Manual.ly Logo

T.I.P. DrainPress 3200/24 Manual

0.0 · 0 Ratings

PDF manual · 140 Pages

English

M: gpt-5.6-terra
page

/ 140

Loading...
8b3ec47dff01d431a0234fdf2cbd8047e0be page c
1
Dear customer,
Congratulation for buying your new device from T.I.P.!
Like all our products, this one, too, was developed using the latest technological knowledge. The
device was manufactured and assembled on the basis of state-of-the-art pump technology using most
reliable electrical or electronic components which ensure a high level of quality and a long life of your
new product.
Please read through these operating instructions carefully to make sure that you can fully benefit from
all features.
Some explanatory illustrations can be found at the end of these operating instructions.
We hope you will enjoy your new device!
Table of contents
1. General safety information ............................................................................................................................. 1
2. Range of use .................................................................................................................................................. 2
3. Technical Data ............................................................................................................................................... 2
4. Scope of delivery ........................................................................................................................................... 3
5. Installation ...................................................................................................................................................... 3
6. Electrical connection ...................................................................................................................................... 4
7. Putting into operation ..................................................................................................................................... 5
8. Maintenance and troubleshooting .................................................................................................................. 5
9. Warranty ........................................................................................................................................................ 7
10. How to order spare parts ................................................................................................................................ 8
11. Service ........................................................................................................................................................... 8
Annex: Illustrations
1. General safety information
Please read through these operating instructions carefully and make yourself conversant with the
control elements and the proper use of this product. We shall not be liable in the case of damage
caused as a result of the nonobservance of instructions and provisions of the present operating
instructions. Any damage caused as a result of the nonobservance of the instructions and regulations
contained in the present operating instructions shall not be covered by the warranty terms. Please
keep these operating instructions in a safe place and hand them on together with the device should
you ever dispose of it.
Persons not conversant with the contents of these operating instructions must not
use this device.
The pump must not be used by children.
The pump may be used by persons with reduced physical, sensory or mental
capabilities or lack of experience and / or knowledge if they have been supervised or
instructed in the safe use of the equipment and have understood the resulting
hazards.
Children are not allowed to play with the device.
Keep the appliance and its cord out of reach of children.
The pump must not be used when people or animals are in the water.
The pump must be supplied through a residual current device (RCD) having a rated
residual operating current not exceeding 30mA.
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
Disconnect the device from the power supply and let it cool down before cleaning
and maintenance is performed and before the device is stored.
Notes and instructions with the following symbols require particular attention:
10

Chat with your T.I.P. DrainPress 3200/24 manual using AI

Get instant AI answers from your T.I.P. DrainPress 3200/24 manual

Ask anything about the T.I.P. DrainPress 3200/24. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend DrainPress 3200/24?

Yes No

Frequently Asked Questions

A

It is designed for clear, clean, or moderately dirty water with solids up to 2 mm. It must not be used for saltwater, sewage, flammable, corrosive, explosive, or other hazardous liquids.

Is this answer helpful?

A

The pump uses a 400 W motor and can deliver up to 3,200 l/h. Its maximum pressure is 2.4 bar and its maximum delivery head is 24 m. Maximum submersion depth is 7 m.

Is this answer helpful?

A

Yes. Its float switch starts the pump when water reaches the selected cut-in level and stops it at the cut-out level. The free cable length can be adjusted to change these levels.

Is this answer helpful?

A

With the dirt guard installed, the minimum suction level is 4 mm. With the guard removed, it can reach 1 mm, but only with clear water, manual float-switch operation, and continuous supervision.

Is this answer helpful?

A

The guard helps prevent dirt from entering the pump and damaging or blocking the impellers. Removing it is only recommended for low-level drainage of clear water with particles no larger than 0.5 mm.

Is this answer helpful?

A

The pump requires a 230 V, 50 Hz supply with proper grounding. It must be connected through an RCD or residual-current device with a rated residual operating current of no more than 30 mA.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • Delivers up to 3,200 l/h with a maximum pressure of 2.4 bar and a 24 m delivery head.
  • Adjustable float switch enables automatic operation based on the water level.
  • Low-level drainage reaches 4 mm with the guard fitted and 1 mm in supervised manual mode.
  • Suitable for pools, tanks, cisterns, room drainage, sprinklers, and garden watering.
  • Integrated thermal motor protection and a 10 m connection cable support practical operation.
VS

Disadvantages

  • Intended for private household use, not commercial, industrial, or continuous circulation duties.
  • Cannot pump saltwater, sewage, flammable, corrosive, explosive, or hazardous liquids.
  • Manual low-level operation needs continuous supervision to prevent dry running.
  • Removing the dirt guard reduces maximum flow by about 30% and limits particles to 0.5 mm.
  • Pumped liquid temperature must not exceed 35 C, and solids must not exceed 2 mm.
M: gpt-5.6-terra

Product Specification

Power

400 W

Flow rate

845.35 gal/h

Delivery head

78.74 ft

Suction height

29.53 ft

Pressure

34.81 psi

Pressure connection

3/4 in

Special features

without tank

Cable length

32.81 ft

Weight

10.36 lb

M: gpt-5.6-terra

Product Description

T.I.P. DrainPress 3200/24 Electric Submersible Pressure Pump - Read, Download & Print Free

The T.I.P. DrainPress 3200/24 Electric Submersible Pressure Pump is a compact, multi-stage pump designed for practical water transfer, drainage, and irrigation jobs around the home. With a 400 W motor, a maximum flow rate of 3,200 l/h, and pressure up to 2.4 bar, it is built to move water efficiently where dependable pressure is needed.

Its maximum delivery head of 24 m makes it suitable for supplying sprinklers, spray nozzles, and other garden watering setups. The pump can also help empty pools, tanks, cisterns, and water-filled rooms. A 3/4-inch male pressure connection and included quick coupling support straightforward connection to a garden hose.

Automatic operation and low-level drainage

A built-in float switch starts and stops the pump according to the water level. The switch cable can be adjusted to alter the cut-in and cut-out points, giving users flexibility for different containers and drainage tasks. For applications that require more complete water removal, the float switch can be secured for manual operation.

The DrainPress 3200/24 can reach a minimum suction level of 4 mm with the dirt guard fitted. For very shallow residual water, removing the guard allows suction down to 1 mm. This mode is intended only for clear water with particles no larger than 0.5 mm, requires constant supervision, and reduces maximum flow by about 30%.

Designed for everyday water handling

The pump is intended for clear, clean, or moderately dirty water containing particles up to 2 mm. It can be submerged to a maximum depth of 7 m and handles liquids up to 35 C. Its IPX8 protection rating, 10 m H05RN-F connection cable, and integrated thermal motor protection support reliable use in suitable wet environments.

For fixed installations, a non-return valve and shut-off valve are recommended to limit backflow and make maintenance easier. The unit should stand on firm ground, away from loose sand, stones, and sludge that could obstruct the intake. A carrying handle provides the correct point for moving or lowering the pump.

Important notes

  • Use an RCD rated at no more than 30 mA.
  • Never operate the pump while people or animals are in the water.
  • Do not pump saltwater, sewage, flammable, corrosive, explosive, or hazardous liquids.
  • Prevent dry running, especially when the float switch is locked for manual operation.
  • Disconnect the power before cleaning, maintenance, storage, or troubleshooting.
M: gpt-5.6-terra

© Copyright 2026 Manual.ly