a rated
residual operating current not exceeding 30mA.
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
Notes and instructions with the following symbols require particular attention:
Any nonobservance of these instructions involves the danger of bodily harm to people and/or
damage to property.
Any nonobservance of this instruction bears the risk of an electrical shock which may cause
damage to persons or property.
Please inspect the device for damage occurred during transportation. In case of damage, the retailer has to be
informed immediately, at the latest within 8 days after the date of purchase.
8

Chat with your T.I.P. Extrema Series manual using AI

Get instant AI answers from your T.I.P. Extrema Series manual

Ask anything about the T.I.P. Extrema Series. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend Extrema Series?

Yes No

Frequently Asked Questions

A

The pump has a maximum flow rate of 18,000 litres per hour with a free, unrestricted outlet. Actual output can vary with hose diameter, lift height, bends, restrictions, and the condition of the pumped liquid.

Is this answer helpful?

A

It can pump clear or dirty water containing solids up to 50 mm. Its cutting system is suitable for fibrous or solid-containing water and domestic wastewater without feces. It must not be used with saltwater, feces, or hazardous liquids.

Is this answer helpful?

A

Yes. An adjustable float switch starts the pump as water rises and stops it as the level falls. The default cut-in level is 550 mm and the cut-out level is 215 mm. Ensure the float has enough space to move freely.

Is this answer helpful?

A

In supervised manual operation with the float switch secured upright, the pump can reach a minimum suction level of 70 mm. Never leave it unattended in this mode, because dry running can overheat and damage the pump.

Is this answer helpful?

A

For normal use, the maximum liquid temperature is 35 C. When fully submerged, it can handle up to 50 C. Water from 50 C to 90 C is allowed only for a maximum of four minutes before cooling is required.

Is this answer helpful?

A

Connect the pump to a grounded 230 V, 50 Hz supply protected by a residual current device with a rated residual operating current no higher than 30 mA. Keep plugs and electrical connections in a flood-safe location.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • High 18,000 l/h maximum flow rate supports fast drainage of ponds, tanks, pits, and flooded areas.
  • 2,000 W motor and 18 m maximum delivery head provide strong pumping performance.
  • Cutting system and 50 mm solids capacity help manage fibrous and particle-laden dirty water.
  • Adjustable float switch enables automatic level control and supervised low-level drainage.
  • Integrated thermal protection and IPX8 rating support dependable submerged operation.
VS

Disadvantages

  • At about 21.1 kg, the pump is relatively heavy to move and position.
  • Manual float-switch operation must be watched continuously to avoid dry running.
  • Water above 50 C can only be pumped for up to four minutes when fully submerged.
  • Not suitable for saltwater, feces, flammable, corrosive, explosive, or hazardous liquids.
  • The cutting unit requires professional fixed installation for safety in applicable installations.
M: gpt-5.6-terra

Product Specification

Features

tankless

Cable length

32.81 ft

M: gpt-5.6-terra

Product Description

T.I.P. Extrema Electric Dirty Water Submersible Pump - Read, Download & Print Free

The T.I.P. Extrema Electric Dirty Water Submersible Pump is a heavy-duty drainage solution designed for demanding domestic and property-maintenance jobs. Built for moving clear or dirty water containing solids, this model combines a powerful 2,000 W motor with a cutting system that helps handle fibrous material and particle-laden wastewater. It is a practical choice for clearing ponds, tanks, collection pits, flooded basements, and other areas where rapid water removal matters.

Strong Performance for Dirty-Water Tasks

The EXTREMA CUT 300/18 CX delivers a maximum flow rate of 18,000 litres per hour and can lift water up to 18 metres. Its 2-inch pressure outlet supports efficient discharge connections, while the supplied multi-size connector offers flexible hose options. The pump can process solids up to 50 mm, making it suited to tougher drainage conditions than a standard clean-water pump.

A maximum immersion depth of 7 metres broadens its installation possibilities. With an IPX8 protection rating and a 10 m H07RN8-F connection cable, the unit is engineered for submerged operation when installed and used correctly. At approximately 21.1 kg, it has a substantial build intended for stable positioning on firm ground.

Automatic Water-Level Control

An adjustable float switch starts and stops the pump according to the water level. The normal cut-in level is 550 mm and the cut-out level is 215 mm, while cable adjustment allows the switching range to be tailored to the installation. For deeper drainage, the float can be secured for manual operation, allowing a minimum suction level of 70 mm. Manual operation requires continuous supervision to prevent dry running.

The pump includes integrated thermal motor protection that shuts the motor down during overload and restarts it after cooling. It is rated for continuous operation when the motor is submerged. Water temperatures up to 50 C are permitted when fully submerged, while temperatures up to 90 C are limited to a maximum of four minutes.

Installation and Care Notes

For fixed installations, rigid pipework, a non-return valve, and an isolation valve are recommended to reduce backflow and simplify maintenance. Use a residual current device rated at no more than 30 mA, keep electrical connections above flood level, and never lift the pump by its cable or hose.

Note: This pump is not intended for swimming pools, public drinking-water systems, saltwater, feces, flammable liquids, corrosive liquids, explosive liquids, or hazardous media. Position it on a solid surface and protect it from frost during storage.